For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 38.520.060 — Building materials

Bozeman Municipal Code, City of Bozeman, Montana (Codified through Order No. 2026-11, adopted September 15, 2026. (Supp. No. 16, Update 1)) · Bozeman Municipal Code § 38.520.060

Corpus is an independent public-information project, not the official City of Bozeman website. Stable reference: corpuslaw.us/code/66500085-edc3-4782-8694-1918e9852e50

Sec. 38.520.060. - Building materials.

A. Purpose. To encourage the use of durable materials to provide visual interest from vehicular and pedestrian vantage points with the highest priority at locations susceptible to damage from maintenance and weathering. B. Durable building materials. Applicants must use durable materials. Where facades are located directly adjacent to a city sidewalk, impact resistant materials must be used (excluding window and door areas) for a minimum of the first 18 inches above the walking surface. C. Special conditions and limitations for the use of certain cladding materials. 1. Concrete block (a.k.a. CMU). When used as a primary cladding material, concrete block must be treated or articulated to provide visual interest above and beyond natural (uncolored, untreated) block with (matching) natural colored grout. Examples of such treatments include: a. Using ground, polished or split face units; b. Creating patterns/texture with different block sizes, face treatments, or colors; creating patterns/textures by modulating the finish plane of units; c. Utilizing contrasting grout color; or d. Utilizing sealers or painted treatments that enhance the finish of natural concrete block. Industrial zoning districts are exempt from this subsection C. [image omitted; see the official code] Figure 38.520.060-1. Acceptable concrete block use/design. 2. Metal siding. a. Metal siding must be a minimum 24 gauge thickness. Re-purposed metal siding is exempt from minimum thickness requirements provided its material integrity is intact. b. Metal siding must feature appropriate molding, trim, or hemming at all exposed edges and corners. c. Metal siding must be factory finished, or alternately purposefully designed to naturally patina. Highly reflective galvanized finished are prohibited. Re-purposed or re-claimed metal siding is permitted. [image omitted; see the official code] Figure 38.520.060-2. Acceptable metal siding examples. 3. Standards for the use of exterior insulation and finish system (EIFS). Such material/finishes may be used as a decorative accent cladding material if it is incorporated with other permitted materials and it complies with the following: a. On buildings of three or more stories or 5,000 square feet in footprint or greater EIFS is limited to no more than 25 percent of the total facade area and is not the primary cladding material. On buildings of two stories or less or less than 5,000 square feet in footprint, EIFS is limited to 60 percent of the total facade area; b. Highly textured EIFS finishes are prohibited; c. EIFS must include an integrated joint or trim pattern; d. EIFS must not be used on the ground floor when directly adjacent to a sidewalk, pedestrian or vehicular pathway. Departures will be considered provided the material's integration and overall facade composition meets the purpose of the standards. [image omitted; see the official code] Figure 38.520.060-3. Acceptable and unacceptable EIFS examples. 4. Cementitious wall board paneling/siding may be used provided it meets the following provisions: a. Cement board paneling/siding may not be used on the ground floor of non-residential or mixed-use buildings where adjacent to a sidewalk or other pedestrian path; b. Where cement board paneling/siding is the dominant siding material, the design must integrate a mix of colors and/or textures that are articulated consistent with windows, balconies, and modulated building surfaces and are balanced with facade details that add visual interest from the ground level and adjacent buildings. Departures will be considered provided the material's integration and overall facade composition meets the purpose of the standards. D. Departures. Departures to building materials standards will be considered if they are determined to meet the purpose of this section.

(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)

Ask a question about Bozeman law

Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.