For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 38.520.080 — Structured parking facilities

Bozeman Municipal Code, City of Bozeman, Montana (Codified through Order No. 2026-11, adopted September 15, 2026. (Supp. No. 16, Update 1)) · Bozeman Municipal Code § 38.520.080

Corpus is an independent public-information project, not the official City of Bozeman website. Stable reference: corpuslaw.us/code/4d632eb6-56d1-4023-875e-d945b21077ef

Sec. 38.520.080. - Structured parking facilities.

A. Applicability. All above ground structured parking facilities must conform to the following design standards. B. Exceptions. 1. Single-/two-unit dwellings, three-unit dwellings, four-unit dwellings, individual townhouses, accessory garage structures not adjacent to the street, and multi-unit dwellings with physically separated individual drive aisles. Physical separation is provided when at least one of these options are provided: Individual garage doors for each interior parking space; a vegetated planter not less than four feet in width between the parking spaces in the driveway area; or a wall not less than four feet in height and length, is provided between the parking area in the driveway and dividing the garage entrance; and 2. For development in the R-D and B-2M districts, the structured parking provisions take precedence over any conflicting provisions of 38.240.020. C. Building standards. 1. To promote an active and diverse streetscape, parking structures must be located behind buildings in the interior of blocks or below grade. Parking garages that front streets must line the parking garage at the street level with an active use. a. Street designs accommodate on street parking and pedestrian mobility. Parking lots and garages rarely front the streets, and are typically relegated to the rear of the lot and the center of blocks. b. Parking garages should be located in the interior of blocks. Parking garages that front onto streets must provide a lining of retail, office, or residential use at the street level along the entire street frontage. 2. In all districts, all commercial floor space wrapping must provide a minimum 20 foot depth of habitable and conditioned space as defined by the most currently adopted IBC. 3. In all districts, commercial space depth will be considered where the applicant can successfully demonstrate the proposed alternative design and configuration of the space is viable for a variety of permitted commercial uses. 4. In all districts, residential active use areas must be 12 feet in depth, except for riser room, trash areas and other functional uses that must face the street. 5. In all districts, all commercial floor space wrapping a parking structure on the ground floor must have a minimum floor-to-floor height of 15 feet. 6. Structured parking facilities must provide transparency along at least 50 percent of the linear length of the building's facade. This may be achieved with windows, displays, building lobbies, building entrances, display windows, or windows affording views into the building. This requirement applies to both frontages of a building located on a corner lot. a. The bottom edge of any window or product display window used to satisfy the transparency standard may not be more than four feet above the adjacent sidewalk. b. Product display windows used to satisfy these requirements must have a minimum height of four feet and be internally lighted. 7. Street-level openings on parking structures must be limited to those necessary for retail store entrances, vehicle entrance and exit lanes, and pedestrian entrances to stairs and elevator lobbies. Parking structures adjacent to streets must have architectural detailing such as, but not limited to, standard size masonry units such as brick, divided openings to give the appearance of windows, and other techniques to provide an interesting and human-scaled appearance on the story adjacent to the sidewalk. 8. Buildings must be articulated with modules, architectural detailing, individual floors visually expressed in the facade, and rhythm and pattern of openings and surfaces must be human-scale. 9. Buildings must be oriented to the adjacent public or private street. 10. If an alley is adjacent to a site, vehicle access must be taken from that alley. Access to a street in lieu of an alley may be approved by the review authority. To approve street access the review authority must consider adequacy of right-of-way width of the alley and street, ability to obtain additional right-of-way if current right-of-way does not meet city standards, sight access entering and exiting the alley, volume of pedestrian and vehicle traffic at the site after proposed construction would be completed, proximity to other intersections and street accesses, ability to mitigate conflicts between pedestrians and vehicles, and potential interference with other municipal standards and criteria. Approval of street access may be approved upon a finding that the balance of public benefits weighs in favor of the street access. The department of transportation and engineering must evaluate the application for the identified considerations and make a recommendation to the review authority. 11. A pedestrian safety plan is required for all parking facilities with more than 100 parking spaces and must be reviewed and approved by the city engineer. The city engineer may request a pedestrian safety plan for parking facilities with less than 100 parking spaces. 12. Parking entrances may not account for more than 25 percent of entire building facade. D. Relief. Relief to the standards of paragraph C may be granted upon the application demonstrating an equal or superior outcome to the listed standard.

(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)

Ask a question about Bozeman law

Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.