§ 6.4.3 — Provisions for Flood Hazard Reduction
Code of Ordinances of the City of High Point, North Carolina (Codified through Ordinance No. 8067/25-45, enacted November 17, 2025 (Supp. No. 9)) · High Point Development Ordinance § 6.4.3
Corpus is an independent public-information project, not the official City of High Point website. Stable reference: corpuslaw.us/code/a8bacb6b-a601-449f-87cd-93b35fe3b156
6.4.3. - Provisions for Flood Hazard Reduction
A. General Standards Compliance with the following standards shall be required within a special flood hazard area: 1. New construction and substantial improvements in special flood hazard areas shall: (a) Be designed (or modified) and adequately anchored to prevent flotation, collapse, and lateral movement of the structure; (b) Be constructed with materials and utility equipment resistant to flood damage; (c) Be constructed by methods and practices that minimize flood damages; (d) Be designed so that electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities are configured to prevent water from entering or accumulating within the components during conditions of flooding to the regulatory flood protection elevation. These include, but are not limited to: (1) HVAC equipment; (2) Water softener units; (3) Bath/kitchen fixtures; (4) Ductwork; (5) Electric/gas meter panels/boxes; (6) Utility/cable boxes; (7) Hot water heaters; and (8) Electric outlets/switches; (e) Be designed so that new and replacement water supply systems minimize or eliminate infiltration of floodwaters into the system; (f) Be designed so that new and replacement sanitary sewage systems minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters; (g) Be located and constructed to avoid impairment of on-site waste disposal systems or contamination from them during flooding; 2. Any alteration, repair, reconstruction, or improvements to a structure, which is in compliance with the provisions of this section, shall comply with the requirements of "new construction" as established in this section; 3. Nothing in this section shall prevent the repair, reconstruction, or replacement of a building or structure existing on the effective date of this Ordinance and located totally or partially within the floodway, non-encroachment area, or stream setback, provided there is no additional encroachment below the regulatory flood protection elevation in the floodway, non-encroachment area, or stream setback, and provided that such repair, reconstruction, or replacement meets all of the other requirements of this section; 4. New solid waste disposal facilities and sites, hazardous waste management facilities, salvage yards, and chemical storage facilities shall not be permitted in the special flood hazard area; 5. A structure or tank for chemical or fuel storage incidental to an allowed use or to the operation of a water treatment plant or wastewater treatment facility may be located in a special flood hazard area only if the structure or tank is either elevated or floodproofed to at least the regulatory flood protection elevation and certified in accordance with the provisions of Section 6.4.2 B, Certification Requirements; 6. Subdivision and other development applications shall: (a) Be consistent with the need to minimize flood damage; (b) Require public utilities and facilities such as sewer, gas, electrical, and water systems located and constructed to minimize flood damage; (c) Require adequate drainage provided to reduce exposure to flood hazards; and (d) Receive all necessary permits from those governmental agencies for which approval is required by federal or state law, including Section 404 of the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1334. 7. When a structure is partially located in a special flood hazard area, the entire structure shall meet the requirements for new construction and substantial improvement. 8. When a structure is located in multiple flood hazard zones or in a flood hazard risk zone with multiple base flood elevations, the provisions for the more restrictive flood hazard risk zone and the highest base flood elevation shall apply. B. Specific Standards In addition to the standards in Section 6.4.3 A, General Standards, development in all special flood hazard areas where base flood elevation (BFE) data has been provided, as set forth in Section 6.4.1 B, Basis for Establishing Special Flood Hazard Areas, or Section 6.4.3 C, Standards for Floodplains without Established Base Flood Elevations, shall be subject to the following: 1. Non-Residential Construction (a) New construction and substantial improvement of a nonresidential structure shall have the reference level, including basement, elevated no lower than the regulatory flood protection elevation, as established in this section. (b) A structures located in A, AE, AO, and A1-30 Zones may be floodproofed in-lieu of elevation, provided all areas of the structure, together with attendant utility and sanitary facilities, below the regulatory flood protection elevation are made watertight with walls substantially impermeable to the passage of water, using structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. (c) For AO Zones, the floodproofing elevation shall be in accordance with Section 6.4.4 F, Standards for Areas of Shallow Flooding (Zone AO). A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the Engineering Services Director as set forth in Section 6.4.2 B, Certification Requirements, along with the operational and maintenance plans. 2. Manufactured Dwellings (a) New and replacement manufactured dwellings shall be elevated so that the reference level of the manufactured home is no lower than the regulatory flood protection elevation, as established in this section. (b) Manufactured homes shall be securely anchored to an adequately anchored foundation to resist flotation, collapse, and lateral movement, either by a certified engineered foundation system, or in accordance with the most current edition of the State of North Carolina Regulations for Manufactured Homes adopted by the Commissioner of Insurance pursuant to NCGS 143-143.15. (c) When the elevation would be met by an elevation of the chassis 36 inches or less above the grade at the site, the chassis shall be supported by reinforced piers or engineered foundation. When the elevation of the chassis is above 36 inches in height, an engineering certification is required. (d) All enclosures or skirting below the lowest floor shall meet the requirement of Section 6.4.3 B.3, Elevated Buildings. (e) An evacuation plan shall be developed for evacuation of residents of all new, substantially improved or substantially damaged manufactured home parks or subdivisions located within flood prone areas. This plan shall be filed with and approved by the Engineering Service Director and the local Emergency Management Coordinator. 3. Elevated Buildings Fully enclosed areas associated with new construction and substantially improved structures that are below the lowest floor shall comply with the following: (a) Not be designed or used for human habitation, but only be used for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises. Access to the enclosed area shall be the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment (standard exterior door), or entry to the living area (stairway or elevator). The interior portion of such enclosed area shall not be finished or partitioned into separate rooms, except to enclose storage areas. (b) Be constructed entirely of flood resistant materials at least to the regulatory flood protection elevation. (c) Include, in Zones A, AO, AE, and A1-30, flood openings to automatically equalize hydrostatic flood forces on walls by allowing for the entry and exit of floodwaters. To meet this requirement, the openings shall be certified by a professional engineer or architect or meet or exceed the following minimum design criteria: (1) A minimum of 2 flood openings on different sides of each enclosed area subject to flooding; (2) The total net area of all flood openings shall be at least 1 square inch for each square foot of enclosed area subject to flooding; (3) If a building has more than 1 enclosed area, each enclosed area shall have flood openings to allow floodwaters to automatically enter and exit; (4) The bottom of all required flood openings shall be no higher than 1 foot above the adjacent grade; (5) Flood openings may be equipped with screens, louvers, or other coverings or devices, provided they permit the automatic flow of floodwaters in both directions; and (6) Enclosures made of flexible skirting are not considered enclosures for regulatory purposes, and, therefore, do not require flood openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires flood openings as outlined above. 4. Additions/Improvements (a) Not a Substantial Improvement (1) In cases where an addition or improvement to a pre-FIRM structure does not constitute a substantial improvement, the addition or improvement shall be designed to minimize flood damages and shall not render the pre-FIRM structure any more nonconforming with respect to the standards in this section. (2) In cases where an addition and/or improvement to a post-FIRM structure does not constitute a substantial improvement to the existing structure, then only the additions or improvements shall comply with the standards for new construction. (3) Additions to post-FIRM structures with no modifications to the existing structure other than a standard door in a common wall shall require only the addition to comply with the standards for new construction. (b) Substantial Improvements In cases where an addition or improvement to a pre- or post-FIRM structure (whether in combination with interior modifications or not) do constitute a substantial improvement, both the existing structure and the addition and/or improvements shall comply with the standards for new construction. 5. Recreational Vehicles Recreational vehicles shall either: (a) Be on site for fewer than 180 consecutive days and be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities, and has no permanently attached additions); or (b) Meet all the requirements for new construction. 6. Temporary Non-Residential Structures Temporary nonresidential structures shall not remain within the special flood hazard area for a time period exceeding 3 months. This time period may be renewed up to a maximum of 1 year. 7. Accessory Structures (a) An accessory structure shall comply with the following: (1) Not be used for human habitation (including working, sleeping, living, cooking or restroom areas); (2) Not be temperature-controlled; (3) Be designed to have low flood damage potential; (4) Be constructed and placed on the building site so as to offer the minimum resistance to the flow of floodwaters; (5) Be firmly anchored; and (6) Incorporate flood openings to facilitate automatic equalization of hydrostatic flood forces below regulatory flood protection elevation, if necessary. (b) An accessory structure with a footprint less than 150 square feet that satisfies the criteria outlined above does not require an elevation or floodproofing certificate. (c) Elevation or floodproofing certifications are required for all other accessory structures in accordance with Section 6.4.2 B, Certification Requirements. C. Standards for Floodplains without Established Base Flood Elevations In addition to the standards in Section 6.4.3 A, General Standards, and Section 6.4.3 B, Specific Standards, development within the special flood hazard areas designated as Approximate Zone A and established in Section 6.4.1 B, Basis for Establishing Special Flood Hazard Areas, where no BFE is provided by FEMA, shall be subject to the following: 1. No encroachments, including fill, new construction, substantial improvements or new development shall be allowed within a distance of 20 feet each side from top of bank or 5 times the width of the stream, whichever is greater, unless certification with supporting technical data by a registered professional engineer is provided demonstrating that such encroachments will not result in any increase in flood levels during the occurrence of the base flood discharge; and 2. The BFE used in determining the regulatory flood protection elevation shall be determined based on the following criteria: (a) When BFE data is available from other sources, all new construction and substantial improvements within such areas shall also comply with all applicable provisions of this section and the Ordinance and shall be elevated or floodproofed. (b) All subdivision, manufactured home park, and other development proposals shall provide BFE data if development is greater than 5 acres or has more than 50 lots/manufactured home sites. The BFE data shall be adopted by reference in accordance with Section 6.4.1 B, Basis for Establishing Special Flood Hazard Areas, and utilized in implementing this section. (c) When BFE data is not available from a Federal, State, or other source as outlined above, the reference level shall be elevated to or above the regulatory flood protection elevation. D. Standards for Riverine Floodplains with BFE, but Without Established Floodways or Non-Encroachment Areas In addition to the standards in Section 6.4.3 A, General Standards, and Section 6.4.3 B, Specific Standards, development along rivers and streams where BFE data is provided by FEMA or is available from another source but neither floodway nor non-encroachment areas are identified for a special flood hazard area on the FIRM or in the FIS report, shall be subject to the following: 1. Until a regulatory floodway or non-encroachment area is designated, no encroachments, including fill, new construction, substantial improvements, or other development, shall be permitted unless certification with supporting technical data by a registered professional engineer is provided demonstrating that the cumulative effect of the proposed development, when combined with all other existing and anticipated development, will not increase the water surface elevation of the base flood more than 1 foot at any point within the community. E. Floodways and Non-Encroachment Areas In addition to the standards in Section 6.4.3 A, General Standards, and Section 6.4.3 B, Specific Standards, development proposed in floodways or non-encroachment areas established by Section 6.4.1 B, Basis for Establishing Special Flood Hazard Areas, shall be subject to the following: 1. No encroachments, including fill, new construction, substantial improvements and other developments shall be permitted unless: (a) It is demonstrated that the proposed encroachment would not result in any increase in the flood levels during the occurrence of the base flood, based on hydrologic and hydraulic analyses performed in accordance with standard engineering practice and presented to the Engineering Services Director prior to issuance of floodplain development permit; or (b) A conditional letter of map revision (CLOMR) is approved by FEMA. (c) A letter of map revision (LOMR) must also be obtained upon completion of the proposed encroachment. 2. If (E.1) above is satisfied, development shall comply with all applicable flood hazard reduction provisions of this section. 3. No manufactured dwellings shall be permitted, except replacement manufactured dwellings in an existing manufactured dwelling park or subdivision, provided the following provisions are met: (a) The anchoring and the elevation standards of Section 6.4.3 B.2, Manufactured Dwellings; and (b) The no encroachment standard of (1) above. F. Standards for Areas of Shallow Flooding (Zone AO) In addition to the standards in Section 6.4.3 A, General Standards, and Section 6.4.3 B, Specific Standards, development located within the Special Flood Hazard Areas established in Section 6.4.1 B, Basis for Establishing Special Flood Hazard Areas, as shallow flooding areas shall comply with the following: 1. The reference level shall be elevated at least as high as the depth number specified on the Flood Insurance Rate Map (FIRM), in feet, plus a freeboard of 2 feet, above the highest adjacent grade; or at least 2 feet above the highest adjacent grade if no depth number is specified; 2. Nonresidential structures may, in-lieu of elevation, be floodproofed to the same level as required by subsection F.1 above so that the structure, together with attendant utility and sanitary facilities below that level shall be watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. 3. Certification is required in accordance with Section 6.4.2 B, Certification Requirements; and 4. Adequate drainage paths shall be provided around structures on slopes, to guide floodwaters around and away from proposed structures.
Ask a question about High Point law
Corpus searches the High Point sections it holds and shows the ones that match, with their citations. Free, no sign-in.