§ 18-660 — Standards for areas where base flood elevation data has been provided

Code of Ordinances of the City of Wilmington, North Carolina (Supp. No. 43, Update 1: codified through Ordinance No. O-2026-51, enacted October 20, 2026) · Wilmington Code of Ordinances § 18-660

Corpus is an independent public-information project, not the official City of Wilmington website. Stable reference: corpuslaw.us/code/ebcf818d-e5a9-4be9-a3be-f582f21a43b9

Sec. 18-660. - Standards for areas where base flood elevation data has been provided.

In addition to the requirements of section 18-659, the following standards shall apply in all special flood hazard areas where base flood data has been provided by FEMA or as set forth in subsection 18-646(c): (a) Residential construction. All new construction or substantial improvement of any residential structure (including manufactured homes) shall have the lowest floor, including basement, elevated to at least two (2) feet above base flood elevation. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided. (b) Nonresidential construction. New construction or substantial improvement of any commercial, industrial, or nonresidential structure shall have the lowest floor, including basement, elevated at least two (2) feet above the base flood elevation. Structures located in "A" zones may be flood proofed in lieu of elevation provided that all areas of the structure below the required elevation are watertight with walls substantially impermeable to the passage of water, using structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the standards of this subsection are satisfied. Such certification shall be provided to the official as set forth in subsection 18-646(b). (c) Elevated buildings. (1) All new construction or substantial improvement of any elevated building that contains a fully enclosed area which is below the base flood elevation and which is formed by the foundation and other exterior walls shall: a. Not contain any finished living space and shall not be temperature controlled or conditioned with equipment below the regulatory flood protection elevation, but shall only be used for parking of vehicles, building access, or limited storage of maintenance equipment used in connection with the premises; b. Be constructed entirely of flood resistant materials below the regulatory flood protection elevation; c. Be designed to allow for the entry and exit of flood waters to automatically equalize hydrostatic flood forces on exterior walls. Designs for complying with this requirement must be certified by a registered professional engineer or licensed architect or must meet the following criteria: i. At least two (2) openings having a total net area of not less than one (1) square inch for every square foot of enclosed area subject to flooding must be provided; ii. The bottom of all openings shall be no higher than one (1) foot above grade; iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of flood waters in both directions; iv. If a building has more than one (1) enclosed area, each area must have openings to allow floodwaters to automatically enter and exit; and v. Foundation enclosures made of flexible skirting are not considered enclosures for regulatory purposes and, therefore, do not require openings. Masonry or wood underpinning, regardless of structural status, is considered an enclosure and requires openings. (2) Electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities shall be designed and located so as to prevent water from entering or accumulating within the components during flooding. (3) Access to the enclosed area shall be the minimum amount necessary to allow for parking of vehicles, such as a garage door, or limited storage of maintenance equipment used in connection with the premises, such as a standard exterior door, or entry to the living area, such as a stairway or elevator. (4) Except for enclosed storage areas, the interior portion of such enclosed areas shall not be partitioned or finished into separate rooms. (5) Areas below the regulatory flood protection elevation in Coastal High Hazard Areas (Zone VE and Coastal A Zones (CAZ)) shall either be free of obstruction or constructed with breakaway walls, latticework or insect screening. This is provided they are not part of the structural support of the building and are designed so as to breakaway, under abnormally high tides or wave action, without causing damage to the structural integrity of the building on which they are to be used, and provided the following design specifications are met: a. Material shall consist of open wood, plastic, or other latticework or insect screening having an opening ratio of at least forty (40) percent; and b. Breakaway walls shall meet the following design specifications: i. Design safe loading resistance of each wall shall be not less than ten (10) nor more than twenty (20) pounds per square foot; or ii. Breakaway walls that exceed a design safe loading resistance of more than twenty (20) pounds per square foot (either by design or when so required by State or local codes) shall be certified by a registered professional engineer or architect that the designed wall will collapse from a water load less than that which would occur during the base flood event, and the elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (structural and non-structural). The water loading values used shall be those associated with the base flood. The wind loading values used shall be those required by the North Carolina State Building Code. iii. Breakaway walls may have flood openings that allow for the automatic entry and exit of floodwaters to minimize damage caused by hydrostatic loads. (d) Manufactured homes. New and replacement manufactured homes shall be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated at least two (2) feet above the base flood elevation and must be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement: (1) All enclosures or skirting below the lowest floor shall meet the requirements contained herein. (2) Manufactured homes shall be securely anchored to prevent flotation, collapse, or lateral movement. For the purpose of this requirement, manufactured homes must be anchored to resist flotation, collapse, or lateral movement in accordance with the regulations for mobile homes and modular housing adopted by the commissioner of insurance pursuant to G.S. 143-143.15. Additionally, when the elevation would be met by an elevation of the chassis at least thirty-six (36) inches or less above the grade at the sight, the chassis shall be supported by reinforced piers or other foundation elements of at least equivalent strength. When the elevation of the chassis is above thirty-six (36) inches in height, an engineering certification is required. (3) An evacuation plan must be developed for evacuation of all residents of all new, substantially improved or substantially damaged manufactured home parks or subdivisions located within flood-prone areas. This plan shall be filed with and approved by the local administrator and the local emergency management coordinator. (e) Recreational vehicles. A recreational vehicle is ready for highway use if it is on wheels or jacking system, is attached to the site only by quick-disconnect-type utilities and security devices, and has no permanently attached additions. Recreation vehicles placed on sites shall adhere to one (1) of the following: (1) Be on the site for fewer than one hundred eighty (180) consecutive days; (2) Be fully licensed and ready for highway use (A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities, and has no permanently attached additions); or (3) Meet the requirements of section 18-646 and subsections 18-659(a), (d). (f) Temporary nonresidential structures. Prior to the issuance of a floodplain development permit for a temporary structure, the following requirements must be met: (1) All applicants must submit to the local administration prior to the issuance of the development permit a plan for the removal of such structure(s) in the event of a hurricane or flash flood warning notification. The plan must include the following information: a. A specified time period for which the temporary use will be permitted not to exceed one (1) year; b. The name, address and phone number of the individual responsible for the removal of the temporary structure; c. The time frame prior to the event at which a structure will be removed (i.e., minimum of seventy-two (72) hours before landfall of a hurricane or immediately upon flood warning notification); d. A copy of the contract or other suitable instrument with a trucking company to ensure the availability of removal equipment when needed; and e. Designation, accompanied by documentation, of a location outside the special flood hazard area to which the temporary structure will be moved. (2) The above information shall be submitted in writing to the local administrator for review and written approval. (g) Accessory structure. When accessory structures (sheds, detached garages, etc.) are to be placed in the floodplain, the following criteria shall be met: (1) Accessory structures shall be designed to have low flood damage potential. (2) Accessory structures shall be constructed and placed on the building site so as to offer the minimum resistance to the flow of flood waters. (3) Accessory structures shall be firmly anchored in accordance with subsection 18-659(a)(1)a. (4) Service facilities such as electrical shall be elevated in accordance with subsection 18-659(a)(5). Accessory structures shall not be temperature-controlled unless in compliance with requirements for principal structures. (5) Openings to facilitate automatic equalization of hydrostatic pressure during a flood shall be provided below base flood elevation in conformance with subsection 18-660(c)(1). (6) Accessory structures shall not be used for human habitation (including working, sleeping, living, cooking, or restroom areas). (7) An accessory structure with a footprint of less than one hundred fifty (150) square feet and that is does not exceed a cost of three thousand dollars ($3,000.00) and satisfies the criteria above is not required to meet the elevation or floodproofing standards of this section. Elevation or floodproofing certifications are required for all other accessory structures. (h) Tanks. When gas and liquid storage tanks are to be placed within a special flood hazard area, the following criteria shall be met: (1) Underground tanks. Underground tanks in flood hazard areas shall be anchored to prevent flotation, collapse, or lateral movement resulting from hydrodynamic and hydrostatic loads during conditions of the design flood, including the effects of buoyancy assuming the tank is empty; (2) Above-ground tanks, elevated. Above-ground tanks in flood hazard areas shall be elevated to or above the regulatory flood protection elevation on a supporting structure that is designed to prevent flotation, collapse, or lateral movement during conditions of the design flood. Tank-supporting structures shall meet the foundation requirements of the applicable flood hazard area; (3) Above-ground tanks, not elevated. Above-ground tanks that do not meet the elevation requirements of this ordinance shall be permitted in flood hazard areas provided the tanks are designed, constructed, installed, and anchored to resist all flood-related and other loads, including the effects of buoyancy, during conditions of the design flood and without release of contents into the floodwaters or infiltration by floodwaters into the tanks. Tanks shall be designed, constructed, installed, and anchored to resist the potential buoyant and other flood forces acting on an empty tank during design flood construction. (4) Tank inlets and vents. Tank inlets, fill openings, outlets, and vents shall be: 1) at or above the regulator flood protection elevation or fitted with covers designed to prevent the inflow of floodwater or outflow of the contents of the tanks during conditions of the design flood; and 2) anchored to prevent lateral movement resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy, during conditions of the design flood. (i) Concrete pads, including patios, decks, parking pads, walkways, driveways, pool decks, etc., shall: (1) Be structurally independent of the primary structural foundation system of the structure and shall not adversely affect structures through redirection of floodwaters or debris; and (2) Be constructed to breakaway cleanly during the design flood conditions, shall be frangible, and shall not produce debris capable of causing damage to any structure. The installation of concrete in small segments (not more than four (4) feet by four (4) feet) that will easily break up during the base flood event, or concrete that is scored in four-foot by four-foot segments, is acceptable to meet this standard; and (3) Not utilize welded wire fabric, rebar, or other similar reinforcement material; and (4) Not have a pad thickness greater than four (4) inches; and (5) Be certified by a design professional that the design and method of construction to be used meet the applicable criteria of this section. (6) The standards of this section shall not apply to nonresidential or multi-family development. (j) Swimming pools and spas must be designed to withstand all flood-related loads and load combinations and be either elevated so that the lowest horizontal structure is above the regulatory flood protection elevation; or designed and constructed to break away during base flood conditions without producing debris capable of causing damage to any structure; or be sited to remain in the ground during the base flood without obstructing flow that results in damage to any structure. A registered design professional must certify to local officials that a pool or spa beneath or near a VE zone building will not be subject to flotation or displacement that will damage building foundations or elevated portions of the building or any nearby buildings during a coastal flood. Pool equipment shall be floodproofed or elevated above the regulatory flood level and shall not be located beneath an elevated structure. (k) Elevators, vertical platform lifts, chair lifts, etc., shall comply with the following: (1) Elevator enclosures must be designed to resist hydrodynamic and hydrostatic forces as well as erosion, scour, and waves. (2) Utility equipment in coastal high hazard zones (VE and CAZ zones) must not be mounted on, pass through, or be located along breakaway walls. (3) The cab, machine/equipment room, hydraulic pump, hydraulic reservoir, counter weight and roller guides, hoist cable, limit switches, electric hoist motor, electrical junction box, circuit panel, and electrical control panel are required to be above the regulatory flood protection elevation or constructed using flood damage resistant components. (4) Elevator shafts/enclosures that extend below the regulatory flood protection elevation shall be constructed of reinforced masonry block or reinforced concrete walls to provide increased protection from flood damage. Drainage must be provided for the elevator pit. (5) If an elevator is designed to provide access to or from areas below the regulatory flood protection elevation, it shall be equipped with a float switch system that will activate during a flood and send the elevator cab to a flood above the regulatory flood protection elevation. (l) Fill/grading: Minor grading and the placement of minor quantities of nonstructural fill may be permitted for landscaping and for drainage purposes under and around buildings and for support of parking slabs, pool decks, patios, and walkways, provided: (1) The fill material must be similar and consistent with the natural soils in the area; and (2) The placement of site-compatible, non-structural fill under or around an elevated building is limited to two (2) feet; and (3) Nonstructural fill with finished slopes that are steeper than five (5) units horizontal to one (1) unit vertical shall be prohibited. (m) Other development: Fences, in the regulated floodways and nonencroachment areas (NEAs) that have the potential to block the passage of floodwaters, such as stockade fences and wire mesh fences; retaining walls, sidewalks, and driveways in the regulated floodways and NEAs the involve the placement of fill in regulatory floodways; and roads and watercourse crossings in regulated floodways and NEAs, including, bridges, culverts, low-water crossings, and similar means for vehicles or pedestrians to travel from one side of a watercourse to the other side, that encroach into regulated floodways and shall meet the limitations of Section 18-662.

(Ord. No. O-2006-26, §§ 1(d)—(f), 3-7-06; Ord. No. O-2018-46, §§ 31—38, 7-17-18)