Sec. 18-666. - Coastal high hazard areas (VE Zones and Coastal A zones (CAZ)) LiMWA.

Coastal High Hazard Areas are Special Flood Hazard Areas established in section 18-645, and designated as Zones VE or CAZ (LiMWA). These areas have special flood hazards associated with high velocity waters from surges and, therefore, in addition to meeting all other provisions in this ordinance with the exception of floodway and non-encroachment area provisions, the following provisions shall apply. (a) All development shall be located landward of the reach of mean high tide; be located landward of the first line of stable natural vegetation; and comply with all applicable CAMA setback requirements. (b) All new and substantially improved structures shall be elevated so that the bottom of the lowest horizontal structural member of the lowest floor (excluding pilings or columns) is located no lower than the regulatory flood protection elevation. Floodproofing shall not be utilized on any structures in coastal high hazard areas to satisfy the regulatory flood protection elevation requirements. (c) All space below the regulatory flood protection elevation shall be open so as not to impede the flow of water with the following exceptions: (1) Open latticework or insect screening may be permitted below the regulatory flood protection elevation for aesthetic purposes only and must be designed to wash away in the event of abnormal wave action and in accordance with section 18-660 of this article. Design plans shall be submitted in accordance with section 18-646 of this article; or (2) Breakaway walls may be permitted below the regulatory flood protection elevation provided they meet the criteria set forth in section 18-660 of this article. Breakaway walls used in CAZs may have flood openings that allow for the automatic entry and exit of floodwaters to minimize damage caused by hydrostatic loads. Design plans shall be submitted in accordance with section 18-646 of this article; (d) All new and substantially improved structures shall be securely anchored on pilings or columns. All pilings and columns and the structures attached thereto shall be anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading values used shall be those associated with the base flood. Wind loading values used shall be those required by the current edition of the North Carolina State Building Code. (e) A registered professional engineer or architect shall certify that the design, specifications and plans for construction are in compliance with the provisions contained in section 18-646, subsections 18-666(c), (d) and (f) of this article with the most current version of North Carolina's "National Flood Insurance Program V-Zone Certification" form. In addition, prior to the certificate of compliance/occupancy issuance, a registered professional engineer or architect shall certify the finished construction is compliant with the design, specifications, and plans for VE zone construction. (f) Fill shall not be used for structural support. Up to two (2) feet of non-compacted and non-stabilized fill may be used around the perimeter of a building for landscaping and aesthetic purposes provided the fill will wash out from storm surge, thereby rendering the building free of obstruction prior to generating excessive loading forces, ramping effects, or wave deflection. Design plans shall be submitted in accordance with section 18-646 of this article. The floodplain administrator may approve design plans for landscaping/aesthetic fill only after the applicant has provided an analysis by an engineer, architect, and/or soil scientist which demonstrates that the following factors have been satisfied: (1) Particle composition of fill material does not have a tendency for excessive natural compaction; (2) Volume and distribution of fill will not cause wave deflection to adjacent properties; and (3) Slope of fill will not cause wave run-up or ramping. (g) There shall be no alteration of sand dunes which would increase potential flood damage. (h) No manufactured homes shall be permitted except in an existing manufactured housing park. A replacement manufactured home may be placed on a lot in an existing manufactured housing park provided the anchoring and elevation standards are in compliance with this section of ordinance. (i) Recreational vehicles may be permitted in coastal high hazard areas provided that they meet the recreational vehicle criteria of subsection 18-660(e) of this article and the temporary structure provisions of subsection 18-660(f) of this article. (j) A deck that is structurally attached to a building or structure shall have the bottom of the lowest horizontal structural member at or above the regulatory flood protection elevation and any supporting members that extend below the regulatory flood protection elevation shall comply with the foundation requirements that apply to the building or structure, which shall be designed to accommodate any increased loads resulting from the attached deck. The increased loads must be considered in the design of the primary structure and included in the required V-Zone certification. (k) A deck or patio that is located below the regulatory flood protection elevation shall be structurally independent from buildings or structures and their foundation systems, and shall be designed and constructed either to remain intact and in place during design flood conditions or to break apart into small pieces to minimize debris during flooding that is capable of causing structural damage to the building or structure or to adjacent buildings or structures. (l) In coastal high hazard areas, development activities other than buildings and structures shall be permitted only if also authorized by the appropriate state or local authority; if located outside the footprint of, and not structurally attached to, buildings and structures; and if analyses prepared by qualified registered design professionals demonstrate no harmful diversion of floodwaters or wave runup and wave reflection that would increase damage to adjacent buildings and structures. Such other development activities include but are not limited to: 1) bulkheads, seawalls, retaining walls, revetments, and similar erosion control structures; and 2) fences, unless designed and constructed to fail under flood conditions less than the design flood or otherwise function to avoid obstruction of floodwaters.

(Ord. No. O-2006-26, § 2, 3-7-06; Ord. No. O-2018-46, §§ 43, 44, 7-17-18)

Ask a question about Wilmington law

Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.