For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.03.125 — Section 202 Amended; Definitions

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 19.03.125

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/bcdd7085-b18c-45f0-824f-133aa26611be

19.03.125 Section 202 Amended; Definitions.

Section 202 of the International Fire Code is amended to add/amend the following definitions: FIREWORKS, 1.3G. Large fireworks devices, which are explosive materials, intended for use in fireworks displays and designed to produce audible or visible effects by combustion, deflagration or detonation. Such 1.3G fireworks include, but are not limited to, firecrackers containing more than 130 milligrams (2 grains) of explosive composition, aerial shells containing more than 40 grams of pyrotechnic composition and other display pieces which exceed the limits for classification as 1.4G fireworks. Such 1.3G fireworks are also described as Fireworks, UN 0335 by the DOTn. Such 1.3G fireworks may also be known as display fireworks or Class B fireworks. FIREWORKS, 1.4G. Small fireworks devices containing restricted amounts of pyrotechnic composition designed primarily to produce visible or audible effects by combustion or deflagration that complies with the construction, chemical composition and labeling regulations of the DOTn for Fireworks, UN 0336, and the U.S. Consumer Product Safety Commission as set forth in CPSC 16 CFR Parts 1500 and 1507. Such 1.4G fireworks may also be known as consumer fireworks or Class C fireworks. FIREWORKS RETAILER. Any person engaged in the business of making sales of fireworks at retail to consumers. FIRE SUPPRESSION SYSTEMS. An all-inclusive term to capture the three (3) different types of fire suppression systems. The term fire suppression systems shall be subcategorized under one the following systems: Sprinkler System. Including, but not limited to, auto­matic sprinkler systems, standpipe systems, foam-extinguishing systems, or automatic water mist systems used to extinguish or control a fire. Wet/Dry Chemical System. Including, but not limited to, wet chemical extinguishing systems or dry chemical extinguishing systems used to extinguish or con­trol a fire. Gas Extinguishing System. Including, but not limited to, carbon dioxide extinguishing systems, halogenated extinguishing systems, clean-agent fire-extinguishing systems, or aerosol fire-extinguishing systems used to extinguish or control a fire. FIRE SUPPRESSION SYSTEM APPRENTICE. A person, other than a fire suppression system contractor or journeyman, who is engaged in learning and assisting in the install­ation, alteration, repair, inspection, and testing of a fire suppression system as an employee under the direct supervision and in the immediate presence of a fire suppression system contractor or journey­man. The term fire suppression system apprentice shall be subcategorized under one the following: Sprinkler System Apprentice. See Fire Suppression Systems; Sprinkler System definition to determine the scope of work limited to a sprinkler system apprentice. Wet/Dry Chemical System Apprentice. See Fire Suppression Systems; Wet/Dry Chemical System definition to determine the scope of work limited to a wet/dry chemical system apprentice. Gas Extinguishing System Apprentice. See Fire Suppression Systems; Gas Extinguishing System definition to determine the scope of work limited to a gas extinguishing system apprentice. FIRE SUPPRESSION SYSTEM CONTRACTOR. Any person who holds themselves out as skilled in designing, planning, and supervising in the installation, alteration, modification, repair, inspection, and testing of a fire suppression system and who can meet all the required qualifications established by this code. The fire suppression system contractor shall be engaged in contracting for such work with full responsi­bility of supervision, whether doing such work themselves or employing fire suppression system journeymen or appren­tice for assistance. The term fire suppression system contractor shall be subcategorized under one the following: Sprinkler System Contractor. See Fire Suppression Systems; Sprinkler System definition to determine the scope of work limited to a sprinkler system contractor. Wet/Dry Chemical System Contractor. See Fire Suppression Systems; Wet/Dry Chemical System definition to determine the scope of work limited to a wet/dry chemical system contractor. Gas Extinguishing System Contractor. See Fire Suppression Systems; Gas Extinguishing System definition to determine the scope of work limited to a gas extinguishing system contractor. FIRE SUPPRESSION SYSTEM JOURNEYMAN. Any person employed by a fire suppression system contractor, other than a fire suppression system appren­tice, who is engaged in the install­ation, alteration, repair, inspection, and testing of a fire suppression system, and the supervision thereof, and who can meet all the required qualifications established by this code. The term fire suppression system journeyman shall be subcategorized under one the following: Sprinkler System Journeyman. See Fire Suppression Systems; Sprinkler System definition to determine the scope of work limited to a sprinkler system journeyman. Wet/Dry Chemical System Journeyman. See Fire Suppression Systems; Wet/Dry Chemical System definition to determine the scope of work limited to a wet/dry chemical system journeyman. Gas Extinguishing System Journeyman. See Fire Suppression Systems; Gas Extinguishing System definition to determine the scope of work limited to a gas extinguishing system journeyman. JURISDICTION. Whenever the word jurisdiction is used in the International Fire Code (IFC), it shall be held to mean the jurisdiction of the City of Lincoln, Nebraska. OCCUPANCY CLASSIFICATION; Residential Group R-3. Residential Group R-3 occupancies where the occupants are primarily permanent in nature and not classified as Group R-1, R-2, R-4 or I, including: Buildings that do not contain more than two dwelling units. Care facilities that provide accommodations for five or fewer persons receiving custodial care. Care facilities that provide accommodations for twelve or fewer persons receiving personal care. Congregate living facilities (nontransient) with 16 or fewer occupants: Boarding houses (nontransient); Convents; Dormitories; Fraternities and sororities; Monasteries. Congregate living facilities (transient) with 10 or fewer occupants: Boarding houses (transient). Lodging houses (transient) with five or fewer guestrooms and 10 or fewer occupants. OCCUPANCY CLASSIFICATION; Residential Group R-3; Care facilities within a dwelling. Care facilities for five or fewer persons receiving care that are within a single-family dwelling are permitted to comply with the International Residential Code. OCCUPANCY CLASSIFICATION; Institutional Group I4, Daycare Facilities; Child Daycare Facilities for Twelve or Fewer Occupants in a Dwelling Unit. A child daycare facility located within a dwelling unit and having twelve or fewer persons receiving custodial care shall be classified as a Group R-3 Occupancy or shall comply with the International Residential Code. PUBLIC WAY. A street, alley or other parcel of land open to the outside air leading to a street, that has been deeded, dedicated or otherwise permanently appropriated to the public for public use and which has a clear width and height of not less than 10 feet (3048 mm). For the purposes of fire separation and area calculations, active primary railroad lines where railcars cannot be parked for extended periods of time may also be considered as a public way. (: Ord. 20259 §3; October 19, 2015).

(Ord. 21821 §33; December 15, 2025; Ord. 21116 §26; August 23, 2021)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.