20.12.155 Table R301.7 Amended; Allowable Deflection of Structural Members.

Table R301.7 of the International Residential Code is amended to read as follows: TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS STRUCTURAL MEMBER | ALLOWABLE DEFLECTION Rafters having slopes greater than 3/12 With finished ceiling not attached to rafters | L/180 Interior walls and partitions | H/240 Floors – 16’-6” span or less | L/360 Floors – over 16’-6” span | L/480 Ceilings with brittle finishes (including plaster and stucco) | L/360 Ceilings with flexible finishes (including gypsum board) | L/240 All other structural members | L/240 Exterior walls – wind loads a with plaster or stucco finish | H/360 Exterior walls – wind loads a with other brittle finishes | H/240 Exterior walls – wind loads a with flexible finishes | H/180d Lintels supporting masonry veneer walls e | L/600 Note: L = span length, H = span height Footnotes a-e to Table No. R301.7 of this code shall apply. ().

(Ord. 21820 §7; December 15, 2025; Ord. 20937 §30; June 29, 2020)