§ 20.12.225 — Table R302.6 Amended; Dwelling/Garage Fire Separation
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 20.12.225
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/40544a77-6eae-4d62-bf45-fc3fa7d97ce2
20.12.225 Table R302.6 Amended; Dwelling/Garage Fire Separation.
Table R302.6 of the International Residential Code is amended to read as follows: TABLE R302.6 DWELLING/GARAGE SEPARATION SEPARATION | MATERIAL From the residence and attics | Not less than 5/8-inch type X gypsum board or equivalent applied to the garage side. Structure(s) supporting floor/ceiling assemblies used for separation required by this section | Not less than 5/8-inch type X gypsum board or equivalent. Garages located less than 6 feet from a dwelling unit on the same lot | Not less than 5/8 type X gypsum board or equivalent applied to the interior side of exterior walls that area within this area. ().
(Ord. 20937 §44; June 29, 2020)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.
