20.12.225 Table R302.6 Amended; Dwelling/Garage Fire Separation.

Table R302.6 of the International Residential Code is amended to read as follows: TABLE R302.6 DWELLING/GARAGE SEPARATION SEPARATION | MATERIAL From the residence and attics | Not less than 5/8-inch type X gypsum board or equivalent applied to the garage side. Structure(s) supporting floor/ceiling assemblies used for separation required by this section | Not less than 5/8-inch type X gypsum board or equivalent. Garages located less than 6 feet from a dwelling unit on the same lot | Not less than 5/8 type X gypsum board or equivalent applied to the interior side of exterior walls that area within this area. ().

(Ord. 20937 §44; June 29, 2020)