20.12.525 Section R404.1.5.2 Amended; Concrete Wall Thickness.

Section R404.1.5.2 of the International Residential Code is amended to read as follows: R404.1.5.2 Concrete wall thickness. The thickness of concrete foundation walls shall be equal to or greater than the thickness of the wall in the story above. Concrete foundation walls with corbels, brackets or other projections built into the wall for support of masonry veneer or other purposes are not within the scope of the tables in this section. Where a concrete foundation wall is reduced in thickness to provide a 4-inch shelf for the support of masonry veneer or a bearing ledge for joists, the reduced thickness of the wall shall not be less than 6 inches. Vertical reinforcement shall be based on the thickness of the thinner portion of the wall. Exception: Where the height of the reduced thickness portion measured to the underside of the floor assembly or sill plate above is less than or equal to 24 inches and the reduction in thickness does not exceed 4 inches, the vertical reinforcement is permitted to be based on the thicker portion of the wall. ().

(Ord. 20937 §104; June 29, 2020)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.