24.12.100 Section 105.0 Amended; Inspection and Testing.
Section 105.0 of the Uniform Plumbing Code is amended to read as follows: 105.0 Inspection and Testing. All rough and finish plumbing shall be tested with air or water as prescribed in this code. When it is necessary to cover a portion of the work before all of the rough plumbing is ready for inspection, Authority Having Jurisdiction must be notified and a test made by filling the same with water under a pressure that will be equal to the entire plumbing system when filled to the top of the highest vent pipe. If the groundwork is to be connected to the sewer, there shall be a suitable fitting left in the main soil pipe not more than one foot from where the soil pipe enters the building, so that a testing plug can be inserted. The Authority Having Jurisdiction, upon approving the rough plumbing or drainage work, shall place thereon a notice stating that the same has been inspected and approved. The system shall be tested with 5 PSI of air or 10’ water head test. (: Ord. 20525 §19, August 21, 2017).
(Ord. 21176 §15; December 13, 2021)