- § 24.12.005 — Adoption of 2021 Uniform Plumbing Code
- § 24.12.010 — Authority Having Jurisdiction; Designation
- § 24.12.015 — Section 101.0 Amended; Title, Purpose and Scope
- § 24.12.020 — Section 101.2 Amended; Scope
- § 24.12.025 — Section 101.3 Amended; Purpose
- § 24.12.030 — Section 102.2 Amended; Existing Installation
- § 24.12.050 — Reports and Records
- § 24.12.060 — Enforcement
- § 24.12.065 — Section 104.1 Amended; Permit Required
- § 24.12.070 — Section 104.2 Deleted; Exempt Work
- § 24.12.080 — Section 104.3 Amended; Application for Permit
- § 24.12.083 — Section 104.3.3 Deleted; Time Limitation Application
- § 24.12.085 — Section 104.4 Amended; Permit Issuance
- § 24.12.090 — Section 104.4.3 Deleted; Expiration
- § 24.12.095 — Section 104.5 Amended; Fees
- § 24.12.100 — Section 105.0 Amended; Inspection and Testing
- § 24.12.105 — Sections 105.3, 105.3.1, 105.3.2, 105.3.3 Deleted; Test, Test Waived, Exceptions, Tightness
- § 24.12.110 — Section 105.2.3 Amended; Inspection Requests
- § 24.12.115 — Plumbing Code Task Force
- § 24.12.120 — Examining Board of Plumbers
- § 24.12.125 — Registration of Plumbers
- § 24.12.130 — Certificate of Insurance
- § 24.12.135 — Sanitary Sewer Connection
- § 24.12.136 — Section 106.4 Amended; Stop Orders
- § 24.12.137 — Section 106.6 Amended; Authority to Condemn
- § 24.12.138 — Section 107.0 Amended; Board of Appeals
- § 24.12.140 — Section 212.0 Amended; Definitions - J
- § 24.12.145 — Section 218.0 Amended; Definitions - P
- § 24.12.150 — Section 220.0 Amended; Definitions - R
- § 24.12.155 — Section 221.0 Amended; Definitions – S
- § 24.12.157 — Section 223.0 Amended; Definitions - U
- § 24.12.160 — Section 224.0 Amended; Definitions - V
- § 24.12.165 — Section 310.1 Amended; Fittings
- § 24.12.170 — Section 310.3 Deleted; Waste Connection
- § 24.12.180 — Section 310.8 Amended; Screwed Fittings
- § 24.12.182 — Section 311.0 Amended; Independent Systems
- § 24.12.184 — Section 312.6 Amended; Freezing Protection
- § 24.12.186 — Section 314.4.1 Deleted; Installation of Thermoplastic Pipe and Fittings
- § 24.12.187 — Section 320.0 Deleted; Rehabilitation of Piping Systems
- § 24.12.191 — Section 407.3 Amended; Limitation of Hot Temperature for Public Lavatories
- § 24.12.196 — Section 407.4 Deleted; Transient Public Lavatories
- § 24.12.201 — Section 408.3 Amended; Individual Shower and Tub-Shower Combination Control Valves
- § 24.12.206 — Section 408.7.3 Amended; Sheet Lead
- § 24.12.211 — Section 409.4 Amended; Limitation of Hot Water in Bathtubs and Whirlpool Bathtubs
- § 24.12.214 — Section 412.1.1 Deleted; Nonwater Urinals
- § 24.12.215 — Section 412.1.2 Deleted; Nonwater Urinals with Drain Cleansing Action
- § 24.12.217 — Section 414.3 Amended; Drainage Connection
- § 24.12.218 — Section 418.3 Amended; Location of Floor Drains
- § 24.12.220 — Table 422.1 Amended; Minimum Plumbing Facilities
- § 24.12.222 — Section 422.2 Amended; Separate Facilities
- § 24.12.225 — Table 501.1(2) Amended; First Hour Rating
- § 24.12.227 — Section 507.2 Deleted; Seismic Provisions
- § 24.12.230 — Section 509.0 Deleted; Venting of Appliances
- § 24.12.235 — Section 510.0 Deleted; Sizing of Category I Venting Systems
- § 24.12.237 — Table 603.2 Amended; Backflow Prevention Devices, Assemblies, and Methods
- § 24.12.239 — Section 603.4.6.1 Added; Water Connection for Chemical Dispenser
- § 24.12.245 — Table 604.1 Amended; Materials for Building Supply and Water Distribution Piping and Fittings
- § 24.12.250 — Section 604.3 Amended; Copper Tube
- § 24.12.255 — Section 604.5 Deleted; Flexible Connectors
- § 24.12.265 — Section 604.12 Amended; Flexible Connectors
- § 24.12.270 — Section 604.13 Amended; Water Heater Connectors
- § 24.12.271 — Section 605.2 CPVC Plastic Pipe and Joints through Section 605.2.3 Threaded Joints; Amended
- § 24.12.272 — Sections 605.3 through 605.3.2.1 Deleted; CPVC/AL/CPVC Plastic Pipe and Joints
- § 24.12.275 — Section 605.12 Deleted; PVC Plastic Pipe and Joints
- § 24.12.280 — Section 606.5 Amended; Control Valve
- § 24.12.285 — Section 608.5 Amended; Discharge Piping
- § 24.12.290 — Section 609.3 Amended; Under Concrete Slab
- § 24.12.295 — Section 609.5 Deleted; Unions
- § 24.12.300 — Section 609.6 Deleted; Location
- § 24.12.310 — Section 609.11 Amended; Water Hammer
- § 24.12.312 — Sections 609.12 through 609.12.2 Deleted; Pipe Insulation
- § 24.12.315 — Table 610.3 Amended; Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes
- § 24.12.317 — Sections 612.0 through 612.7.2 Deleted; Residential Fire Sprinkler System
- § 24.12.320 — Section 701.2 Amended; Drainage Piping
- § 24.12.325 — Table 701.2 Amended; Materials for Drain, Waste, Vent Pipe and Fittings
- § 24.12.330 — Section 701.5 Amended; Lead
- § 24.12.333 — Section 703.1 Amended; Building Drain (Minimum Size)
- § 24.12.334 — Table 703.2 Amended; Maximum Unit Loading and Maximum Length of Drainage and Vent Piping
- § 24.12.336 — Section 705.1 ABS and ABS Co-Extruded Plastic Pipe and Joints
- § 24.12.344 — Section 710.1 Backflow Protection
- § 24.12.345 — Section 712.1 Amended; Media
- § 24.12.350 — Section 713.4 Amended; Public Sewer Availability
- § 24.12.355 — Section 804.1 Amended; Standpipe Receptors
- § 24.12.356 — Section 807.3 Amended; Domestic Dishwashing Machine
- § 24.12.365 — Section 810.2 Amended; Sumps, Condensers, and Intercepting Tanks
- § 24.12.370 — Section 901.2 Amended; Vents Required
- § 24.12.375 — Section 903.1 Amended; Applicable Standards
- § 24.12.380 — Section 903.2 Amended; Use of Copper or Copper Alloy Tubing
- § 24.12.385 — Section 904.1 Amended; Size
- § 24.12.390 — Section 905.7 Added; Two-inch Minimum Vent
- § 24.12.391 — Section 906.1 Amended; Roof Termination
- § 24.12.392 — Section 906.3 Amended; Use of Roof
- § 24.12.395 — Section 906.6 Amended; Lead
- § 24.12.400 — Section 906.7 Amended; Frost or Snow Closure
- § 24.12.405 — Section 908.3 Added; Horizontal Wet Venting for other than bathroom groups
- § 24.12.410 — Sections 909.0 and 909.1 Amended; Special Venting for Island Fixtures; General
- § 24.12.415 — Section 1001.2 Amended; Where Required
- § 24.12.417 — Section 1007.2 Amended; Trap Seal Primers
- § 24.12.420 — Section 1014.3.5 Amended; Construction Requirements
- § 24.12.425 — Section 1101.4 Amended; Material Uses
- § 24.12.426 — Section 1101.4.2 Amended; Inside of Conductors
- § 24.12.430 — Sections 1101.6 Amended; Subsoil Drains
- § 24.12.432 — Sections 1101.6.3 through 1101.11 Deleted; From Subsoil Drains
- § 24.12.445 — Section 1101.15 Deleted; Traps on Storm Drains and Leaders
- § 24.12.450 — Section 1101.16.2 Deleted; Combining Storm with Sanitary Drainage
- § 24.12.460 — Section 1102.3.1 Amended; Lead Flashing
- § 24.12.462 — Sections 1103.1 and 1103.2 Amended; Size of Leaders, Conductors and Storm Drains
- § 24.12.465 — Section 1103.3 Deleted; Size of Roof Gutters
- § 24.12.470 — Section 1103.4 Deleted; Side Walls Draining Onto a Roof
- § 24.12.475 — Chapters 12 and 14 Deleted; Fuel Gas Piping, Firestop Protection
- § 24.12.480 — General Provisions
- § 24.12.482 — Definitions
- § 24.12.484 — Permit Required; Fees
- § 24.12.485 — Inspection
- § 24.12.486 — Registration of Water Conditioning Contractors and Installers
- § 24.12.489 — Corporations; Business Entities
- § 24.12.490 — Application for Registration; Examination
- § 24.12.492 — Registration Expiration; Renewal; Examinations
- § 24.12.494 — Certificate of Insurance
- § 24.12.495 — Suspension or Revocation of Registration
- § 24.12.496 — Registration Use By Another Person; Violation; Penalties
- § 24.12.501 — Permit to Excavate
- § 24.12.502 — Excavations, Lights, and Barricades
- § 24.12.504 — Refilling Excavations
- § 24.12.506 — Restoration of Surface
- § 24.12.508 — Refilling Excavations; Private Property
- § 24.12.601 — General Provisions
- § 24.12.602 — Irrigation System Contractor; Definition
- § 24.12.603 — Permit Required
- § 24.12.604 — Application for Permit
- § 24.12.606 — Permit to Install Water Supply Piping from Water System
- § 24.12.608 — Permit to Install Irrigation System
- § 24.12.612 — Installation
- § 24.12.614 — Inspections
- § 24.12.615 — Certificate of Insurance
- § 24.12.617 — Violations and Penalties
- § 24.12.700 — Adoption of Chapter 12 of the 2012 Mechanical Code
- § 24.12.704 — Appendix D, Table D 1.1, Amended; Sizing Storm Water Drainage Systems, Maximum Rates of Rainfall for Various Cities
- § 24.12.705 — Appendix E 7 Amended; M/H Lot Drainage Inlet and Lateral
- § 24.12.710 — Appendix E 9 Amended; Pipe Size
- § 24.12.715 — Alternate Plumbing System Drawings; Appendix C 10.0