24.12.333 Section 703.1 Amended; Building Drain (Minimum Size).

Section 703.1 of the Uniform Plumbing Code is amended to read as follows: 703.1 Building Drain (Minimum Size). Building drains serving a single structure shall be a minimum of four (4) inches to the first three (3) inch or larger stack. EXCEPTION: Where the sewer comes in above the basement floor or where the house drain runs above the ground, in which case each four (4) inch sewer shall have one four (4) inch cleanout at the basement wall and may be reduced to three (3) inch at that point. (: Ord. 20525 §66, August 21, 2017).

(Ord. 21817 §34; December 15, 2025)