For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24.12.271 — Section 605.2 CPVC Plastic Pipe and Joints through Section 605.2.3 Threaded Joints; Amended

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.12.271

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/a423ed37-949b-4a51-94a7-6abed0e81855

24.12.271 Section 605.2 CPVC Plastic Pipe and Joints through Section 605.2.3 Threaded Joints; Amended.

Section 605.2 CPVC Plastic Pipe and Joints through Section 605.2.3 Threaded Joints of the Uniform Plumbing Code is amended to read as follows: 605.2 Corzan (IPS) Sch. 80 CPVC Plastic Pipe and Joints. Corzan (IPS) Sch. 80 CPVC plastic pipe and fitting joining methods shall be installed in accordance with the manufacturer’s installation instructions and shall comply with Section 605.2.1 through Section 605.2.3. 605.2.1 Mechanical Joints. Mechanical joints shall include compression, flanged, grooved and push fit fittings. 605.2.1.1 Push Fit Fittings. Removable and nonremovable push fit fittings that employ a quick assembly push fit connector shall comply with ASSE 1061. 605.2.2 Solvent Cement Joints. Solvent cement joints for Corzan (IPS) Sch. 80 CPVC pipe and fittings shall be clean from dirt and moisture. Solvent cements shall meet or exceed the requirements of ASTM F493, requiring the use of a primer that meets or exceed the requirements of ASTM F656. The primer shall be purple in color and shall comply with ASTM F656, as well as being approved for use in potable water systems. Apply primer where required inside the fitting and to the depth of the fitting on pipe. Apply liberal coat of cement to the outside surface of pipe to depth of fitting and inside of fitting. Place pipe inside fitting to forcefully bottom the pipe in the socket and hold together until joint is set. 605.2.3 Threaded Joints. Threading of Corzan (IPS) Sch. 80 CPVC pipe shall be prohibited. Threads on pre-molded fittings shall comply with ASME B1.20.1. The use of molded fittings shall not result in a 50 percent reduction in the pressure rating of the pipe provided that the molded fittings shall be fabricated so that the wall thickness of the material is maintained at the threads. Thread sealant compound that is compatible with the pipe and fitting, insoluble in water, and nontoxic shall be applied to male threads. Caution shall be used during assembly to prevent over tightening of the Corzan (IPS) Sch. 80 CPVC components once the thread sealant has been applied. Female Corzan (IPS) Sch. 80 CPVC threaded fittings shall be used with plastic male threads only. 605.2.4 Certifications. All installers of Corzan (IPS) Sch. 80 CPVC pipe and fittings shall be trained and certified in the installation of the material through a factory trained instructor. All certified individuals shall keep a valid copy of their certification to be presented upon request. ().

(Ord. 21817 §26; December 15, 2025)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.