For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24.12.320 — Section 701.2 Amended; Drainage Piping

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.12.320

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/6aa6e5f6-6030-4793-b42a-7c966ee17ce2

24.12.320 Section 701.2 Amended; Drainage Piping.

Section 701.2 of the Uniform Plumbing Code is amended to read as follows: 701.2 Drainage Piping. Materials for drainage piping shall be in accordance with one of the referenced standards in Table 701.2 except that: (1) 1. No galvanized wrought iron or galvanized steel pipe shall be used underground and shall be kept not less than 6 inches (152 mm) above ground. (2) 2. PVC DWV piping installations shall be installed in accordance with applicable standards referenced in Table 701.2 and Chapter 14 “Firestop Protection”. Except for individual single-family dwelling units, materials exposed within ducts or plenums shall have a flame-spread index of not more than 25 and a smoke-developed index of not more than 50, where tested in accordance with ASTM E84 or UL 723. Plastic piping installed in plenums shall be tested in accordance with all requirements of ASTM E84 or UL 723. Mounting methods, supports and sample sizes of materials for testing that are not specified in ASTM E84 or UL 723 shall be prohibited. (3) 3. No vitrified clay pipe or fittings shall be used above ground or where pressurized by a pump or ejector. They shall be kept not less than 12 inches (305 mm) below ground. (4) 4. Copper or copper alloy tube for drainage and vent piping shall have a weight of not less than that of copper or copper alloy drainage tube type DWV. EXCEPTION: Type L shall be required underground. (1) 5. Stainless steel 304 pipe and fittings shall not be installed under ground and shall be kept not less than 6 inches (152 mm) above ground. (2) 6. Cast-iron soil pipe and fittings and the stainless steel couplings used to join these products shall be listed and tested in accordance with standards referenced in Table 701.2. Such pipe and fittings shall be marked with the country of origin, manufacturer’s name or registered trademark as defined in the product standards, the third-party certifier’s mark, and the class of the pipe or fitting. (: Ord. 20525 §63; August 21, 2017).

(Ord. 21817 §33; December 15, 2025; Ord. 21176 §47; December 13, 2021)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.