§ 24.12.315 — Table 610.3 Amended; Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.12.315

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/62943fed-28d9-4a00-8de8-54bc3f01dd3c

24.12.315 Table 610.3 Amended; Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes.

Table 610.3 of the Uniform Plumbing Code is amended to read as follows: Table 610.3 Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes 1/2 inch = 15 mm 3/4 inch = 20 mm 1 inch = 25 mm Appliances, Appurtenances or Fixtures2 | Minimum Fixture Branch Pipe Size1,3 | Private | Public | Assembly5 Bathtub or Combination Bath/Shower (fill) | 1/2" | 4.0 | 4.0 | -- 3/4” Bathtub Fill Valve | 3/4” | 10 | 10 | -- Bidet | 1/2" | 1.0 | -- | -- Clothes washer | 1/2" | 4.0 | 4.0 | -- Dental Unit, cuspidor | 1/2" | -- | 1.0 | -- Dishwasher, domestic | 1/2" | 1.5 | 1.5 | -- Drinking Fountain or Water cooler | 1/2" | 0.5 | 0.5 | 0.75 Hose Bibb | 1/2" | 2.5 | 2.5 | -- Hose Bibb, each additional7 | 1/2" | 1.0 | 1.0 | -- Lavatory | 1/2" | 1.0 | 1.0 | 1.0 Mobile Home, each (minimum) | -- | 12.0 | -- | -- Sinks | -- | -- | -- | -- Bar | 1/2" | 1.0 | 2.0 | -- Clinic Faucet | 1/2” | -- | 3.0 | -- Clinic Flushometer Valve with or without faucet | 1” | -- | 8.0 | -- Kitchen, domestic | 1/2" | 1.5 | 1.5 | -- Laundry | 1/2" | 1.5 | 1.5 | -- Service or Mop Basin | 1/2" | 1.5 | 3.0 | -- Washup, each set of faucets | 1/2" | -- | 2.0 | -- Shower, per head | 1/2" | 2.0 | 2.0 | -- Urinal, 1.0 GPF Flushometer Valve | 3/4” | See Footnote 6 | -- Urinal, greater than 1.0 GPF Flushometer Valve | | See Footnote 6 | -- Urinal, flush tank | 1/2” | 2.0 | 2.0 | 3.0 Wash fountain, circular spray | 3/4” | -- | 4.0 | -- Water Closet, 1.6 GPF Gravity Tank | 1/2” | 2.5 | 2.5 | 3.5 Water Closet, 1.6 GPF Flushometer Tank | 1/2" | 2.5 | 2.5 | 3.5 Water Closet, 1.6 GPF Flushometer Valve | 1” | See Footnote 6 | -- Water Closet, greater than 1.6 GPF Gravity Tank | 1/2” | 3.0 | 5.5 | 7.0 Water Closet, greater than 1.6 GPF Flushometer Valve | 1” | See Footnote 6 | -- Notes: 1Size of the cold branch pipe, or both the hot and cold branch pipes. 2Appliances, Appurtenances or Fixtures not included in this Table may be sized by reference to fixtures having a similar flow rate frequency of use. 3The listed minimum supply branch pipe sizes for individual fixtures are the nominal (I.D.) pipe size. 4For fixtures or supply connections likely to impose continuous flow demands, determine the required flow in gallons per minute (GPM) and add it separately to the demand (in GPM) for the distribution system or portions thereof. 5Assembly [Public Use (See Table 422.1)]. 6When sizing flushometer systems see Section 610.10. 7Reduced fixture unit loading for additional hose bibbs as used is to be used only when sizing total building demand and for pipe sizing when more than one hose bibb is supplied by a segment of water distributing pipe. The fixture branch to each hose bibb shall be sized on the basis of 2.5 fixture units. (: Ord. 20525 §62, August 21, 2017).

(Ord. 21817 §31; December 15, 2025)