§ 24.12.245 — Table 604.1 Amended; Materials for Building Supply and Water Distribution Piping and Fittings
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.12.245
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/06b76f29-5add-4fcb-91ea-632cb28619d6
24.12.245 Table 604.1 Amended; Materials for Building Supply and Water Distribution Piping and Fittings.
Table 604.1 of the Uniform Plumbing Code is hereby amended to read as follows: [See Table 604.1 on Next Page] TABLE 604.1 Materials for Building Supply and Water Distribution Piping and Fittings Material | Building Supply Pipe and Fittings | Water Distribution Pipe and Fittings | Referenced Standard(s) Pipe | Referenced Standard(s) Fittings Brass | X | X | ASTM B43, ASTM B135 | Copper | X | X | ASTM B42, ASTM B75, ASTM B88, ASTM B251, ASTM B302, ASTM B447 | ASME B16.15, ASME B16.18, ASME B16.22, ASME B16.26 Ductile-Iron | X | X | AWWA C151 | ASME B16.4, AWWA C110, AWWA C153 Galvanized Steel | X | X | ASTM A53 | Corzan (IPS) Sch. 80 CPVC | | X | ASTM F441, ASTM D1784 | ASTM F439, ASTM F437, ASTM D1784, ASTM F1970 Malleable Iron | X | X | | ASME B16.3 PE (Outside Only) | X1 (UP TO METER) | | ASTM D2239, ASTM D2737, ASTMD3035, AWWA C901, CSA B137.1 | ASTM D2609, ASTM D2683, ASTM D3261, ASTM F1055, CSA B137.1 PE-AL-PE | X | X | ASTM F1282, CSA B137.9 | ASTM F1282, ASTM F1974, CSA B137.9 PEX | X | X | ASTM F87 , ASTM F877, CSA B137.5 | ASTM F877, ASTM F1807, ASTM F1960, ASTM F1961, ASTM F2080, ASTM F2159, CSA B137.5 PEX-AL-PEX | X | X | ASTM F1281, CSA B137.10, ASTM F2262 | ASTM F1281, ASTM F1974, ASTM F2434, CSA B137.10 PVC (Outside Only) | X1 | (ALLOWED TO METER) | AWWA C900 | AWWA C-110 Stainless Steel | X | X | ASTM A269, ASTM A312 | PP | X | X | ASTM F 2389 CSA B 137.11 | ASTM F 2389 CSA B 137.11 1For Building Supply or cold-water applications. All water services constructed of polyethylene (PE) or PVC pipe shall have number 12 tracer wire attached to the service and connected to the curb stop or meter yoke in the meter pit, and stubbed up to the service isolation valve inside the building on private water services. (Exception: not required on rural water services.) (: Ord. 20525 §48, August 21, 2017).
(Ord. 21817 §23; December 15, 2025)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.