For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 24.12.201 — Section 408.3 Amended; Individual Shower and Tub-Shower Combination Control Valves

Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.12.201

Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/360b6f24-fe82-40c7-84e5-622db5348f6e

24.12.201 Section 408.3 Amended; Individual Shower and Tub-Shower Combination Control Valves.

Section 408.3 of the Uniform Plumbing Code is amended to read as follows: 408.3 Individual Shower and Tub-Shower Combination Control Valves. Showers and tub-shower combinations shall be provided with individual control valves of the pressure balance, thermostatic, or combination pressure balance/thermostatic mixing valve type that provide scald and thermal shock protection for the rated flow rate of the installed showerhead. These valves shall be installed at the point of use and comply with ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1. 408.3.1 Gang showers. Where gang showers are supplied with a single temperature-controlled water supply pipe, it shall be controlled by a mixing valve that complies with ASSE 1069. 408.3.2 Temperature Limiting. The maximum water temperature discharging from an individual showerhead shall be limited to 115°F (49°C) by one of the following methods: (1) 1. A shower or tub/shower combination valve conforming to ASSE 1016/ASME A112.1016/CSA B125.16 where either: (a) a. The valve is field-adjusted to the required maximum temperature, or (b) b. The handle position, stop, or temperature limiting control is set in accordance with the manufacturer's instructions to the required maximum temperature. (2) 2. For gang showers supplied by a single water supply pipe, a mixing valve that conforms to ASSE 1069 that is field-adjusted to the required maximum temperature. (3) 3. A limiting device conforming to either ASSE 1070/ASME A112.1070/CSA B125.70 or CSA B125.3. (4) 4. A temperature actuated flow reduction device conforming to ASSE 1062. (: Ord. 20525 §40, August 21, 2017).

(Ord. 21817 §13; December 15, 2025; Ord. 21176 §30; December 13, 2021)

Ask a question about Lincoln law

Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.