24.12.705 Appendix E 7 Amended; M/H Lot Drainage Inlet and Lateral.
Appendix E 7 of the Uniform Plumbing Code is amended to read as follows: (a) Size. Each lot shall be provided with a drainage inlet not less than four (4) inches in diameter. (b) The lateral line from the inlet to the sewage drain line shall slope at least one-fourth (1/4) inch per foot All joints shall be watertight. (c) All materials used for drainage connections between a M/H and the lot drainage inlet shall be semi-rigid, corrosion resistant, non-absorbent and durable. The inner surface shall be smooth. (d) Provision shall be made for plugging or capping the sewage drain inlet when a M/H does not occupy the lot. Surface drainage shall be diverted away from the inlet. The rim of the inlet shall extend not more than four (4) inches above ground elevation.
(Ord. 20525 §123, August 21, 2017)