24.12.400 Section 906.7 Amended; Frost or Snow Closure.

Section 906.7 of the Uniform Plumbing Code is amended to read as follows: 906.7 Frost or Snow Closure. Where frost or snow closure is likely to occur in locations having minimum design temperature below 0°F vent terminals shall be a minimum of three (3) inches in diameter but in no event smaller than the required vent pipe. The change in diameter shall be made inside the building at least twelve (12) inches below the roof and terminate not less than twelve (12) inches above the roof, or as required by the Authority Having Jurisdiction.

(Ord. 20525 §79, August 21, 2017)