24.12.395 Section 906.6 Amended; Lead.

Section 906.6 of the Uniform Plumbing Code is amended to read as follows: 906.6 (See Table 1401.1) Sheet lead shall be not less than the following: For safe pans – not less than 2 1/2 pounds per square foot or 1/16 inch thick. For flashings or vent terminals – not less than 2 1/2 pounds per square foot or 1.2 mm thick. Lead bends and lead traps shall not be less than one-eighth (1/8) inch wall thickness.

(Ord. 20525 §78, August 21, 2017)