§ 24.12.395 — Section 906.6 Amended; Lead
Lincoln, Nebraska Municipal Code (enCodePlus online edition as published 2026-11-08 (history notes seen through Ord. 21775, Sept. 15, 2025)) · Lincoln Municipal Code § 24.12.395
Corpus is an independent public-information project, not the official City of Lincoln website. Stable reference: corpuslaw.us/code/a5736ba2-6097-4ae7-8631-242c67adfc77
24.12.395 Section 906.6 Amended; Lead.
Section 906.6 of the Uniform Plumbing Code is amended to read as follows: 906.6 (See Table 1401.1) Sheet lead shall be not less than the following: For safe pans – not less than 2 1/2 pounds per square foot or 1/16 inch thick. For flashings or vent terminals – not less than 2 1/2 pounds per square foot or 1.2 mm thick. Lead bends and lead traps shall not be less than one-eighth (1/8) inch wall thickness.
(Ord. 20525 §78, August 21, 2017)
Ask a question about Lincoln law
Corpus searches the Lincoln sections it holds and shows the ones that match, with their citations. Free, no sign-in.
