§ 870-243 — Lighting
Code of the City of Camden, New Jersey · Camden City Code § 870-243
Corpus is an independent public-information project, not the official City of Camden website. Stable reference: corpuslaw.us/code/b10de3a1-4d2a-4f40-ba4c-09cceafcb54f
§ 870-243: Lighting.
A. General requirements. (1) All exterior lights shall be designed, located, installed and directed to prevent light pollution and objectionable light, glare and light trespass across property lines. (2) All exterior lights, including streetlights and parking are lighting, shall be full cut-off type fixtures and are encouraged to be 85° full cut-off type fixtures. Streetlights shall be high-pressure sodium, low-pressure sodium, or metal halide, unless otherwise determined by the City that another type is more efficient. Streetlights along residential street shall be limited to seventy-watt high-pressure sodium (HPS) lights. Streetlights along nonresidential streets or at intersections shall be limited to 100 watt hps, except that lights at major intersections along state highways shall be limited to 200 watt hps. If the City permits a light type other than high-pressure sodium, then the equivalent output shall be the limit for the other light type. (3) All lighting shall be recessed sufficiently so as to ensure that no light source is visible from or causes glare on public rights-of-way or adjacent or surrounding properties. (4) Shielding and/or cutoff optics shall be required in all installations. (5) All lighting shall be shielded to prevent glare to pedestrians and bicyclists. (6) Luminaires shall be provided with hoods to prevent uplighting. (7) No lighting shall shine directly or reflect into windows or onto streets and driveways in such a manner as to interfere with driver vision. (8) Pedestrian-scale bollard-type lighting may be placed along walks and at building entrances. (9) Illumination levels and uniformity shall be in accordance with current recommended practices of the illuminating Engineering Society. Recommended standards of the Illuminating Engineering Society shall not be exceeded. (10) All outdoor lighting systems shall be designed and operated so that the area 10 feet beyond the property line of the premises receives no less than 0.25 (one quarter) of a footcandle of light from the premises' lighting system. (11) Outdoor light fixtures for purposes of private, commercial, or industrial usage shall not be attached or mounted to public property (i.e., buildings, utility poles, telephone poles, streetlights, road and/or street signs). Furthermore, these fixtures shall not tap or extend power from sources servicing public lighting and/or power devices. (12) Outdoor recreational and sports facility lighting shall be shielded from public view, as observed from outside the playing field. Such lighting shall have directional and glare control devices, when necessary, to comply with Subsection B. Lamps and/or light sources shall not be visible from residential properties. (13) Underground wiring required. (a) All electric, telephone, television, cable, optical and other similar utilities, both main and service lines servicing new developments, shall be provided by underground wiring within easements or dedicated public rights-of-way, installed in accordance with the prevailing standards and practices of the utility or other companies providing such services. (b) Lots that abut existing easements or public rights-of-way, where overhead electric or telephone distribution supply lines and service connections have heretofore been installed, may be supplied with electric and telephone service from those overhead lines, but the service connections from the utilities' overhead lines shall be installed underground. (14) Outdoor lighting. (a) Light distributions generated by light fixtures shall be confined to the property on which they are installed. (b) Outdoor light fixtures properly installed and maintained shall be directed so that there will not be any direct glare source visible from any adjacent residential property. (c) Light fixtures installed within any setback area, including front, rear or side yard setbacks, shall contain shielded devices to prevent light spill and glare upward and onto adjacent properties. (15) Standards for illumination. (a) The minimum level of lighting along any portion of walkway not part of a parking lot shall be not less than 0.5 footcandle. The maximum level of lighting along any portion of walkway not part of a parking lot shall be not greater than one footcandle. (b) The maximum mounting height of exterior lighting shall conform to the following schedule: Building Height(feet) | Maximum Fixture Mounting Height(feet) Up to 24 | 16 25 or greater | 25 B. Light trespass (nuisance light). All light fixtures, except streetlighting maintained by a governmental authority, shall be designed, installed and maintained to prevent light trespass, as specified below. (1) Facade lighting on schools and other public buildings or incident illumination occurring above the height of five feet above the property line of the subject property shall not exceed 0.1 footcandle in a vertical plane on residentially zoned property. (2) Outdoor light fixtures properly installed and thereafter maintained shall be directed so that there will not be any direct glare source visible from any property. (3) Light fixtures near adjacent property may require special shielding devices to prevent light trespass. C. Streetlighting. (1) Streetlighting shall be installed at no cost to the City by a developer in locations approved by the City Engineer, as the case may be. For residential subdivisions, streetlighting shall be installed, prior to the issuance of any certificate of occupancy, along all roadways necessary to ensure at least one route of illuminated access for any occupied structure. (2) Operating expenses for residential subdivision lighting shall be assumed by the City when 50% of the section is occupied. (3) Luminaire mounting height shall not exceed 25 feet above grade. (4) Pole-mounted street luminaries shall be installed on one side of the street at 300-foot intervals unless the presence of vertical and/or horizontal curves or factors relating to specific types of development necessitates a closer interval. In residential subdivisions, the poles shall be placed, to the greatest extent possible, in line with shared property boundaries. Deviations from the spacing interval shall be approved by the Planning Board or City Engineer, as the case may be. (5) On residential streets, seventy-watt high pressure sodium (HPS) luminaires shall be provided with at least one 100-watt high pressure sodium (HPS) luminaire being provided at each street intersection. On minor collector and major collector streets, 100-watt high pressure sodium (HPS) luminaires shall be provided along the street with 150-watt high pressure sodium (HPS) luminaires being provided at intersections. D. Parking area lighting. (1) Sufficient illumination shall be provided for all off-street parking, loading and pedestrian areas so as to enable the safe movement of persons, vehicles, and provide for security. (2) The minimum level of lighting in any portion of a parking lot shall be not less than 0.25 footcandle. The average horizontal illumination level of lighting within the parking lot shall be not less than 1/2 footcandle nor greater than two footcandles. The maximum level of lighting in any portion of the parking lot shall be not greater than three footcandles, except directly under light fixtures where a maximum of five footcandles is permitted. (3) The minimum level of lighting at any ingress or egress portion of a parking lot shall be not less than one footcandle. (4) Poles installed within parking areas shall be aluminum with a brushed finish and shall be identical in color to poles located along the road that abut the parking area. E. Buildings and other vertical structures. (1) Lighting fixtures shall be carefully located, aimed, and shielded so that light is directed only onto the building surface. Lighting fixtures shall not be directed toward adjacent streets or roads. (2) Lighting fixtures mounted on the building and designed to "wash" the building surface with light are preferred. (3) To the extent practicable, lighting fixtures shall be directed below and horizontal rather than above the horizontal. F. Lighting of walkways/bikeways and parks. (1) The walkway, pathway, or ground are shall be illuminated to a level of no more than 0.5 footcandle. (2) The vertical illumination levels at a height of five feet above grade shall be no more than 0.5 footcandle. (3) Lighting fixtures shall be designed to directed light downward, and light sources shall have an initial output of no more than 1,000 lumens. G. Lighting of gasoline station/convenience store aprons and canopies. (1) Areas on the aprons away from the gasoline pump islands used for parking or vehicle storage shall be illuminated in accordance with the requirements for parking areas set forth elsewhere in this section. If no gasoline pumps are provided, the entire apron shall be treated as a parking area. (2) Areas around the pump islands and under canopies shall be illuminated so that the minimum horizontal illuminance at grade level is no more than 5.5 footcandles. The ratio of average to minimum illuminance shall be no greater than 4:1. This yields an average illumination level of no more than 22.0 footcandles. (3) Light fixtures mounted on canopies shall be recessed so that the lens cover is recessed or flush with the bottom surface of the canopy and/or shielded by the fixture or the edge of the canopy so that light is restrained to no more than 85° beyond the vertical plane. (4) Light shall not be mounted on the top or sides of the canopy, and the sides of the canopy shall not be illuminated. H. Outdoor lighting energy conservation. (1) All outdoor lighting not essential for safety and security purposes or to illustrate changes in grade or material shall be activated by automatic control devices and turned off during nonoperating hours. (a) Exterior retail and merchandise display lighting, i.e., automobile dealerships, nurseries/garden markets, shall be turned off between the hours of 10:00 p.m. and 6:00 a.m. Reduced levels of lighting in interior show or display windows may remain on for security purposes; provided, however, that these levels shall not exceed 25% of the normal artificial lighting levels in the interior display or show windows. (b) Exterior lighting for recreational areas, athletic fields and courts shall not remain on after 10:00 p.m., except for exterior lighting located within and serving accredited educational institutions, which shall not remain on after 11:00 p.m. (c) Exterior security lighting shall be classified as one of the following: [1] Lighting which is essential to deter vandalism and/or break-ins; this lighting shall be limited to exterior door locations. Fixtures used for normal operations at these locations must remain on, the fixtures shall be outdoor enclosed lighting fixtures. If windows areas present possible break-in locations, reduced levels of interior lighting which is situated around the window may remain on as a night light source to illuminate a window. Night light levels shall not exceed 25% of the normal interior artificial lighting levels around the windows. [2] Normally off lighting that is activated by a sensor or detector. Typically, discharge lamp sources such as sodium vapor, mercury vapor, and metal halide are not instant start. Therefore, considerations should be given to using other lamp sources such as incandescent, tungsten halogen, and florescent which can be used for immediate activation. Normally off lighting activated by sensors or detectors shall be directed towards the vertical surfaces of buildings or objects of concern and shall not remain on for greater than five minutes after activation. [3] Lighting that remains on for surveillance cameras. This lighting shall be confined to vertical building surfaces along the perimeter of a site, i.e., walls, trees, bushes. Illuminance levels for this lighting shall be coordinated with, and not exceed, the minimum illuminance threshold of the cameras being used. This data shall be provided with the submission of the plans, in accordance with Subsection I below. Surveillance cameras used in conjunction with outdoor lighting shall be require the minimum illuminance thresholds reasonably available. (2) All lighting shall be designed to prevent misdirected or excessive artificial light and to maximize energy efficiency. I. Submission of plans. (1) Description of outdoor lamp/luminaire combinations including component specification such as lamps, reflectors, optics, angle of cutoff, supports, poles and include manufacturer's catalogue cuts. (2) Locations and description of every outdoor enclosed light fixture and hours of operation, their aiming angles and mounting heights. (3) The initial horizontal and vertical illuminance shall be illustrated in footcandles (before depreciation). Illustrate relamping and cleaning cycles to arrive at maintained values of illumination. (a) Maximum. (b) Minimum. (c) Average, during operating and nonoperating hours. (d) Average to minimum uniformity ratio. (4) Photometric data, such as that furnished by the manufacturer, showing the angle of light emission and the footcandles on the ground. (5) Additional information as may be required by the City in order to determine compliance with this chapter. J. Prohibited lighting characteristics. (1) The use of outdoor strobe lighting is prohibited. (2) Outdoor lights that flash, pulse, rotate, move or simulate motion are not permitted. (3) Outdoor lighting that could interfere with the safe movement of motor vehicles is not permitted. (4) Searchlights or flashing or animated signs are prohibited. (5) Bad lighting fixtures, i.e. "wallpack" type, an "acorn" luminaire that generates a lot of glare and spot-light, lights that have more than 3% or 4% of the total lamp lumens rising upward above the horizon, head luminaire fixtures, floodlights, and spotlights. (6) Lighting that significantly alters nighttime view sheds or vistas from existing residential or public properties are prohibited. (7) Newly installed fixtures, which are no full-cutoff fixtures. (8) Lighting which presents a clear hazard to motorists, cyclists, or pedestrians. (9) The use of laser source light or any other similar high intensity light for outdoor advertising or entertainment is prohibited. K. Lighting commercial zone. Streets luminaires and poles installed within the Commercial Zone shall be of an ornamental variety and be the same or substantially the same as, or compatible with existing ornamental street luminaires and poles within one block or either side of the parcel being improved. L. Temporary lighting. Temporary lighting that conforms to the requirements of this chapter shall be allowed. Nonconforming temporary exterior lighting may be permitted by the Zoning Officer/Administrative Office only after considering the public and/or private benefits which will result from the temporary lighting, any annoyance or safety problems that may result from the use of the temporary lighting, and the duration of the temporary nonconforming lighting. The applicant shall submit a detailed description of the proposed temporary nonconforming lighting to the Zoning Officer/Administrative Officer. M. Towers. All radio, communication, and navigation towers that require lights shall have dual lighting capabilities. For daytime, the white strobe light may be used, and for nighttime, only red lights shall be used. N. Exemptions and exceptions. (1) Federally funded and state-funded roadway construction projects are exempted from the requirements of this chapter only to the extent it is necessary to comply with federal and state requirements. (2) Fossil fuel light produced directly or indirectly by the combustion of natural gas or other utility-type fossil fuels is exempt from the provisions of this chapter. (3) Full cutoff streetlighting, which is part of a federal, state, or municipal installation. (4) Holiday lighting. (5) Lighting of sports facilities or stadiums prior to 11:00 p.m. illumination after 11:00 p.m. is also permitted if it is necessary in order to conclude a recreational, sporting or other scheduled activity which is in progress prior to that time. (6) Specialized lighting necessary for safety, such as navigated lighting, or temporary lighting associated with emergency operations, road hazard warnings, etc. (7) Traffic control signals and devices.
Ask a question about Camden law
Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.
