§ 870-229 — Stormwater collection and management-sanitary/combined sewer

Code of the City of Camden, New Jersey · Camden City Code § 870-229

Corpus is an independent public-information project, not the official City of Camden website. Stable reference: corpuslaw.us/code/30a6826b-2dae-4e4d-9010-08289250bed1

§ 870-229: Stormwater collection and management-sanitary/combined sewer.

Except as supplemented below, stormwater collection and management shall be designed in accordance with the standards set forth in the City Stormwater Ordinance, Stormwater Management Plan, and the New Jersey Residential Site Improvements Standards (RSIS), N.J.A.C. 5:21-7 et seq., for both residential and nonresidential development. Any requests for "de minimus exceptions" to the New Jersey Residential Site Improvement Standards requirements, or waivers from the ordinance shall be placed in writing. A. Runoff standards. (1) For runoff computation purposes, in the post-development condition all nonresidential lawn areas, including open space areas, commercial developments, etc., are to be assumed to have grass cover in fair condition (grass cover 50% to 75%), unless otherwise approved. (2) Computations for proposed conditions shall not assume a wood or brush condition, unless portions of the property are deed restricted to remain in a natural condition. (3) Calculations should be provided showing the derivation of runoff coefficients or curve numbers, time of concentrations, flows to each inlet and flows through the conveyance system. (4) Where excessive gutter flows are expected, calculations should demonstrate that the spread of flow will not exceed six feet for the ten-year design storm. (5) No land in the City shall be developed so that: (a) The drainage of adjacent areas is adversely affected. (b) Soil erosion during and after development is increased over what naturally occurs there. (c) The natural drainage pattern of the area is significantly altered. (d) Soil absorption and groundwater recharge capacity of the area is decreased below what occurs under existing conditions. (e) Wetland areas located within the subject property and in immediately adjacent properties are deprived of their water supply provided by surface runoff. B. Pipelines. (1) Class III reinforced concrete pipe may be used, provided that a minimum of two feet of cover is maintained. Otherwise, Class IV or Class V reinforced concrete pipe shall be used. (a) All storm sewer or combined sewer main twenty-four inches in diameter or greater within the City right-of-way shall be RCP. (b) All sanitary sewers shall be polyvinyl chloride (PVC). Polyvinyl chloride pipe shall be made from Class 12454-B materials or better in accordance with ANSI/ASTM D1784 and fittings shall have an SDR classification of 35. PVC pipe and its accessories shall conform to the requirements of the following with a minimum pipe stiffness of 46 psi at a maximum deflection of 5%: ANSI/ASTM D 3034 (four inches to 15 inches). ANSI/ASTM F 679 (18 inches to 27 inches). (c) All storm and sanitary/combined sewer service above six-inch diameter shall tie into the sewer main with a manhole. Sewer laterals six inches and less may tie in directly to the sewer in a manner approved by the City. Where a connection to a manhole is required, manhole bench and channel may require modification. (d) All direct connections to existing combined sewer and sanitary sewer shall be made with an "Insert a Tee" or approved equal. (e) All newly completed combined/storm/sanitary sewer shall be televised prior to final acceptance and/or completion of project. (f) Pressure testing of all sanitary sewer (including RCP) shall be performed in accordance with the City manual. RCP sewers above 24 inches in diameter shall be joint tested in accordance with ASTM. (g) Pipe bedding for all water mains shall be Type 5. Pipe bedded in compacted granular material to center line of pipe. Compacted granular material to top of pipe (approximately 90% standard proctor, AASHTO T-99) (see attachment details). (h) Select fill for water/sewer trench installation shall be dense graded aggregate (DGA) I-5, in accordance with the specification subsection 901.08 of the NJDOT standard specification, and conform to the following table: Sieve Size | Percent Passing 2-inch | 100 3/4-inch | 55 to 90 No. 4 | 25 to 60 No. 50 | 5 to 25 No. 200 | 3 to 12 (i) Air release valve shall be installed at high points of the water main. (j) All water mains shall be at least eight inches in diameter. (k) Thrust blocks and restraints shall be installed at all bends and fittings. Thrust blocks shall have twenty-eight-day strength of 4,000 PSI. (l) Each building connection requires a curb cleanout. Refer to City-approved details. (m) The City shall require that sewer service connections to be re-used be televised to verify the integrity and that the pipe is free from any defects. (n) The size, material, depth, condition, direction of flow and any other relevant conditions of the existing City sewer to which you plan to connect must be field-verified by the developer to determine if said connection is physically possible and practical. In addition, manhole inverts and rim elevation must be shown on plans. The verification is to be included on the plans for the project. (o) Circular hole saws which are approximately sized or hand drills must be used to make the opening in the existing sewer to receive the laterals. All debris must be removed and not allowed to fall into pipe. (p) Proposed manholes constructed in the public row on existing or proposed City sewer shall be furnished with concentric manhole covers approved by the City. (q) Storm inlets which are connected directly to City combined sewers must be furnished with a sump and trap per City standard details. (r) The City has combined sewer system which surges during wet weather periods resulting in possible sewage back-ups through the plumbing fixture below street level. This possibility must be addressed during the design/construction phase. (s) A drop manhole connection shall be used where there is a difference in elevation of two feet or greater. Refer to City details. (t) Test pits must be performed at the developers expense during the design phase of the project to ensure that the proposed sewers and sewer services may be constructed as proposed without conflicting with the underground utilities or structures. (u) All existing sewer mains and sanitary lateral to be abandoned must be removed from the ground. Catch basins and manholes must be removed from the ground. (v) The system designer is also responsible for compliance with the applicable regulations of the New Jersey Administrative Code, local codes, NJDEP Rules and Regulations governing the treatment works approval program, local codes and ordinances, federal and state regulations, etc., in addition to other requirements that may be imposed by the City. (2) Corrugated metal pipe is prohibited. (3) Corrugated polyethylene pipe (and other similar material) is prohibited in the roadway right-of-way for nonresidential developments and discouraged in residential developments. Said piping is acceptable in off-road areas. (4) The normal manning roughness coefficient established under N.J.A.C. 5:21-7 shall be used for design. (5) Pipelines shall be no closer than 10 feet to existing or proposed trees and shall be shown on landscaping plan. (6) Crowns shall be matched across structures. (7) All RCP shall be lined on the interior with a coat tar epoxy seal coat with a minimum of four mils in thickness (DFT). (8) An as-built plan shall be required on all completed water and sewer mains. The as-built plan shall be based on a survey by a licensed New Jersey professional land surveyor. An electronic format of the same in compliance with the City ordinance shall also be submitted. (9) All RCP from 24 inches up to and including 72 inches diameter shall conform to ASTM C76, minimum pipe class IV, Wall B. (10) All pipe shall be manufactured and supplied without lifting holes. (11) All collapsed combined brick sewer mains shall be replaced with an equivalent size RCP. All connections between the new pipe and the existing brick sewer shall be made as shown on the Division of Capital Improvement and Project Management connection detail sheet. (12) Cured-in-place sewer pipe liner shall be a flexible tube made from one or more layers of polyester felt lined on both sides with a polyurethane or polyvinyl chloride membrane materials bonded to the felt and impregnated with a liquid thermosetting resin. (13) Cured sewer pipe liner shall conform to the following minimum standards: Cured Liner Standard Results Tensile Stress ASTM D-638 3,000 PSI Flexural Stress ASTM D-790 4,500 PSI Flexural Modulus of Elasticity ASTM D-790 250,000 PSI (14) All liners shall be fabricated to a size that when installed will neatly fit in the internal circumference of the sewer pipe. The liner shall be designed for the required external soil and hydrostatic pressures and for internal pressures. The thickness of the liner shall be in accordance with the manufactures recommendations. (15) Video sewer inspections, infiltration/exfiltration testing and pipe alignment testing shall be performed on all new sewer prior to acceptance and/or dedication. C. Inlets, manholes and cutlets. (1) Drainage structures shall be in accordance with N.J.A.C. 5:21-7. (2) No person in control of private property (except a residential lot with one single-family house) shall authorize the paving, repairing (excluding repair of individual potholes), resurfacing (including top coating or chip sealing with asphalt emulsion or thin base of hot bitumen), reconstructing or altering any surface that is in direct contact with an existing storm drain inlet on that property unless the storm drain inlet either: (a) Already meets the design standards of N.J.A.C. 5:21-7.4. (b) Is retrofitted or replaced to meet the standards on N.J.A.C. 5:21-7.4 (3) Manhole frames and covers are to provide for a thirty-inch clear-opening at the cover in order to allow easier access under confined space entry requirements, Campbell Foundry Pattern Number 1012B or NJDOT approved equal. (a) Manhole covers shall be a solid type marked with "SEWER." (b) No "doghouse" manhole shall be permitted on any City right-of-way and roadway. (c) All catch basins shall have traps suitable for preventing floating debris from entering the sewer line and for creating an effective water seal. Catch basin traps shall be East Jordan Iron Works, No. 5924, Neenah Foundry (R- 700), or approved equal. (d) All new manholes and catch basins shall have an exterior coating of Carboline Coal Tar Epoxy 300M, or equal, two coats. Each manhole base shall be provided with circular openings at the required locations and elevations for the proper connection of all pipes. The flexible connections shall be A-lok Flexible Connector by A-lok Products, or equal. (e) Each inlet box shall be provided with circular openings at the required locations and elevations for the proper connection of all pipes. The circular connections shall be sealed with a flexible seal assembly such as G3- Flexible Connector by A-lok Products, Inc. or approved equal. (f) The strength of precast concrete for inlets and manholes shall be equal to or exceed 4000 psi. (4) Bicycle-safe frames and grates shall conform with the Campbell Foundry Pattern Numbers 1218, 3405 or 3424, or NJDOT approved equal. (5) The grate shall be set two inches below the normal gutter grade, except along collector or higher order streets with no parking. The surface of the paving adjacent to the inlets shall be constructed to blend into the lowered gutter grade at the inlet in such a manner that a sudden dropoff or dip at the inlet will not be created. (6) Curb inlets shall not be placed on the radius section of the curb. (7) Inlets shall be installed at all intersections so as to minimize gutter flows across the intersection. Storm drains crossing a corner shall not encroach on adjacent property. (8) Concrete headwalls or flared end sections shall be provided at all pipe discharges and shall be equipped with toe walls to prevent undercutting of the structure, unless otherwise approved. (9) The minimum median stone diameter (d5O) for riprap aprons, scour holes and channels shall be six inches, unless otherwise approved by the City Engineer. (10) Scour holes shall not be used near residential developments. D. Grass swales. (1) Grassed swales shall have a minimum 2% grade. (2) Maximum velocities in grass swales shall not exceed the erosive velocity for the soils present at the site. (3) Swales in residential developments shall be located as close as practical to the property lines. (4) An easement shall be provided for a swale conveying drainage from more than the immediately adjacent lots. E. Sump pumps. (1) Sump pumps in developments shall be connected to a common header pipe located behind the curbline to carry water by gravity from below all basement floors to storm drains or as approved by the City Engineer, as the case may be. A sump pump may only be used to supplement the underdrain system around the structure. No sump pumps shall be connected to a sanitary sewer system. (2) The header pipe shall be at least six inches in diameter. The size shall be increased no less than 10% in cross-section areas for each 1,000 feet of longitudinal drain. (3) Cleanouts shall be provided at all changes in line or grade; however, the distance between cleanouts shall not exceed 450 feet. In no case shall cleanouts be permitted in sanitary manholes. Cleanouts are to be located under an approved cover or vault. One cleanout with a screw-type cap shall also be provided in each basement floor in line with the pipe connecting the perimeter house under drain to the under drain in the street. (4) The system shall be separated no less than five feet vertically and two feet laterally from the sanitary sewer. (5) The system may be constructed of PVC, HDPE or DIP material. (6) The applicant may seek waiver of this requirement based on the nature of the development, size and location of lots or the relationship of the basement floor to the estimated seasonal high groundwater table. In the latter instance, sufficient soil tests shall be made to verify the estimated seasonal high groundwater table. F. Underdrains. (1) Where warranted to dewater the subgrade of roadways, basins or other facilities, underdrains are to be installed and connected to an approved drainage structure. (2) Underdrains shall consist of perforated pipe installed in a stone envelope. A filter fabric compatible with the soil condition shall be installed. (3) The end of an underdrain system shall be equipped with a cleanout. A separate cover or vault shall house the cleanout. Said cover or vault shall be designed to prevent traffic loads from impacting the riser pipe. G. Stormwater management systems (general). (1) Detention basins are preferred over retention (infiltration) basins or ponds. If the latter are proposed, justification shall be provided. (2) Basins are to be provided on lots dedicated to said use and are not to be installed on lots having thereon the following types of residential units: (a) Single-family detached. (b) Single-family attached duplex. (c) Single-family attached townhouse. (3) Multiple basins within a development are discouraged and shall be justified based on physical constraints. (4) Basins near residential uses or that are readily visible to the public shall be aesthetically designed. Side slopes 4:1 or flatter shall be provided where practical. (5) Basin side slopes of 10:1 or flatter may be located within an open space area intended to be dedicated to public use, provided the system is designed for this area to be dry within 24 hours after a rain event. (6) In order to aid in the evaluation of unforeseen changes in the contributing drainage shed, the plans shall include a tabulation of basin design parameters which shall provide runoff coefficients; impervious coverage; drainage shed areas; influent and effluent flow rates, water levels and storage volumes for the critical storm events; and any other pertinent information that may impact future design. (7) Adequate dimensions and grade information for the basins shall be provided to allow for proper construction. (8) A seed mixture appropriate for the wet conditions, soil types and maintenance schedule should be specified. (9) A maintenance schedule shall be provided for all systems. (10) Privately maintained basins will not be maintained by the City; however, an easement shall be provided to allow the City to enter, inspect and maintain the basins in an emergency situation, with the costs being charged to the owner. (11) All basins, regardless of ownership, shall have a dedicated access from a public right-of-way. The access should include a stabilized surface suitable for the passage of maintenance and inspection equipment and vehicles. This may be waived when adjacent to a public roadway. (12) Soil borings driven at least four feet below the basin bottom are to be provided with the application for approval. At least two borings shall be provided, plus one additional boring for each 20,000 square feet of surface area above the first 20,000 square feet. H. Detention basins. (1) The bottom of all detention basins shall be graded at a minimum 2% slope, unless underdrains or a low-flow channel is provided. (2) Reinforced concrete low-flow channels shall have grades of 1% or greater. Channel material shall provide a hard and stable surface for maintenance equipment but shall allow infiltration and vegetative growth through the channel in order to enhance the water quality aspect of the basin. (3) A two-foot separation should be provided between the basin bottom and the estimated seasonal high groundwater table. (4) Low, suitable fencing and landscaping shall be provided between the basin and residential lots. (5) A low-flow channel shall also be provided when parts of the contributing piping system intercepts groundwater. (6) For commercial developments, a gas/oil separator shall be provided prior to discharge of stormwater into the detention basin. (7) All detention basins are to be landscaped as required by § 870-244G. I. Retention (infiltration) system. (1) Calculations demonstrating that the basin will dewater within 18 hours after the end of the rainfall event shall be provided. (2) Infiltration rates shall be based on either field percolation tests or laboratory permeability tests performed on undisturbed soil samples. (3) A three-foot separation should be provided between the basin bottom and the estimated seasonal high groundwater table. (4) Split rail fencing with wire mesh shall be provided for the full perimeter. (5) The maintenance schedule shall require scarifying and reseeding of the soils on a regular basis (not to exceed five years) or when infiltration rates decrease such that the system retains water for 48 hours. (6) Retention basin bottoms shall be kept clean of leaves at all times. (7) Post-construction percolation or permeability test will be required at retention basins to verify that the design infiltration rates have been obtained. (8) At no time after final basin grading and permanent stabilization should any equipment be allowed to operate within retention basins which could smear or compact the soils leading to a reduction in the percolation rate. This includes mowing and the annual removal of accumulated silt. This does not pertain to the reestablishment of the basin bottom every five years. J. Underground systems. (1) Underground infiltration systems shall only be permitted where the City Engineer, as the case may be, determines the use of aboveground stormwater management systems is impracticable. (2) A means to identify if the system is functioning properly shall be included in the design. (3) Means to access the system for inspection and cleaning shall be provided. (4) Calculations demonstrating that the system will dewater within 18 hours after the end of the rainfall even shall be provided. (5) Infiltration rates shall be based on either field percolation tests or laboratory permeability tests performed on undisturbed soil samples. (6) A three-foot separation should be provided between the basin bottom and the estimated seasonal high groundwater table. K. Lakes, ponds and retention basins. (1) Wet ponds, lakes, etc., used for stormwater management shall have a normal water depth of at least six feet in order to minimize the frequency of eutrophication. (2) Split-rail fencing with wire mesh shall be provided for the full perimeter unless the slope of the embankment and underwater safety ledges obviate the need for such fencing. (3) A program to monitor the condition of the system shall be developed. (4) Sediment calculations/modeling shall be performed to estimate rate of siltation in order to establish a long-range maintenance program. (5) A maintenance fund shall be established for the homeowners' association based on estimated cost of the maintenance and monitoring program. (6) If the system currently exists, laboratory tests shall be performed to establish base conditions. (7) Water depths shall be established for use by emergency personnel and to allow monitoring of sedimentation of the lake. L. Outlet structures. (1) Trash racks are to be provided for orifices less than 12 inches in diameter in systems maintained by the public or by a homeowners' association. Screens may be required for larger openings if deemed necessary for public safety. (2) Trash racks and screens shall consist of noncorrosive material with stainless steel hardware. The bottom of the racks shall be fastened to a concrete slab, and hinges shall be provided for cleaning purposes. The bars shall be vertical to allow for raking of debris from the top of the structure. (3) All exposed concrete shall have a rubbed or brushed finish. (4) All outlet structures readily visible to the public shall have wing walls and shall be located within the embankment area, unless otherwise approved by the engineer. (5) There shall be a minimum 0.1-foot fall across the structure from the invert of the lowest inlet to the invert of the outlet. (6) Outlet structures are to discharge to public systems or through easements on privately held land. M. Emergency spillways. (1) Emergency spillways shall not direct water toward private property. (2) Grassed spillways are to be used when practical. (3) The outlet structure may perform the function of an emergency spillway, provided that the top grate, discharge pipe and receiving system can pass the full 100-year storm event while meeting the criteria of N.J.A.C. 5:21-7. (4) A reduction in the required freeboard may be considered for small basins servicing drainage areas less than 10 acres. N. Water quality. (1) The applicant shall demonstrate compliance with New Jersey Department of Environmental Protection water quality standards. (2) The standards of the New Jersey Department of Environmental Protection Stormwater and Non-Point Source Pollution Control, Best Management Practice Manual shall be incorporated into the design. O. Pervious paving. (1) Previous paving systems may be used to reduce the imperviousness of firm surfaces such as patios, walkways, driveways, fire lanes, and parking areas, for the purpose of reducing surface runoff and increasing infiltration. The pervious paving systems may also be used as inlets and covers for infiltration trenches. Pervious paving can be effective in helping to reduce peak surface runoff rates or in improving the groundwater recharge characteristics of developed sites. (2) Pervious paving requires moderately pervious soil with the depth to the seasonal high water table or bedrock of greater than three feet below grade. Because of the large area over which infiltration occurs, pervious paving minimizes the potential for groundwater mounding or concentrated discharges to groundwater. (3) Because pervious paving recharges surface runoff directly to groundwater, it shall not be used where there is a significant concern for the contamination of surface runoff with dissolved pollutants. In particular, to prevent contamination of drinking water supplies, they shall not be installed in highly pervious and or gravel seams that are directly connected to aquifers, or in hotspot drainage. (4) Pervious paving typically is installed in lieu of or in proximity to runoff-generating surfaces. The best performance is achieved when the up-gradient drainage area is minimized. One strategy is to alternate areas with impervious and pervious paving. In these instances, conventional impervious paving would be reserved for the most heavily trafficked corridors. A wide variety of concrete and brick paving systems are available. These can be combined with conventional pavement to achieve functional and aesthetically pleasing designs. (5) Pervious paving systems are prone to clogging by suspended solids. To reduce the likelihood of clogging, pervious paving should not be used in areas that receive significant amounts of sediment, including mud tracked onto the surface during wet weather and sand or cinders used in snowy conditions. To preserve the long-term performance of pervious paving, it is important to control sources of suspended solids in stormwater before if runoff is discharged onto the paved surfaces. P. Stormwater reports. (1) All reports are to be signed and sealed by a professional engineer. (2) The reports are to contain a table of contents, a narrative, a summary of the findings and the calculations supporting the findings. The pages of the report shall be consecutively numbered. All calculations are to be appropriately labeled. Calculations are to be thorough and shall show the derivation of the various design components. (3) Drainage area maps and soil maps are to be provided. (4) Pipe routing calculations are to be presented in a tabular format.

Ask a question about Camden law

Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.