§ 870-222: Performance standards for all uses.

A. Air quality. No use governed by federal or state air quality regulations shall emit into the air heat, odor, vibrations, noise or any other pollutant which exceeds the most stringent requirements of the applicable federal or state regulations. B. Emissions. In all districts, no use, activity, operation or device shall be established, modified, constructed or used without having first obtained valid permits and certificates from the Bureau of Air Pollution Control, NJDEP pursuant to N.J.A.C. 7:27-8. Specifically, no use, activity, operation or device shall be established, modified or constructed without a valid permit to construct. No use, activity, operation or device shall be operated, occupied or used without a valid certificate to operate control apparatus or equipment. Proof of compliance with this requirement shall be the submission of duplicate copies of the permit to construct and certificate to operate. In addition to the requirements of NJDEP, the following shall also apply: (1) Particulate matter shall not be discharged into the outdoor air in a concentration exceeding 0.03 grain per cubic foot of gas at actual gas conditions unless a minimum of 95% of such particles leaving the process in the stack gas are removed from the gas prior to discharge. However, regardless of degree of gas cleaning, the following provisions shall apply: (a) The concentration of solid particles shall not exceed 0.05 grain per cubic foot at 600° F. and one atmosphere pressure. (b) No more than 3% by weight of the particles discharged shall equal or exceed 44 microns in diameter. (c) No more than 20 pounds of particulate matter per hour shall be discharged into the outdoor air from any single source. (2) Visible emission, such as smoke, the shade or appearance of which is darker than No. 1 on the Ringlemann Smoke Chart, shall not be discharged into the open air from any fuel-burning equipment; provided, however, that smoke emitted during the clearing of a fire box or the building of an new fire, the shade or appearance of which is not darker than No. 2 on the Ringlemann Smoke Chart, shall be permitted for a period or periods aggregating no more than three minutes in any 15 consecutive minutes. C. Toxic and radioactive substances. Emissions of chemicals, gases, components or elements listed as being toxic matter by the American Conference of Governmental Hygienists, New Jersey Department of Labor or the United States Environmental Protection Agency shall not exceed the threshold level. Proof of compliance shall require the submission of copies of certificates or permits from the New Jersey Department of Environmental Protection approving the concentrations, level or loading proposed by the applicant. There shall be no radioactive substances associated with any use. D. Drainage. No stormwater or natural drainage which originates on the property or water generated by the activity (i.e., air conditioners, swimming pools, etc.) shall be diverted across property lines unless transported in an approved or existing drainage system. E. Electronic equipment. All electric or electronic devices are subject to the provisions of federal and state laws and regulations, including 42 U.S.C. 263b et seq., "An Act for the Protection of Public Health and Safety from the Dangers of Electronic Product Radiation,"[1] and the applicable regulations and guidelines promulgated by the Secretary of the Department of Health and Human Services. Electronic products shall be so limited and controlled so that no measurable energy can be recorded at any point beyond the property lines. The applicant, upon request, shall produce certified data wherein measurements made in accordance with the procedures and standards established by the United States Department of Health and Human Services adequately demonstrate compliance with the minimum standards required by law. All other forms of electromagnetic radiation lying between 100 KHz and 10 GHz shall be restricted to the technical limits established in the Federal Community Commission's Rules and Regulations. Additionally, electric or electronic equipment shall be shielded so there is no interference with any radio or television reception at the lot line (or beyond the operator's dwelling unit in the case of multifamily dwellings) as the result of the operation of the equipment. F. Glare. No use shall produce a strong, dazzling light or reflection of a strong dazzling light or glare beyond its lot lines. Exterior lighting shall be shielded, buffered and directed so that glare, direct light or reflection will not become a nuisance to adjoining properties, adjoining units, adjoining districts or streets. G. Heat. No use shall produce heat perceptible beyond its lot lines. Further, no use shall be permitted which could cause the temperature to rise or fall in any body of water, except that this provision shall not apply to any sewage treatment plant which has received approval by the New Jersey Department of Environmental Protection. H. Noise.[2] Noise levels shall be designated and operated in accordance with local regulations and those rules established by the New Jersey Department of Environmental Protection as they may be adopted and amended. (1) Noises shall not exceed 55 dba in residential districts and 65 dba in all other districts measured on or beyond the neighboring use, lot line or district boundaries. (2) Noises such as alarms, sirens, emergency warning devices, motor vehicles, clock bells or church bells are excluded from the above limitations. I. Odor. Odors shall not be discernible at the lot line or beyond. Any process which may involve the creation or emission of any odors shall be provided with a secondary safeguard system so that control will be maintained if the primary safeguard system should fail. J. Ventilation. No use shall obstruct the natural ventilation of adjacent uses nor contaminate the air with excessive heat or odor. Further, no air conditioners or exhaust fans shall be permitted to discharge exhausted air unless set back from all property lines at least 10 feet or equipped with baffles to deflect the discharged air away from the adjacent use. Air conditioners and vents on rooftops shall be screened from view. K. Vibration. Vibration levels shall not exceed a particle velocity of 0.05 inches per second in any district. During the hours of 9:00 p.m. to 7:00 a.m., said velocity shall not exceed 0.02 inches per second in residential districts. L. Visibility. At the intersection of roadways or at any point of entry onto a public roadway, no structure or planting which obscures vision above a height of 2 1/2 feet above grade shall be permitted within a clear sight triangle. M. Storage. All outdoor storage facilities for fuel, raw materials and products stored outdoors shall be enclosed by an approved safety fence and suitable landscaping to screen such areas from public view and must comply with ordinance landscaping and buffering requirements. N. Waste. No materials, wastes or other substances shall be stored or maintained upon a lot in such a manner that natural runoff from such areas on a site with an approved stormwater drainage plan can impair the existing water quality of a stream, watercourse or aquifer more than the primary use intended for the lot.

Ask a question about Camden law

Corpus searches the Camden sections it holds and shows the ones that match, with their citations. Free, no sign-in.