§ 17.36.060 — Performance standards
Code of Ordinances of the City of Elizabeth, New Jersey (Supp. No. 31: codified through Ordinance No. 6138, passed June 24, 2025) · Elizabeth City Code § 17.36.060
Corpus is an independent public-information project, not the official City of Elizabeth website. Stable reference: corpuslaw.us/code/51b95a9d-944f-4547-bca3-878c916c63c3
17.36.060 - Performance standards.
A. General application. Permitted and conditional uses enumerated in any C or M district, and uses accessory thereto, shall be subject to the following performance standards and procedures. B. Procedures Enforcement. 1. Prior to Construction and Operation. Any application for a building permit for a use which shall be subject to performance standards shall be accompanied by a sworn statement filed by the owner of subject property or the operator of the proposed use that said use will be operated in accordance with the performance standards set forth herein. 2. Continued Compliance. Continued compliance with performance standards is required and shall be enforced by the building inspector. 3. Termination of Violation. All violations shall be terminated within thirty (30) days or shall be deemed a separate violation for each day following, and violators shall be subject to fines as set forth herein. C. Regulation of Nuisance Elements. 1. Definition of Nuisance Elements. A nuisance element is any noise, radioactivity, vibration, glare, smoke, odor, air pollution or dust which exceeds the performance standards established under this section. 2. Locations where determinations are to be made for enforcement of performance standards. The determination of the existence of nuisance elements shall be made at: a. Any residential property line, for noise, vibration, glare and dust. b. Anywhere within the city, for elements involving radioactivity, smoke and other forms of air pollution. c. The zone district boundary line, for odor. D. Radioactivity. No activities shall be permitted which cause radioactivity in violation of Title 10, Chapter I, Part 20, Code of Federal Regulations, Standards for Protection Against Radiation, dated June 16, 1957, or any subsequent revision or amendment thereto. E. Noise. 1. At the points of measurement specified in subsection (C)(2), the maximum sound-pressure level radiated in each standard octave band by any use or facility, other than transportation facilities or temporary construction work, shall not exceed the values for octave bands lying within the several frequency limits given in Table I, II and III. The sound pressure level shall be measured with a sound level meter meeting ANSI (American National Standards Institute) S1.4 or the latest revision thereof. 2. Sound level is the measured level of a sound expressed in dB (decibels) re 0.0002 microbar, obtained using a sound level meter. Sound levels include all factors inherent in measuring with a sound level meter including microphone frequency response, amplifier characteristics, meter damping, observer effects and weighting networks. 3. The sound pressure level, in dB (decibels), of sound is twenty (20) times the logarithm to the base ten (10) of the ratio of the pressure of the sound to the reference sound pressure. Sound pressure level is measured with a sound level meter meeting ANSI (American National Standards Institute) S1.4 or the latest revision thereof. 4. No person shall cause, suffer, allow or permit sound from any industrial or commercial operation which, when measured at any residential property line, is in excess of any of the following: a. From 7:00 a.m. to 10:00 p.m. i. Continuous airborne sound which has a sound level in excess of sixty-five (65) dBA. ii. Continuous airborne sound which has an octave band sound pressure level in decibels which exceeds the values listed below in one or more octave bands: Table I Octave Band Center Frequency (Hz) | Octave Band Sound Pressure Level (dB) 31.5 | 96 63 | 82 125 | 74 250 | 67 500 | 63 1,000 | 60 2,000 | 57 4,000 | 55 8,000 | 53 iii. Impulsive sound in air which has an impulsive sound level in excess of eighty (80) decibels. b. From 10:00 p.m. to 7:00 a.m. i. Continuous airborne sound which has a sound level in excess of fifty (50) dBA. ii. Continuous airborne sound which has an octave band sound pressure level in decibels which exceeds the values listed below in one or more octave bands: Table II Octave Band Center Frequency (Hz) | Octave Band Sound Pressure Level (dB) 31.5 | 86 63 | 71 125 | 61 250 | 53 500 | 48 1,000 | 45 2,000 | 42 4,000 | 40 8,000 | 38 iii. Impulsive sound in air which has an impulsive sound level in excess of eighty (80) decibels. c. No person shall cause, suffer, allow or permit sound from any industrial or commercial operation which, when measured at the property line of any other commercial operation, is in excess of any of the following: i. Continuous airborne sound which has a sound level in excess of sixty-five (65) dBA. ii. Continuous airborne sound which has an octave band sound pressure level in decibels which exceeds the values listed below in one ir or more octave bands: Table III Octave Band Center Frequency (Hz) | Octave Band Sound Pressure Level (dB) 31.5 | 96 63 | 82 125 | 74 250 | 67 500 | 63 1,000 | 60 2,000 | 57 4,000 | 55 8,000 | 53 iii. Impulsive sound in air which has an impulsive sound level in excess of eighty (80) decibels. 5. Enforcement of subsections C and E shall be by the department of health, welfare and housing. F. Vibration. No vibration which is detectable without instruments at the points of measurement specified in subsection (C)(2) shall be permitted. G. Glare. No direct or sky-reflected glare, whether from flood lights or from high-temperature processes such as combustion or welding, shall be visible at the points of measurement specified in subsection (C)(2). H. Smoke. No emission of visible gray smoke of a shade equal to or darker than No. 2 on the Power's Micro-Ringelmann Chart, published by McGraw-Hill Publishing Company, Inc., copyright 1954 (being a direct facsimile reproduction of a standard Ringelmann Chart as issued by the United States Bureau of Mines), shall be permitted. Visible gray smoke of a shade equal to No. 3 on the chart may be emitted for not more than three minutes in any fifteen (15) consecutive minutes when a firebox is cleaned or when a new fire is built. I. Odors. No emission of odorous gases or other odorous matter in such quantity as to be readily detectable without instruments shall be permitted. J. Dust. Solid or liquid particles shall not be emitted in concentrations exceeding three-tenths grain per cubic foot of the conveying gas or air. K. Fly Ash. 1. No emission of any fly ash shall be permitted to be discharged from any stack or chimney into the open air in excess of the quantity set forth in the following table. Fly Ash Heat in Fuel Burned (British thermal units per hour) | Rate of Emission (pounds per hour) 1,000,000 | 1 100,000,000 | 100 400,000,000 | 330 1,000,000,000 | 750 2,000,000,000 | 1,365 3,000,000,000 | 1,850 4,000,000,000 | 2,260 5,000,000,000 | 2,640 6,000,000,000 | 2,950 7,000,000,000 | 3,200 8,000,000,000 | 3,410 10,000,000,000 | 3,750 2. For heat content between any two consecutive heat contents, the fly ash limitation shall be as determined by interpolation.
(Prior code § 40-122)
Ask a question about Elizabeth law
Corpus searches the Elizabeth sections it holds and shows the ones that match, with their citations. Free, no sign-in.
