17.36.120 - Principal building regulations.

A. Height limitations shall be maintained as follows at any time a building or other structure is constructed or altered. A basement which rises not more than four (4) feet above grade shall not count as a story. No occupancy of a basement or one-half (½) a story shall be permitted in the city for residential purposes in any zone. 1. In the R-1 residential district, buildings shall be limited to three stories. No occupancy for any purposes (office, storage, residential uses, etc.) shall be permitted above the third story. Building height shall be prevailing or if a prevailing does not exist thirty-eight (38) feet. Building height shall be measured by using the average of the existing grades where the future building will be placed (all four (4) corners and ten (10) feet within that area) and the "roof top" of the structure (peak). 2. In all residential districts except R-4, all commercial districts except C-3 and C-4, building height shall be the same as the R-1 requirements. 3. In the R-4 and C-3 districts, building height shall be limited to sixteen (16) stories and one hundred sixty (160) feet. Residential buildings with four or fewer units to be same as R-1 requirements. 4. In the C-4 and Manufacturing districts, building and other structure height shall be limited to five stories and sixty (60) feet. B. No structures may project above the roof eaves or cornice line except as follows: 1. Decorative elements such as chimneys, church spires, belfries, cupolas, domes and monuments may project fifty (50) percent higher than otherwise limited. 2. Utilitarian appurtenances such as vents and utilities may project not more than two feet unless they are enclosed within parapet walls. 3. Freestanding poles or masts for flags, whip antenna, or light fixtures may extend to one and one-half times the height permitted for buildings. 4. Parapet walls may project not more than four feet plus one-half the setback from the roof edge to a maximum of twelve (12) feet above the roof of the building. 5. Dormers or penthouses may project as necessary to provide clearance for stairways or equipment in vertical shafts.

(Ord. No. 4920, § 9, 10-10-2017; prior code § 40-128)

Ask a question about Elizabeth law

Corpus searches the Elizabeth sections it holds and shows the ones that match, with their citations. Free, no sign-in.