7.27.040 - Installations.
A. General Requirements. The owner of a facility with one or more fats, oil or grease generating activities shall install a grease interceptor. All grease interceptors shall be installed on the premises where fats, oil and grease are used or generated. These facilities are required to install, operate, and maintain an approved type and adequately sized grease interceptor necessary to maintain compliance with the objectives of these regulations. The grease interceptor shall be adequate to separate and remove fats, oil and grease contained in wastewater discharges prior to the public sewer system. B. New Facilities. Newly proposed or constructed facilities, including tenant improvements that change the use classification to a food service establishment, food sales establishment, food processing establishment or a new mixed use development with the potential to generate fats, oil and grease shall: 1. Be required to install, operate and maintain an approved type and adequately sized gravity grease interceptor as necessary to maintain compliance with the requirements described in this chapter, and as necessary to prevent a condition of prohibited discharge; or 2. A hydromechanical grease interceptor may be utilized instead of a gravity grease interceptor if it is demonstrated to the satisfaction of the Health Department that the installation of a gravity grease interceptor is physically impracticable. For the purposes of this determination, "physically impracticable" shall include: (a) The lack of available space on the premises; (b) Unavoidable interference from underground utilities or structures; or (c) Topographical conditions such as slope that unavoidably prevent installation of a gravity grease interceptor. 3. A hydromechanical grease interceptor may be utilized instead of a gravity grease interceptor if the gravity grease interceptor sizing in the currently adopted plumbing code results in an interceptor volume of seven hundred fifty (750) gallons or less. 4. A separate gravity grease interceptor may be provided for each individual unit of a building structure that is proposed for, or could be potentially converted in the future into, a food service, food sales or food processing establishment. The city health department may allow the separate gravity grease interceptors to be installed at a later date, when food service, food sales, or food processing establishments are added through tenant improvements; provided that the side sewer lines leaving the building are designed to functionally accommodate the installation of future interceptors at accessible locations. 5. One or more food service establishments may comply with the requirements of this chapter by use of a shared gravity grease interceptor; provided, however that the food service establishment seeking to establish compliance by means of this section shall demonstrate to the satisfaction of the health department that: (a) It has enforceable rights to utilize shared gravity grease interceptor pursuant to an easement; declaration; covenants, conditions, and restrictions; or similar instrument; (b) The shared gravity grease interceptor is sized as necessary to accommodate the discharges of all food service establishments enjoying rights to use such interceptor; and (c) There is a mechanism providing continued maintenance of such shared gravity grease interceptor. 6. Any food service, food sales, or food processing establishment undertaking a remodel, as defined herein, will be reviewed, and may be considered a new facility for the purpose of this chapter. 7. Implement best management practices to reduce the quantity of fats, oil and grease discharged to the public sewer system. C. Existing Facilities. Existing facilities shall: 1. Implement best management practices to reduce the quantities of fats, oil and grease discharged to the public sewer system. 2. Be permitted to operate and maintain existing grease interceptors; provided, that the equipment is properly sized and in efficient operation condition. 3. Install a properly sized and functioning grease interceptor designed to meet the grease control requirements in this chapter if the facility does not have an existing grease interceptor or an existing grease interceptor is either under-designed or otherwise substandard per the provisions of this chapter. Installation of required improvements must be completed within twelve (12) months of notification by the city. The city building department must approve the proposed plans for the grease interceptor design prior to installation.
(Ord. No. 5166, § I, 4-23-2019)
Ask a question about Elizabeth law
Corpus searches the Elizabeth sections it holds and shows the ones that match, with their citations. Free, no sign-in.