§ 7.27.060 — Standard design requirements
Code of Ordinances of the City of Elizabeth, New Jersey (Supp. No. 31: codified through Ordinance No. 6138, passed June 24, 2025) · Elizabeth City Code § 7.27.060
Corpus is an independent public-information project, not the official City of Elizabeth website. Stable reference: corpuslaw.us/code/96dd58c7-0b9d-4ba5-91f9-890153f4bc91
7.27.060 - Standard design requirements.
A. Standard Requirements—Gravity Grease Interceptors. 1. Each facility is solely responsible for the cost of the grease interceptor installation, inspection, cleaning and maintenance. 2. Gravity grease interceptor sizing and installation shall conform to the requirements contained in the current edition of the New Jersey Plumbing Sub-code or other criteria as determined on a case-by-case basis based upon review or relevant information, including, but not limited to grease interceptor performance, waste stream characteristics, facility location, maintenance needs, and/or inspection needs. Supporting sizing calculations shall be submitted to the governing agency. 3. Gravity grease interceptors shall be designed by a professional engineer licensed in the State of New Jersey using standard engineering principles for sedimentation and flotation in gravity interceptors. The grease interceptor shall have a minimum of two (2) compartments with fittings designed for grease retention. 4. Gravity grease interceptors shall be installed at an outdoor location where it is easily accessible for sample collection, inspection, and cleaning and removal of retained grease. The grease interceptor may not be installed inside a building and the location must meet the approval of the governing agency. 5. Gravity grease interceptors shall be located in the lateral line between all fixtures which may introduce grease into the sanitary sewer and the connection to the public sewer system. Such fixtures shall include but not be limited to sinks, dishwashers, floor drains for food preparation and storage area, mop sinks, and any other fixture which is determine to be a potential source of grease. 6. Gravity grease interceptors must be vented. 7. Gravity grease interceptors shall be equipped with a sampling port at the outlet of the interceptor. Inspection tees and manholes must enable the city to monitor and test the discharge for compliance with utility requirements or to allow monitoring and testing in accordance with the rules and regulations of other federal, state, or local agency having governmental or contractual jurisdiction within the utility service area. 8. Access manholes a minimum diameter of twenty-four (24) inches, shall be provided over each chamber and sanitary tee. The access manholes shall extend at least to the finished grade and be designed to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, cleaning and removal of retained grease and sample collection. Riser maximum shall not exceed sixteen (16) inches. 9. Sanitary wastes shall not be introduced into the gravity grease interceptor. B. Standard Requirements—Hydromechanical Grease Interceptor. 1. Each facility is solely responsible for the cost of the HGI installation, inspection, cleaning and maintenance. 2. HGI sizing and installation shall conform to the requirements contained in the current edition of the New Jersey Plumbing Sub-code or other criteria as determined on a case-by-case basis based on review or relevant information, including, but not limited to grease trap performance, waste stream characteristics, facility location, maintenance needs, and/or inspection needs. 3. HGIs shall be designed using standard engineering principles by a licensed New Jersey Professional Engineer for sedimentation and floatation in gravity separators. Complete plumbing plans and isometric or riser diagrams are required at time of plan check submittal. The plans must be stamped by the professional engineer of record. 4. HGIs shall be installed at a location where it is easily accessible for sample collection, inspection, and cleaning and removal or retained grease. 5. The HGI shall be equipped with a device to control the rate of flow through the unit. The rate of flow shall not exceed the manufacturer's rated capacity recommended in gallons per minute for the unit. 6. Sanitary wastes cannot be introduced into the HGI.
(Ord. No. 5166, § I, 4-23-2019)
Ask a question about Elizabeth law
Corpus searches the Elizabeth sections it holds and shows the ones that match, with their citations. Free, no sign-in.