For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

41:16-6-2 — Zoning Standards

Code of the City of Newark, New Jersey (Newark City Code and Charter current through the 2026-09-23 codification (eCode360 publication NE4043, scraped 2026-11-17)) · Newark City Code § 41:16-6-2

Corpus is an independent public-information project, not the official City of Newark website. Stable reference: corpuslaw.us/code/61c739d2-aae6-40aa-821e-513e1d048696

§ 41:16-6-2: Zoning Standards.

1. General Illumination Standards. a. All exterior areas of a site, except for residential and school structures, shall be illuminated at night in accordance with the standards herein. This shall include, but not be limited to, pedestrian pathways, plazas, courtyards, building entrances, parking and driveway areas, and other outdoor spaces commonly used at night. When such areas are not in active use, lighting shall be sufficient to allow for appropriate surveillance for crime prevention purposes, but shall be designed and installed in such a way as to minimize glare or intrusive light onto adjoining properties. b. All wires and cables used for the provision of lighting from light poles or other freestanding structures shall be underground. c. All exterior lighting fixtures, however mounted, shall be provided with shields as necessary to confine the illumination to the site upon which it is located to the standards set forth herein and to eliminate glare on any adjacent properties and to adjacent streets. 2. Illumination Levels. a. Illumination levels at the property line of a project shall not be more than 0.5 footcandle with the shell pointing downwards at any point when the project is located next to any residential use or residentially zoned property. The illumination levels at the property line of a project adjacent to any other use shall not be more than one footcandle. Illumination levels shall be permitted to exceed one footcandle within the right-of-way at a front property line in order to provide illumination levels as specified in this section at building entrances, pedestrian walkways, access drives, or other required locations. b. Off-street/surface parking areas or lots as well as private roadway areas shall comply with the following requirements: Illumination levels outside the radius of any light pole (with radius equaling the height of the pole) shall range between a minimum of one footcandle and a maximum of five footcandles. c. Access drives for non-residential uses and multifamily housing shall be illuminated with at least 0.5 footcandle. d. Entrances and exits of non-residential structures and multi-family housing shall have a minimum illumination level of one footcandle and a maximum level of five footcandles within a five-foot radius of the entrance or exit. e. Single-, two-, three- and four-family residential uses shall have a maximum illumination level of three foot-candles at the driveway or walkway, but no more than 0.5 footcandle at any property line elsewhere on the site. f. Pedestrian walkways or bikeways shall have an illumination level ranging between a minimum of 0.5 footcandle and a maximum of 2.5 footcandles. g. Large open areas and the grounds of multifamily housing complexes shall have a minimum illumination level of 0.3 footcandle and a maximum level of two footcandles. h. Canopied areas, such as those found at drive-through facilities at banks, service stations, car washes, shall have a maximum illumination level of 20.0 footcandles with a maximum to minimum illumination level ratio of 2:1. Illumination levels outside the canopy area shall not exceed 5.0 foot-candles. i. Display areas at outdoor dealerships for new and used products, including, but not limited to, automobiles, trucks, motorcycles and boats, shall have a maximum illumination level of fifteen-foot-candles for any row or tier of display that is adjacent to an external road or street, and a maximum level of 10 footcandles for all other rows or tiers of display. Entrances and exits shall not exceed 10 footcandles. j. Illumination levels for outdoor recreational facilities, such as, but not limited to, football fields, soccer fields, baseball fields, or tennis courts, shall be consistent with best practices from the Illumination Engineering Society of North America (IESNA) based on the type of facility, number of potential spectators, and overall surroundings, but shall comply with the illumination limits at property lines established above in this section 41:16-6-2.a. k. For all other outdoor spaces, the minimum illumination standard shall be 0.5 footcandle. Such illumination shall be controlled by motion sensor lighting. l. For covered parking areas or enclosed parking garages, a minimum lighting level of 2.0 footcandles shall be maintained. No lighting shall produce glare outside the structure. 3. The spacing between poles illuminating large open areas including, but not limited to, surface parking areas or lots, parks, or the grounds of multi-family housing complexes shall be no closer than 2 1/2 times the pole height. Light poles must be positioned to enable walkways to comply with local, Federal, or State disabled persons' access legislation. 4. Architectural Lighting. a. Fixtures used to accent architectural features, materials, colors, style of buildings or art shall be located, aimed and shielded so that light is directed only on those features. b. Such fixtures shall be aimed or shielded so as to minimize light spill into the sky. Such fixtures shall not generate excessive light levels, cause glare, or direct light beyond the facade onto neighboring property, streets or the night sky. Lighting shall not change colors or strobe. 5. Height Standards. a. Freestanding Lights. i. For residential uses, the maximum height of freestanding lights shall not exceed the height of the principal building or 15 feet, whichever is less. ii. For commercial and mixed-use uses, the maximum height of freestanding lights shall not exceed the height of the principal building or 20 feet, whichever is less. iii. For industrial uses, the maximum height of freestanding lights shall not exceed the height of the principal building or 30 feet, whichever is less. b. Mounting Heights. The mounting height of any building-mounted light source shall be the lowest height possible to achieve appropriate illumination, but in no case shall the mounting height exceed 20 feet above grade.

[Adopted 11-1-2023 by Ord. No. 6PSF-E, 11-01-2023 ]

Ask a question about Newark law

Corpus searches the Newark sections it holds and shows the ones that match, with their citations. Free, no sign-in.