13.09.050 - Standard design requirements.
A. Standard Requirements—Gravity Grease Interceptors. 1. Each facility is solely responsible for the cost of the grease interceptor installation, inspection, cleaning, and maintenance. 2. Gravity grease interceptor sizing and installation shall conform to the requirements contained in the current edition of the New Jersey Plumbing Sub-code or other criteria as determined on a case-by-case basis based upon review or relevant information, including, but not limited to grease interceptor performance, waste stream characteristics, facility location, maintenance needs, and/or inspection needs. Supporting sizing calculations shall be submitted to the city. 3. Gravity grease interceptors shall be designed by a professional engineer licensed in the State of New Jersey using standard engineering principles for sedimentation and flotation in gravity interceptors. The grease interceptor shall have a minimum of two compartments with fittings designed for grease retention. 4. Gravity grease interceptors shall be installed at an outdoor location where it is easily accessible for sample collection, inspection, and cleaning and removal of retained grease. The grease interceptor may not be installed inside a building and the location must meet the approval of the city. 5. Gravity grease interceptors shall be in the lateral line between all fixtures which may introduce grease into the sanitary sewer and the connection to the public sewer system. Such fixtures shall include but not be limited to sinks, dishwashers, floor drains for food preparation and storage area, mop sinks, and any other fixture which is determined to be a potential source of grease. 6. Gravity grease interceptors must be vented. 7. Gravity grease interceptors shall be equipped with a sampling port at the outlet of the interceptor. Inspection tees and manholes must enable the city to monitor and test the discharge for compliance with utility requirements or to allow monitoring and testing in accordance with the rules and regulations of other federal, state, or local agency having governmental or contractual jurisdiction within the utility service area. 8. Access manholes, a minimum diameter of twenty-four (24) inches, shall be provided over each chamber and sanitary tee. The access manholes shall extend at least to the finished grade and be designed to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, cleaning and removal of retained grease and sample collection. Riser maximum shall not exceed sixteen (16) inches. 9. Sanitary wastes shall not be introduced into the gravity grease interceptor. B. Standard Requirements—Hydromechanical Grease Interceptor. 1. Each facility is solely responsible for the cost of the HGI installation, inspection, cleaning and maintenance. 2. HGI sizing and installation shall conform to the requirements contained in the current edition of the New Jersey Plumbing Sub-code or other criteria as determined on a case-by-case basis based on review or relevant information, including, but not limited to grease trap performance, waste stream characteristics, facility location, maintenance needs, and/or inspection needs. Supporting sizing calculations shall be submitted to the city. 3. HGIs shall be designed by a professional engineer licensed in the State of New Jersey using standard engineering principles. Complete plumbing plans and isometric or riser diagrams are required at time of plan check submittal. The plans must be stamped by the professional engineer of record. 4. HGIs shall be installed at a location where it is easily accessible for sample collection, inspection, and cleaning and removal or retained grease. 5. The HGI shall be equipped with a device to control the rate of flow through the unit. The rate of flow shall not exceed the manufacturer's rated capacity recommended in gallons per minute for the unit. 6. Sanitary wastes cannot be introduced into the HGI. 7. Grease traps shall be installed at a minimum distance of ten (10) feet. from sinks and dishwashers to allow for adequate cooling of the wastewater. Water temperatures must be less than one hundred twenty (120) degrees prior to entering grease trap to avoid pass through. C. Best Management Practices. 1. Kitchen best management practices shall be implemented to minimize the discharge of FOG to the public sewer system and prevent non-stormwater discharges from entering the stormwater sewer system (as applicable): a. Drain screens shall be installed on all drainage pipes in food preparation areas. b. All waste cooking oil shall be collected and stored properly in fats, oil and grease receptacles such as drums or tallow bins. Such containers shall be maintained properly to ensure they do not leak. c. Licensed waste haulers or an approved recycling facility must be used to dispose of waste cooking oil. d. Waste fat and grease storage bins or waste oil drums shall be kept cleaned and covered. Lids on waste storage bins and drums shall be kept securely closed and the areas around these containers shall be kept clean. D. All food waste shall be disposed of directly in garbage or compost collection bins, and not sinks. Bagging food waste that has the potential to leak in trash containers is recommended. Scrape or dry wipe pots, pans, dishware, and work areas before washing to remove grease. Wash only in a sink connected to a grease control device. E. Filters and other exhaust hood equipment shall be cleaned as frequently as necessary to maintain good operating condition. The wastewater generated from cleaning shall be disposed of properly and cleaned in sinks connected to a grease removal device. Outdoor steam cleaning of exhaust filters in uncontained areas is strictly prohibited. F. Informational signs on best management practices and waste minimization practices in food preparation and dishwashing areas shall be always posted. G. The wastewater generated from floor mat and kitchen appliance washing operations must be disposed of to a sink with a grease control device. Cleaning kitchen equipment in uncontained areas that drain to a sewer is prohibited. H. Dry methods including rags and absorbents such as sawdust or kitty litter shall be used to clean up oil and grease spills. I. Training shall be conducted for all new kitchen staff every six months. Training shall be documented with employee signatures retained indicating employee attendance. Training records shall be made available for review at any reasonable time to the city local health department. J. Best management practices (BMPs) shall be documented at maintained at the FSE. Documentation includes: Spill events, floor mat/equipment cleaning scheduling, inspections of FOG containers and any other relevant information related to BMPs.
(Ord. No. O-042604, § I, 4-15-26)
Ask a question about New Brunswick law
Corpus searches the New Brunswick sections it holds and shows the ones that match, with their citations. Free, no sign-in.