For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 37-305 — Acceptance of improvements

Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 37-305

Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/212487b3-a382-4009-aa0d-e46721bbc2f4

Sec. 37-305. - Acceptance of improvements.

A. The subdivider may request the city to approve and accept the roadway, utility, and drainage improvements. For preliminary acceptance of utility improvements, and prior to connection to the city's utility system, the subdivider shall be required to submit utility blueline drawings for review and approval by city engineers. Such drawings shall be submitted to the utilities department projects administrator. B. Upon completion of the development, the subdivider may make a written request to the subdivision administrator for final acceptance of all subdivision improvements. Along with the written request, the city shall require the submission of one set of Mylar record drawings (as-builts), a computer-aided drawing file on a 3.5-inch computer diskette or recordable CD, or other format accepted by the city, and a detailed material listing. The city shall inspect said improvements to determine whether the infrastructure is acceptable and whether it conforms to the approved final plat and construction drawings. The computer-aided drawing file on computer diskette or CD may be waived by the development review committee. Granting a waiver shall not serve as a convenience to the applicant, but the waiver shall be the minimum necessary for relief due to some demonstrable hardship, and shall be granted only in cases where reasonable alternative means are not available to resolve the issue(s). C. The computer-aided drawing file to be submitted shall be labeled with the contractor's name, the engineer's name, the subdivision name, the subdivision location, and the final inspection date. The computer-aided drawing file shall be the file used to generate the final record drawings (hard copy). The computer-aided drawing file shall depict the final Mylar as-builts with the rights-of-way and the subdivision tied to the state plane coordinates. The computer file drawing shall be in AutoCAD Version 11 or later, or in a similar 100 percent compatible and transferable file. Prior to submittal of the digital record drawings, the project engineer shall enter into a digital file agreement with the city. The purpose of the digital file agreement is to protect the project engineer from liability in the event that the drawings become altered in any manner not approved by the city and the project engineer. D. Said Mylar drawings shall be signed and sealed by a registered engineer of the state. The Mylar drawings made from the design drawings based on the contractors' as-builts and the computer-aided drawing file shall provide the following information for city review: 1. Grade changes. Reflect all changes in grading from the approved plan and profile sheets, including but not limited to curb elevations, property line elevations, drop inlets, curb return elevations, tops of manholes, and inverts. 2. Street alignment changes. Designate any alignment change within a street right-of-way that deviates from that shown on the approved plan and the profile sheets. 3. Detail sheet changes. Reflect any change in street cross sections, retaining walls or other general details that have been altered from the approved construction drawings. 4. Utility changes. Designate all utility changes that deviate from the approved plan and profile sheets. E. Additionally, a detailed material listing shall be required. The materials listing must be a tabular listing that includes, wherever appropriate, mains (sewer mains must include depth), valves, manholes, fire hydrants, number of service lines and number of drainage inlets. These materials must be represented in the listing by the standard measure or by the unit installed, e.g., linear foot, number of each. The listing must be separated by utility function for potable water, wastewater, storm drainage and gas. The listing must include: 1. Developer's name; 2. Subdivision name and location; 3. Date of final inspection; 4. Quantity and unit of materials installed (e.g., 250 linear feet, eight each); 5. Material description, including size or dimensions (e.g., 4-inch PVC main). F. The subdivision administrator, upon receipt of a written report of recommendation for acceptance and from: 1. The public works director that all improvements have been installed in accordance with the plans, as approved, and are in conformity with the requirements of this chapter; and 2. The utilities director that all utility improvements have been installed in accordance with the plans, as approved, and that they are in conformance with the requirements of this chapter; May formally accept said public improvements for city maintenance. The subdivision administrator will notify the subdivider within ten business days after his/her request as to whether the improvements will be accepted for city maintenance. The subdivision will be accepted only with the concurrence of the subdivision administrator, public works department director and the utilities department director. Upon acceptance, the subdivider shall guarantee improvements for one year.

(Ord. No. 2686, § I(Exh. A), 8-5-13)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.