§ 38-45 — AdM—Avenida de Mesilla Gateway overlay zone district
Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 38-45
Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/73a49f9e-ffed-4d99-bc75-5d525c0a6401
Sec. 38-45. - AdM—Avenida de Mesilla Gateway overlay zone district.
A. Purpose. The purpose of the Avenida de Mesilla Gateway overlay zone district is to implement land use and urban design policies as established in the Avenida de Mesilla Gateway plan. Specifically, the purpose of this zone is to utilize special provisions to provide guidance in future decisions regarding zoning, land use, urban design, and transportation. The overall intent of the district is to create a gateway which promotes an aesthetically pleasing yet functional environment in which citizens from both the city and the Town of Mesilla can interact socially, where the business community can exist in a commercially viable environment, and where both endeavors can co-exist with little or no conflict with one another. B. Delineation of overlay zone district. The Avenida de Mesilla Gateway overlay zone district shall include all properties in their entirety, regardless of any future partitions thereof, having frontage directly on Avenida de Mesilla, from Valley Drive, west to the city limits. The applicable properties affected by this overlay zone district are indicated by the district map in this section. This map reflects all applicable parcels as of March 20, 2000. C. Permitted uses and development standards. There shall be no development or alteration of the lands, uses, or structures within this overlay zone district except as provided for by this section of this Code from the date of its enactment, and other sections of this Code and other codes where applicable. 1. Permitted uses—No conditions. Unless expressly prohibited by this section or modified by conditions, all permitted uses and special uses will adhere to the underlying zoning of the property. 2. Permitted uses—With conditions. The following uses are permitted in accordance with stated provisions. The following list is intended to supplement any permitted use, with or without conditions. a. Automobile parking lot/parking garage. Permitted only when all applicable urban design requirements are followed. b. Bus terminal. Permitted only when all applicable urban design requirements are followed. No storage of buses on-site and no repair facilities permitted. c. Commercial or trade school (totally enclosed). Permitted only when related activities occur within an enclosed building and when there are no materials, equipment, or machinery used in the conduct of said activity stored outside. The use shall not pose any adverse impacts to adjacent properties due to noise, odor, dust, or vibration. [image omitted; see the official code] d. Cottage industry. Such use shall meet the following requirements: 1) Permitted only when such use occurs within a totally enclosed building on the premises where the primary use (retail/service) is conducted; 2) The processing of goods shall be clearly accessory to the primary use (retail or service) where a maximum of 49 percent of the total business floor area, not to exceed 3,000 square feet, shall be used in the conduct of the cottage industry. 3) The use shall not pose any adverse impacts to adjacent properties due to noise, odor, dust, or vibration. 4) No more than three separate cottage industries may operate on any one parcel. e. Dance/music academy. Permitted only when used for instruction and/or the conduct of activities related to the performing arts. f. Dwellings as an accessory use for a proprietor, resident watchman, or caretaker. Permitted only when said dwelling meets all applicable urban design criteria and is constructed on-site. g. Engraving shop. All related activity shall be completely enclosed within the building used for the primary use and there shall be no outside storage of parts, inventory, or related materials whether temporary or permanent. h. Food/beverage production or packaging. Such use shall meet the following requirements: 1) Permitted only when such use occurs within the same building as the primary use; 2) The use must remain secondary to the primary use (retail or service). 3) In no event shall the square footage for any production/assembly process associated with the commercial activity exceed 49 percent of the total business floor area (not to exceed 3,000 square feet). 4) All ancillary activity (processing) uses shall conform to the following: a) Shall be conducted in a manner which serves to enhance the general retail and/or service atmosphere. b) Examples of establishments which may conduct this ancillary activity include cafes/restaurants, taverns, and other like uses involving food/beverage related products (human consumption) within applicable zoning districts. c) The ancillary activity shall not pose any adverse impacts to adjacent properties due to noise, odor, dust, or vibration. i. Gasoline station. Permitted only when vehicle repair activities are not associated with the use. j. Temporary uses. Temporary uses shall follow provisions as outlined in section 38-50; except as further stated. For purposes of the Avenida de Mesilla Gateway overlay district, temporary uses shall be limited to: 1) Christmas tree stands. Sales of Christmas trees shall not occur before November 15 or after December 31. These uses shall be permitted only in C-2, C-3, M1/M2 and M-3 underlying zoning districts. 2) Yard, garage or rummage sales. These types of uses shall be conducted for no more than four days, three times at one location in a calendar year. No permits are required for these uses and they must be conducted from an individual's dwelling. The conduct of these activities from a business or other property not used primarily for residential purposes is prohibited. This use is permitted in all applicable underlying zones. 3) Community wide event. Temporary uses at the time of a community wide event are permitted to begin one week (seven calendar days) before the beginning of the community wide event and shall end three calendar days from the last day of the community wide event. For purposes of the Gateway, a community wide event is defined as a celebration or event that primarily promotes the community as a whole and not a single business or group of businesses per se. The activities may or may not involve retail special sales related to the specific celebration. Furthermore, the celebration/event must be sponsored by either local government(s) or not-for-profit organizations. These events may involve the use of tents and other temporary structures. Examples of community wide events include, but are not limited to The Mesilla Valley Hot Air Balloon Rally, custom car shows, public expositions, etc. These uses are permitted in R-4, O-2, C-2, C-3, M1/M2 and M-3 zones. (Also see Municipal Code Chapter 18, Article IV.) 3. Prohibited uses. The following identifies those uses which are prohibited regardless of the underlying zoning district: Acid manufacture Adult amusement establishment Adult bookstore/video store Airport and heliport Amusement park or enterprise (temporary or permanent) Assembly of electronic or mechanical parts and equipment Auto, truck, camper, and recreational vehicle sales and service Automotive washing establishment Boat sales, service, and repair Body shop Bus garage/storage/repair Cement, lime, gypsum or plaster manufacturing or mixing Cemetery Cigarette and cigar stand (temporary or permanent) Clothing manufacturer Construction or contractor's yard (permanent) Dance hall Drive-in theater Dyeing establishment Electrical shop (contractor) Explosive manufacture or storage Fabrication shop Fat rendering Fertilizer manufacture/processing Flea market Firewood sales Fraternity house Freight house or truck terminal Frozen food locker Glue manufacture Heavy equipment sales and service Junk yards, salvage, or wrecking yards Kennel (commercial) Lumber yard (outside storage) Manufacturing of consumer goods such as: appliances, batteries, garments, etc. Metal work and machine shop Microwave radio relay structure Mini storage units Mobile/manufactured homes Mobile home park Mobile home sales and service Mobile home subdivision Monopole Motorcycle sales and service Open or exterior storage and display of merchandise and/or materials (except when products offered and displayed on the premises are either: 1) Grown on or off the premises; or 2) Home-crafted, hand-crafted, or hand-assembled by crafts-persons on or off the premises. Examples of acceptable products include, but may not be limited to, nursery stock, fruits and vegetables, leather crafts, paintings, woodwork, metalcraft, ceramics, sculpture, basketry, weaving and yarn work. Items shall typically be considered "non-durable commodities" which serve to foster the cultural and historical characteristics of the Mesilla Valley region. Examples of unacceptable products include, but may not be limited to, motorized vehicles, or equipment, bicycles, trailers, clothes washers, cloth dryers, fabricated storage sheds, playhouses, animal shelters, and goods commercially produced through mechanized means. Structures/walls/fences used to enclose and/or protect the display of goods shall be compatible to the architectural design of the primary building located on site. When no architectural style is defined within these regulations pre-exist on the property, one of the required styles shall be used for purposes herein stated.) Packaging of cosmetics, pharmaceuticals, toiletries Paint shop (spraying/mixing—nonretail sales) Petroleum refining Plumbing and heating shop (contractor) Public utility installation, substation, and water well Racetrack Radio and TV broadcasting Raw materials manufacturing, processing, and extraction Recreational vehicle park Recycling/purchase center Sign construction and sales (exclusive of signs created pursuant to a cottage industry) Smelting of ores Sorority house Stables (commercial) Stadium: Baseball, football, soccer, track Stock yards or slaughter of animals Storage of wrecked or dismantled vehicles and parts (primary or accessory use) Street vendors Television and radio towers and all other free standing towers (public or private) Temporary uses—Pursuant to temporary use permits (except those specifically identified elsewhere in this section.) Tire sales and service Warehouse/storage/distribution center Welding shop (primary or accessory use) Wrecker services 4. Development standards. The following development standards shall apply to all fronting properties along the Gateway: Minimum lot area/size/dimensions: Refer to underlying zone development standards. Minimum setback provisions: Refer to underlying zone development standards. Maximum building height: 40 feet. Not to contain no more than two stories. Pertains to all allowed uses within underlying zoning districts. D. Nonconforming uses. The following nonconforming use provisions shall apply to properties within the Gateway. Provisions pursuant to section 38-45.D.2.d below which allow increases in floor, building, or lot square footage shall not nullify minimum compliance requirements (i.e. parking and landscaping) established elsewhere in this Code or in other companion codes. 1. Permitted uses with nonconforming urban design features. a. When nonconforming urban design features involving parking, landscaping, lighting, and fencing/walls are located on properties within the Avenida de Mesilla Gateway overlay zone district, these features shall be brought into compliance with Gateway standards when: 1) The property remains vacant for a period of one continuous year or greater; or 2) Any one-time or cumulative increase of ten percent to the gross square footage of building area occurs; or 3) Any exterior remodel, renovation, or alteration occurs to the building. This provision shall not nullify allowances as identified in item 1.a.2); or 4) A change in use occurs on the property which results in the alteration of the uses intensity (i.e. low volume to high volume business activity) or orientation (i.e. service to retail activity). b. When the architectural characteristics of the building are nonconforming, the architecture shall be brought into compliance with current standards when: 1) The property remains vacant for a period of one continuous year or greater; or 2) Any one-time or cumulative increase of 30 percent is made to the gross square footage of building area; or 3) Any exterior remodel, renovation, or alteration occurs to the building. This provision shall not nullify allowances as identified in item 1.b.2). c. When a sign on the property is nonconforming, it shall be brought into conformance with current standards when: 1) The property remains vacant for a period of one continuous year or greater; or 2) A change in use occurs on the property which results in altering the uses intensity (i.e. low volume to high volume business activity) or orientation (i.e. service to retail activity). 2. Prohibited uses with nonconforming urban design features. a. Commercial uses that existed within the Gateway prior to plan/ordinance adoption and which are specifically identified as a prohibited use, may be allowed to expand or enlarge (either one-time or cumulative increase) provided that: b. Said increase is no greater than 49 percent of the gross square footage of the lot, if said increase involves the incorporation of additional land area; or c. Said increase is no greater than 49 percent of the gross square footage of building area, if said increase is through the addition of building floor area; and d. All nonconforming urban design features are brought into compliance with Gateway standards when the lot area or building floor area has increased by 25 percent. e. In the event that a prohibited use is discontinued, removed, or otherwise ceases to exist on the subject parcel for any duration of time, said use shall lose its nonconforming status. Thereafter, any subsequent use and nonconforming urban design feature shall be made to conform with all applicable development requirements. For purposes herein stated, a change in ownership of a nonconforming use shall not constitute a loss of nonconforming status. Additionally, maintenance of an official business registration in the absence of the corresponding bonafide use of the property, shall not be considered a continuation of a land use and may at the Community Development Directors or his/her designees discretion, trigger compliance requirements. 3. For purposes of this section, exterior remodel, renovation, or alteration shall be defined as: any change or rearrangement in the supporting members of an existing building, such as bearing walls, columns, beams, girders, as well as any change in roof lines, or any enlargement to or diminution of a building or structure, whether horizontally or vertically. Normal maintenance activities as verified by the city's building official or his/her designee are exempt from this provision. E. Urban design standards. To insure quality property development and renovation, the following requirements regulating urban design are established in this overlay zone district. 1. Architectural design. a. Purpose. Architectural design standards are established for this district in order to create uniformity of physical design consistent with the district's unique architectural characteristics. See appendix I for a visual guide of the architectural design portion of this ordinance. 1) Architectural design standards are established as follows: For properties along the Gateway, Pueblo, Spanish Colonial, Territorial, Mission, and other southwest vernacular architectural styles shall be required. The Pueblo, Spanish Colonial, Territorial, and Mission architectural styles represent those which are strongly encouraged within the Gateway. For information regarding other allowable styles, please refer to New Mexico Historic Building Inventory Manual, section VI, Introduction To New Mexico Architectural Styles, which is available in the city planning office. a) Pueblo. (1) Required facade features. (a) Walls shall be surfaced with a smooth stucco surfacing and shall incorporate soft rounded corners or buttressed corners in order to emphasize structural massing. (b) Parapet walls above the roof line shall be used in the design and shall have rounded edges and variations in height. Variations in height of parapet walls are recommended. (c) The use of bell coates (espadañas) or other design strategies which simply vary the heights of the facade shall be incorporated in large scale (business center or apartment complex) commercial or residential buildings. (d) Structures which are more than one story in height shall have the top story setback further from the front property line than the first story. (2) Roofs. (a) Required roof features. Roofs shall generally lie flat except that sloping of the surface will be allowed to facilitate the shedding of moisture. (b) Recommended roof features. Canales made of clay or treated wood shall be incorporated along appropriate areas of the roof and facade to aid in the removal of the surface moisture. (3) Required color features. Stuccoed walls and applied ornamentation shall be of a desert or earth tone. (4) Ornamentation. (a) Required ornamentation features. (i) Although the pueblo architectural style is generally limited in ornamentation, the use of exposed/treated wood lintels above windows and entryways and wood vigas shall be required. (ii) Vigas, applied as decoration, shall be placed along the exterior wall in a single orientation (i.e. north/south or east/west) in order to avoid the appearance of crossed or misplaced supports (buildings of more complicated design may be allowed multi-directional placement). (iii) Vertical supports for portales/loggias, if used in the design, shall consist of round wood columns with corbel bracketed capitals. (b) Recommended ornamentation features. (i) Application of exposed/treated wood lintels above windows and entryways and wood vigas may be used in their true structural form or may be applied simply as decoration. (ii) The use of portales/loggias are strongly encouraged but are not required elements. (iii) If chimneys are incorporated as a design feature, all components shall be appropriately constructed and detailed in a manner consistent with the rest of the structure. b) Spanish Colonial. (1) Facade. (a) Required facade features. (i) Walls shall be surfaced with a smooth stucco surfacing. (ii) Structures which are more than one story in height shall have the top story setback further from the front property line than the first story. (b) Recommended facade features. Walls are encouraged to include a belt mold which encircles the building along the top of the facade. (2) Roofs. (a) Required roof features. (i) Roofs shall be pitched using a 4 in 12 to 5 in 12 pitch. (ii) Roofs over balconies and other such features may have pitches of 2 in 12 or 3 in 12. (iii) Roofs shall be surfaced with clay barrel tiles or a material giving a similar appearance. (b) Recommended roof features. (i) Roofs are encouraged to have clipped eaves, generally flush with the wall. (ii) When overhangs are created, exposed and treated timbers should be used. (3) Color. (a) Required color features. (i) Stuccoed walls shall be white or contain otherwise light desert colors. (ii) If color accents are used, they shall not be of a stark contrast to the primary color of the wall. (iii) Roof color shall contain red tones. (b) Recommended color features. Color accents are a recommended feature of the Spanish Colonial style. (4) Ornamentation. (a) Required ornamentation features. (i) Windows shall be of a divided light variety and shall be recessed or otherwise defined and accentuated with molded surroundings. (ii) Walls for courtyard and patios, if used, shall be thick and/or otherwise appear massive. (iii) If shade structures are used, they shall have strong timber accents such as beams or joists. (b) Recommended ornamentation features. (i) Limited arches should be used in the overall design of the structure. (ii) Arches serving primary entryways are typical and are encouraged. (iii) All doors should be constructed of or give the appearance of heavy carved wood. (iv) Courtyards and patio designs incorporated into the building design are strongly encouraged. (v) Shade structures are also encouraged. (vi) If chimneys are incorporated as a design feature, all components shall be appropriately constructed and detailed in a manner consistent with the rest of the structure. c) Territorial. (1) Facade. (a) Required facade features. (i) Walls shall be surfaced with either a smooth stucco or brick. If brick is used, the brick must be antiqued or otherwise treated to give the appearance of a weathered and aged brick. (ii) Parapet walls above the roof line shall be used in the design and shall be capped with brickwork, masonry, or wood unless a folk territorial design is used, in which case, no parapet shall be used. (iii) Structures which are more than one story in height shall have the top story setback further from the front property line than the first story. (b) Recommended facade features. (i) Overall building form should be clean and simple in appearance. (ii) Structures should have facades of varying heights. (2) Roofs. (a) Required roof features. (i) Roofs shall generally lie flat except that sloping of the surface will be allowed to facilitate the shedding of moisture. (ii) Folk territorial designs shall have pitched gable roofs surfaced with tin or corrugated sheet metal which has been factory painted/treated in a manner which eliminates its reflective properties yet contributes to the design characteristics of the selected architecture. (b) Recommended roof features. Dormer windows are not required in folk territorial designs, but are strongly encouraged. (3) Color. (a) Required color features. (i) Stuccoed walls shall have earth tones such as tan, sand, and beige. (ii) Brick facades shall consist of muted colors such as red brick which has been "antiqued." (b) Recommended color features. Trim materials shall have light or neutral colors which contrast to primary surface colors. (4) Ornamentation. (a) Required ornamentation features. (i) In designs which incorporate parapets, the cornice shall be detailed with decorative brick or wood and contain dentil ornamentation. (ii) Window and door openings shall be set flush with the wall and shall have trim treatments of brick or wood surrounding the fenestration. (iii) The use of pediments (wood trim treatment) above doors and windows is required. (iv) Windows shall be of a divided light variety. (v) Ornamentation treatments for porches or porticos, if used, shall be similar to those incorporated on the primary structure (wood cornice and dentil treatments are typical) and shall be supported by wood columns. (b) Recommended ornamentation features. (i) Canales should be square or rectangular in shape and be constructed of a natural material such as wood, or have surface treatment which is consistent with the primary structure. (ii) If window shutters are used, they shall be paneled. (iii) Doors should be constructed of wood or treated to give the appearance of wood and should also be paneled. (iv) Designs incorporating porches or porticos along the facade are strongly encouraged. (v) Separate shade structures or treatments over balconies are not required but, if used, shall incorporate exposed timber in the design. (vi) If garden walls are used, they shall be surfaced with stucco and shall have a brick cap similar in treatment to that used for the primary building walls. (vii) Chimneys are not required but, if incorporated as a design feature, all components shall be appropriately constructed or otherwise detailed in a manner consistent with the rest of the structure. d) Mission. (1) Facade. (a) Required facade features. (i) Walls shall be surfaced with a smooth stucco finish and maintain clean edges or corners. (ii) Walls shall give the appearance of mass through their construction. (iii) Larger structures (i.e. business center, hotel etc.) which contain two stories shall: (aa) Create two distinct levels, (bb) Feature an arched portal feature along the first level, (cc) Incorporate a vertical element such as an espandana or bell coate in the design, (dd) The portal shall characteristically contain curvilinear openings or archways to emphasize the portal and assist in defining the two levels, and (ee) The second story shall be set back further from the front property line than the first story. (ff) All facades regardless of building size shall incorporate arched entryways in the design. (gg) Arched window openings or detailing is strongly encouraged for all such openings and shall be required for windows which figure prominently in the facade design. (hh) Facades shall also incorporate curvilinear parapets projecting above gabled rooftops. (b) Recommended facade features. (i) Smaller structures used for single uses or a small number of uses will comply with the following: (aa) May incorporate similar design features as what is required of the larger structures; and (bb) Greater design latitude shall be afforded to smaller structures in order to ensure that scale and mass do not overwhelm the overall appearance. (2) Roofs. (a) Required roof features. (i) Roofs shall be pitched in a gable fashion and shall be surfaced with a red colored tile. (ii) Emphasis to the roof detailing shall be provided through the use of curvilinear parapets. (b) Recommended roof features. Projecting eaves, if utilized, shall be accentuated with exposed rafters. (3) Required color features. (a) Stuccoed walls shall have light or neutral tones. (b) Roof tiles shall have a red tone. (4) Ornamentation. (a) Required ornamentation features. Curvilinear parapets shall be required. (b) Recommended ornamentation features. (i) Any projecting eaves shall be required to be accentuated by exposed rafters. (ii) Detailing which emphasizes rounded or curved openings such as windows or portal entry arches is encouraged. b. Wall surfacing. 1) For all other architectural styles not outlined above, stucco or brick shall be the material used for all exterior wall surfacing (exclusive of trim details, etc.). 2) Freestanding walls/fences if used as a design feature shall be constructed of adobe or cinder block layered with stucco, or wrought iron or any combination thereof except that all wall treatments shall be consistent with the architectural style used for the building(s). 3) Slump block shall not be used as a finish surface for any facade or freestanding wall. 4) No chain link fencing shall be permitted unless used for temporary purposes related to construction which occurs on site. c. Multiple story structures. 1) Two story structures, regardless of architectural type, shall have their stories terraced or staggered so as to provide a transitioning of structural bulk and scale. 2) Special design features such as espadañas (bell coates) are exempt from this provision. 3) Portals incorporated in the design and placed along the facade may be considered an acceptable transition mechanism, as identified in c.1), above. d. Accessory structures. 1) All accessory structures such as storage buildings, work shops, and structures used to enhance indoor/outdoor space (i.e. pergolas or other shade devices within courtyards etc.) shall be constructed and otherwise detailed in a manner consistent with the architecture of the primary building. e. Sensitive building design 1) All building facades shall become an integral part of the overall design and reflect the architectural style chosen. 2) When necessary, the use of landscaping shall be required to break up building facades which by their design may have long, continuous surfaces with limited fenestrations or other openings. 2. Landscaping. a. Purpose. The landscaping standards for new development, and the encouragement of landscaping for existing property along the Gateway, are established to represent the agricultural theme prevalent within the Gateway area and the Mesilla Valley in general. Landscaping will also screen/buffer parking lots from the right-of-way and soften their overall impact. 1) Definitions. a) Landscape shall be defined as the following per 1000 square feet of landscape area required: (1) Two two-inch caliper trees as measured six inches above soil level and which reach a minimum height of 25 feet at maturity as referenced in The New Western Garden Book (most recent edition), and (2) Fifteen five-gallon shrubs, and (3) A choice of either five one-gallon shrubs or 50 square feet of ground cover for every 500 square feet of lot area excluding building area and parking lot area in addition to five one-gallon shrubs. 2) Landscaping for new development along the Gateway shall be provided to cover 15 percent of the lot area exclusive of building area. 3) All landscaping shall be provided on site. 4) Of the total area to be landscaped, fifty percent (50 percent) shall be located within the front setback of the property. Of this percentage, one-half (2) shall be located between the front property line and the parking lot. Note: Front setback of the property shall be defined as: the area between the back of sidewalk and the property's principal structure. 5) A minimum of 25 percent of the total required landscape area and 25 percent of required plant material shall be located along the rear and sides of any principal and/or ancillary building. 6) The remaining 25 percent of the required landscaping shall be incorporated in areas adjacent to service areas (loading docks/bays, dumpsters, etc.), building/utility equipment, and within ponding areas as a means of providing a screen or buffer to these potentially harsh/contrasting development features. 7) In addition to the 15 percent required landscaping percentage, all development exclusive of single-family and duplex properties shall be required to plant trees within the parking areas for shade and visual relief. a) Trees located within the parking area shall maintain a minimum height of six feet before the first lateral branch and shall reach a minimum canopy diameter, at maturity, of 20 feet. b) All parking areas shall have a minimum requirement of one 24-inch box tree per every ten parking spaces within the parking lot. Trees shall be located in an island and/or planters which will protect tree trunks from cars. (1) Addition of a barrier such as a curb, wheel stop, or bollard shall be required to be used as protection. (2) Islands shall be a minimum of three feet wide. (3) Islands shall be located so as to relieve the large expanses of paving and to provide shade and contribute to orderly multi-modal circulation. c) Trees should be planted along the edge and/or between parking stalls in planter areas which have a minimum area of 49 square feet, dimensional requirements as provided in Appendix I at the end of this section, and a raised border of at least four inches in height. d) Where a landscape border or similar feature abuts parking stalls, trees within those areas may count toward the parking area tree requirement, provided: (1) The trees are planted within ten feet of the parking stall area perimeter; and (2) The number of parking area trees required pursuant to these regulations is not reduced by more than half as a result of this condition's implementation; and (3) A minimum of one tree is provided within the parking area. 8) Ground cover material consisting of bark, pecan shell, decorative stone, or river rock shall be used on any ground surface which would otherwise be exposed. Excessively large expanses (greater than 500 square feet) of ground covered landscape areas shall be avoided unless vegetation and variety in ground cover textures are incorporated to help mitigate incompatible scale concerns. 9) The property owner shall be responsible for maintenance of all plantings and for a sufficient irrigation system to water all plant material, but should also conserve water, as per the city design standards. a) In the event the required maintenance is not being provided 20 days after notice from the city, the property owner shall be subject to a fine as per the Municipal Code. b) Each day of such and infraction shall be deemed a separate offense. 3. Site design elements. a. Buffering—Purpose. Visual screens/buffers are established to soften the harsh look of parking lots and other physical features from the right-of-way and to ease their overall impact. Through the use of required landscaping, landscaping elements, garden walls, berms, hedges, and/or other landscape features, this separation will exist. The following provisions shall be considered when creating this separation: Buffer strip. 1) A minimum ten-foot wide buffer strip shall be required between parking lots and the property line which is most parallel with Avenida de Mesilla. 2) Buffers shall have a minimum vertical height of two feet and a maximum vertical height of three feet, as measured from top of buffer element to top of curb. All clear site triangle provisions shall apply as stated in article III, definitions. 3) Berms. a) Berms shall have a maximum design slope of one foot of rise for every five feet of distance (grass) or one foot rise for every three feet of distance (ground cover). b) Walls, if used in conjunction with berms or as the sole buffering mechanism, shall be placed at the farthest location away from the property line, closest to the parking area. Head-in-parking adjacent to walls must use wheel stops or be offset at least 2.5 feet from the curb. c) Design considerations shall be implemented to control erosion where berms abut sidewalks. 4) All landscaping used within the buffer strip may count toward fulfilling the landscaping requirements pursuant to applicable provisions. 5) Aesthetically incompatible service areas and building mechanical/utility equipment. a) Dumpsters. (1) Dumpster locations shall be surrounded by a wall having a minimum height of at least one foot above the refuse container and which is compatible with the architectural character of the development in material and location. (2) Landscaping shall also be placed in close proximity to the dumpster so as to cause a more appropriate transition or blending of physical features. b) Freestanding building mechanical/utility equipment. (1) This equipment shall be screened from view using landscaping or walls in a manner that conceals the equipment and remains consistent with the landscape/ architectural character of the project to which it pertains. (2) Equipment that is on the rooftop or otherwise attached to the building shall be screened from view through the use of building design elements such as parapets or similar strategies. (3) When the chosen architectural style selected does not lend itself to using these techniques, equipment shall be placed toward the rear of the building rooftop or facade and shall be painted with a color that most accurately matches the building element to which it is attached. 4. Sidewalks. Sidewalk installation requirements shall adhere to the city design standards and the city sidewalk ordinance requirements, except that: a. Future large scale (block lengths or greater) sidewalk reconstruction and new installation efforts shall require the matching of sidewalk surfacing consistent with that found along Avenida de Mesilla near the Avenida de Mesilla/Calle de El Paso intersection. b. Small scale (less than block length) installation of new lengths of sidewalk and small scale sidewalk reconstruction shall be examined on a case by case basis to see if surface matching is appropriate. c. Piecemeal surface matching should be avoided. 5. Signs. a. Purpose. The Avenida de Mesilla Gateway overlay zone district sign code shall be established for aesthetics, height, overall size, type and lighting considerations for signage consistent with the district's urban design standards. b. In determining applicable sign standards, chapter 36 shall apply, except as provided below: 1) Off-premise signs. No off-premise signs shall be allowed along the Gateway except for the following: a) Political signs that are no greater than 32 square feet in area and six feet in height. Signs shall be erected no sooner than 30 days before the election to which they pertain and shall be removed within seven days following same election. b) Off-premise sign displays regarding community events or holidays may be permitted, if approved by the city manager or designee. 2) Temporary signs/displays. Temporary signs/displays shall be limited to banners, pennants, streamers, balloons and real estate signs. a) Banners, pennants, streamers, and balloons shall be subject to applicable provisions identified within the city sign code pursuant to commercial promotional display (section 36-118) and residential promotional display (section 36-119). b) Real estate signs shall be no greater than 15 square feet in sign area. Sign height shall be no greater than six feet. When signs are greater than eight square feet in sign area, they shall be constructed entirely of wood and shall incorporate corporate logos, illustrations, or other graphics along with the text to create a more aesthetically pleasing sign display. Signs in excess of eight square feet shall utilize a combination of differing geometric shapes in the design of the sign face's outline or silhouette. 3) On-premise attached signs. a) Wall, window, and canopy signs shall be the only attached sign types allowed within the Gateway. b) The maximum total sign area shall be no greater than one square foot of signage per linear foot of street frontage along Avenida de Mesilla only. For a single business located on one or more lots, the total attached sign area shall not exceed 250 square feet. For a development involving business/shopping centers, the maximum total sign area shall be limited to that authorized by the sign area calculation using Avenida de Mesilla frontage. c) Except for canopy signs, there shall be no limit to the number of signs used provided that their cumulative square footage does not exceed the maximum allotment (see also, window sign design standards, on-premise point-of-sale and accessory use signs) allowed. d) No more than 20 percent of the window area shall be covered by a window sign. e) Canopy signs shall be placed on no more than two sides of the canopy. Sign(s) may either be attached to the canopy through the use of either channel letters (construction characteristics), or the sign(s) may be painted, imprinted, or stamped on the canopy face. Only one sign type may be used per canopy. Canopy signs shall not occupy more than 33 percent of the canopy side to which they are attached and shall be primarily used for corporate/business identification only and not advertising pre se. For purposes of these regulations, canopies shall be defined as provided in article III and shall not include portales, poticos, loggias, zagguans, miradors, and other similar architectural design features/elements customarily used in southwestern architectural vernacular. 4) On-premise freestanding signs. a) Ground signs shall be the only freestanding sign allowed within the Gateway. b) If two signs are allowed, the second sign may be of a design, size, and height permitted pursuant to the city's sign ordinance and shall be located toward the property line which is furthest from and most parallel to Avenida de Mesilla, at a distance from that line which shall not exceed 15 feet. All other applicable sign setbacks and related provisions shall apply for the sign. c) Ground signs located along Avenida de Mesilla shall be no larger than six feet in height and no greater than 32 square feet in sign area. d) Each ground sign shall maintain a ten-foot setback from front and side property lines. e) Wood shall be the predominant material used in the construction of the ground sign's copy. f) The illumination of the ground sign must not be positioned so as to interfere or visually impair passing motorists, bicyclists, or pedestrians. g) If the lighting standard is visible, it shall be decorative in its construction and shall be consistent with the architectural style of the property. h) Properties developed as business centers shall conform to the following: (1) One ground sign identifying the name of the center. (2) One directory ground sign will be allowed. (a) The directory ground sign shall be no greater than six feet in height. (b) The sign shall provide no more than four square feet of sign area for the identification of each tenant. (3) Overall sign area is dependent on the number of businesses within the business center. (4) All other provisions set forth in article VIII and this section regarding setbacks, construction materials, and illumination shall apply. (5) On-premise point-of-sale and accessory use signs. (a) These sign types shall follow all applicable provisions identified within the sign code. (b) For purposes of the Gateway, the square footage of these sign types shall be part of the total square footage allowed under the provisions for attached signage. c. Sign design standards. 1) Signs shall not be placed in a manner which interferes, covers, or otherwise disrupts the intended purpose of important architectural building features such as display windows, cornices, vigas, entrances, eaves, and other decorative/integral elements. 2) Signs shall be designed (shape, color, and material) in a manner consistent with the building to which it relates. a) Signs of excessively complicated design, which disrupt the architectural character of the building, shall not be permitted. b) In order to facilitate this compatibility, the following shall apply: (1) Freestanding signs. (a) Design elements and/or finish treatments such as stucco or brick surfacing, freestanding wall designs/treatments, etc. shall be incorporated into a monument sign's overall design except that the copy portion of the sign shall be constructed of wood. (b) Color. The color of surface or finish materials used on the building shall be incorporated into the sign's supporting structure. Contrasting colors may be used on the copy portion of the sign for purposes of increased legibility and clarity. A maximum of two contrasting colors shall be used. (c) When multiple ground signs are allowed (i.e. business centers), the design of each sign shall maintain a similar design appearance, and colors and lettering styles shall remain consistent. (d) The base of all ground signs shall be landscaped with shrubs and ground cover. (2) Attached signs. (a) Signs may be constructed of channel letters, or wood; except, only one style may be used per building or development. If channel letters are used, a logo of the same construction type may also be incorporated into the sign(s) design. (b) Contrasting colors may be used in the sign's design for clarity and legibility; however, a maximum of two such colors, exclusive of background color, are allowed for signs used by each business. For purposes of this provision, the background color must not be used to highlight the sign message and must, therefore, be a color applied in a consistent manner to building or structure walls/surfaces within the development. d. Lighting. 1) If a sign is externally lighted, the lighting fixture shall be decorative in its construction and be compatible to the architectural style of the building to which it relates. 2) Other illumination options include both internal and back lighting. 3) When a sign is lighted, there shall be no glare off the sign due to the lighting utilized with the sign. e. Neon signs. 1) The use of neon is permitted provided it is used for back lighting purposes only. The neon tubing shall be completely shielded from view (as viewed from the front of the subject sign) by the sign's letters or sign structure it is intended to back light. Only one color of neon may be used to back light signs placed upon a building or within a development. f. Legibility and clarity. 1) To facilitate legibility and sign clarity, the number of different lettering styles or fonts and font sizes on a sign shall be kept to a minimum. 2) Lettering shall not be crowded onto a sign and ample space surrounding the copy shall be maintained. 6. Transportation. a. Purpose. To improve access to and circulation within the Avenida de Mesilla Gateway overlay zone district, to minimize traffic conflicts along the Gateway, and to encourage the integration of all modes of transportation into the Gateway. The following transportation regulations shall be complied with: 1) Appropriate striping, placement of barriers, surfacing treatments, and other applicable demarcation strategies shall be used to clearly identify circulation patterns. Developments are encouraged to provide bicycle access and parking. 2) The following access/curb cut provisions shall be required along Avenida de Mesilla pursuant to New Mexico State Highway and Transportation Department final approval. The provisions are based on the linear frontage of property along Avenida de Mesilla and are intended to promote shared access and increase overall ingress/egress efficiency and safety. Frontage | Provision <200 feet | One shared or one two-way or one one-way pair >200—<300 feet | Two shared or one two-way or one one-way pair >300 feet | Two shared (and either one two-way or one one-way pair) or two two-way or two one-way pair a) Access designs which incorporate acceleration/deceleration lanes and other similar traffic flow strategies, which may impact access/curb cut needs, will require the review and approval of plans by the city's public works director or designee and New Mexico State Highway and Transportation Department. b) Non-shared curb cuts shall maintain a five-foot side yard setback. c) A 50-foot separation between curb cuts as measured along the property line shall be maintained regardless of type. d) The width for one-way curb cuts shall be 15 feet. The width for two-way and shared curb cuts shall be no less than 25 feet and no greater than 35 feet. e) Shared access shall be strongly encouraged. f) Shared access provisions shall be secured by a shared access agreement between affected property owners and shall be approved as to form and content by the city attorney's office. Final agreements shall be filed at the county clerk's office. 3) Parking. In order to minimize the impacts often created by parking lots, parking requirements along the Gateway shall follow all applicable parking standards as provided in section 38-58, off-street parking, of this Code, except as follows: a) Businesses located along the Gateway are encouraged to seek shared parking agreements with businesses on adjoining properties. (1) These agreements shall be approved as to form and content by the city attorney's office and once completed, filed with the county clerk's office. (2) Agreements may be made with adjoining property owners regardless of each business' hours of operation. (3) In combining parking requirements, 100 percent of the required off-street parking for all subject businesses shall be met. (4) For businesses requiring a shared parking arrangement in order to meet parking provisions, the agreement shall pertain to no more than 40 percent of the number of parking stalls they are responsible to provide. The remaining 60 percent must be provided on that business' site. b) Lighting standards used to illuminate parking lots shall relate in design, material, and color to the architectural and/or historical character of the property. c) All lighting shall be fully shielded fixtures with full cut-off, 20 percent below horizontal. F. Administration of overlay plan district. 1. Purpose. All new development, including subdivisions and signs, shall require city approval. Proposals involving any development within the Avenida de Mesilla Gateway area shall be processed through the city's staff to aid in enforcing area standards. a. Submittal and review process. 1) Purpose. Submittal and review procedures are established for all new development to protect persons and property within the district as directed in the Avenida de Mesilla Gateway Plan. 2) Subdivisions. For submittal and review of subdivisions within the district, refer to article VI, alternate summary procedures, City Subdivision Code. 3) Buildings. a) Pre-application conference. (1) Prior to the filing of an application for developments in the district, it is strongly encouraged that the applicant meet with staff of the city community development department to review the proposed project. (2) At the conference, staff shall review the development proposal and advise the applicant concerning the compatibility of the proposal with the intent and standards of the Avenida de Mesilla Gateway plan and all other applicable city codes. b) Application procedure. Upon submittal of the required items, the application materials will be processed to the appropriate city departments. Written comments and recommendations from the reviewing agencies will be forwarded to the community development department within ten working days from the date of submittal. c) Application materials. (1) Applications for development within the Avenida de Mesilla Gateway overlay zone district shall be obtained from the community development department, building permit section. (2) Development submittal requirements, including the development statement shall, at a minimum, reflect the following information: (Number of copies to submit with the application is outlined in the Avenida de Mesilla Gateway overlay zone district application packet, available at the city community development department.) (a) A statement of objectives to be achieved by the development inclusive of a description of the character and anticipated use of the proposed development. (b) Scaled site plan. (i) Property boundaries. (ii) Location of all structures. (iii) Parking layout. (iv) Location of service and loading areas. (v) Pedestrian and bicycle circulation. (vi) Dumpster location. (vii) Areas proposed for landscaping. (viii) Ingress/egress access points. (ix) Identification of proposed uses within each structure. (x) Storm water ponding areas. (xi) Surfacing material for impervious surfaces. (xii) Setbacks. (xiii) Any other information which conveys how the proposal will meet development requirements. (c) Scaled floor plan. The scaled floor plan shall clearly identify the internal boundaries, size, and storage areas of each use. (d) Scaled landscaping plan. (i) This plan shall include the location, size, and common name of all landscaping. (ii) A complete irrigation plan shall be included, clearly identifying how the landscape will be sustained. (e) Scaled elevations. (i) The diagram shall include each directional view of all structures clearly identifying exterior building materials and treatments. (ii) Location and treatment of all fenestrations and other building openings shall also be indicated on plans. (iii) Building ornamentation shall be shown. (iv) Roof design and roof surfacing material shall be indicated on diagram. (f) Architectural/artistic renderings. (i) Renderings shall reflect the exterior building. (ii) Drawings shall demonstrate the use of building materials. (iii) Renderings shall indicate selected colors. 4) Signs. a) Sign permits shall be required for all signs within the district. While sign permits are approved separately from all other required permits and applications, the department strongly encourages the display of signage included in the aforementioned submittal material F.1.a.3)c)(2)(b) through F.1.a.3)c)(2)(f). b) All application and submittal material can be obtained from the city planning office. Once the application has been deemed complete and approved, a sign permit will be issued by the city's sign administrator. b. Appeals. 1) Any applications for developments must be approved by the city in order for a building permit to be issued. 2) In the event that an application is denied by the city staff, based on interpretation of the Gateway plan and this Code, an agreement of interpretation cannot be reached, and all other procedures established by this section have been exhausted, the applicant may file for an appeal, in writing, to the Planning and Zoning Commission within 15 days of the city staff's denial decision. 3) The appeal will be processed by the city to be considered at the next available public hearing in accordance with notice requirements of section 38-10 of this Code. 4) Any aggrieved person that is affected by a decision of an administrative official, commission, committee, or board in the enforcement of the Avenida de Mesilla Gateway plan and this section may appeal such decision to the city council in accordance with section 38-13 of this Code. 5) Any person aggrieved by a determination of the city council may appeal to the district court within 30 days after the determination made by city council, in accordance with section 38-14 of this Code. c. Variances. 1) Variances in the numerical requirements for development within the district may be granted by the Planning and Zoning Commission at a public hearing in accordance with section 38-11 of this Code. 2) An application for a numerical variance will be processed to applicable city departments. 3) Written comments from the applicable city departments shall be forwarded to the city community development department within ten working days of the submittal. 4) Comments from the community development department shall be delivered to the Planning and Zoning Commission prior to the public hearing. 5) Decisions of the Planning and Zoning Commission may be appealed to city council, in accordance with the provisions of section 38-13 of this Code. G. Enforcement of overlay zone district. Provisions to enforce this section shall be consistent with the enforcement provisions of section 38-16 of this Code. [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code] [image omitted; see the official code]
(Ord. No. 2354, § I, 1-22-07)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.
