§ 39-11 — Commercial lighting

Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 39-11

Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/be5fb07e-e5f9-4211-8481-52b8ee3d484d

Sec. 39-11. - Commercial lighting.

(a) Total initial lumens per property. (1) The total installed initial lamp lumens of all outdoor lighting systems on the property shall not exceed the total site lumen limit. The total property lumen limit shall be determined using either the parking space method (Table A) or the hardscape area method (Table B). Only one method shall be used per permit application, and for properties with existing lighting, existing lighting shall be included in the calculation of total installed lumens. (2) The total installed initial lamp lumens is calculated as the sum of the initial lamp lumens for all luminaires tested with relative photometry and 140 percent of initial lamp lumens for all luminaires tested with absolute photometry. Table A - Allowed Total Initial Lumens Per Property for Commercial Outdoor Lighting, Per Parking Space Method May only be applied to properties up to ten parking spaces (including handicapped accessible spaces). LZ-0 | LZ-1 | LZ-2 | LZ-3 | LZ-4 500 Ims/space | 700 Ims/space | 900 Ims/space | 1,200 Ims/space | 1,500 Ims/space Table B - Allowed Total Initial Lumens Per Property for Commercial Outdoor Lighting, Hardscape Area Method May be used for any project. When lighting intersections of property drives and public streets or road, a total of 600 square feet for each intersection may be added to the actual property hardscape area to provide for intersection lighting. LZ-0 | LZ-1 | LZ-2 | LZ-3 | LZ-4 1.5 lumens per s.f. of hardscape | 2.5 lumens per s.f. of hardscape | 4.0 lumens per s.f. of hardscape | 8.0 lumens per s.f. of hardscape | 12.0 lumens per s.f. of hardscape (b) Limits to off-site impacts. All luminaires, unless noted otherwise, shall be rated and installed according to Table C. Table C - Maximum Allowable Backlight, Uplight and Glare (BUG) Ratings A luminaire may be used if it is rated for the lighting zone of the property or lower in number for all ratings B, U and G. Luminaires equipped with adjustable mounting devices permitting alteration of luminaire aiming in the field shall not be permitted. A luminaire certified as a full cutoff luminaire shall be deemed as meeting the uplight requirement. Allowed Backlight Rating | Zones LZ-0 | LZ-1 | LZ-2 | LZ-3 | LZ-4 Greater than 2 mounting heights from property line | B1 | B3 | B4 | B5 | B5 1 to 2 mounting heights from property line and properly oriented * | B1 | B2 | B3 | B4 | B4 0.5 to 1 mounting heights from property line and properly oriented * | B0 | B1 | B2 | B3 | B3 Less than 0.5 mounting height to property line adjacent to a street and properly oriented * ** | B0 | B0 | B1 | B2 | B3 Less than 0.5 mounting height to property line and properly oriented * | B0 | B0 | B0 | B1 | B2 Allowed Uplight Rating | U0 | U0 | U1 | U2 | U3 Allowed Glare Rating ** | G0 | G1 | G2 | G3 | G4 Building Mounted Luminaires only *** Greater than 2 mounting heights to any property line | G0 | G1 | G2 | G3 | G4 Building Mounted Luminaires only *** 1 to 2 mounting heights to any property line | G0 | G0 | G1 | G1 | G2 Building Mounted Luminaires only *** 0.5 to 1 mounting heights of any property line | G0 | G0 | G0 | G1 | G1 Building Mounted Luminaires only *** Less than 0.5 mounting heights of any property line | G0 | G0 | G0 | G0 | G1 * The luminaire must be mounted with backlight towards the property line. ** For property lines that abut public walkways, bikeways, plazas, and parking lots, the property line may be considered to be five feet beyond the actual property line for purpose of determining compliance with this section. For property lines that abut public roadways and public transit corridors, the property line may be considered to be the centerline of the public roadway or public transit corridor for the purpose of determining compliance with this section. NOTE: This adjustment is relative to Table C only and shall not be used to increase the lighting area of the site. *** Building-mounted luminaires that cannot be mounted with their backlight to the property line shall meet the allowed glare rating for all luminaires. Light from a building-mounted luminaire must not exceed the B rating in the direction to the property line. _____ (c) Automatic daylight switching requirements. (1) Controls shall be provided that automatically extinguish all outdoor lighting when sufficient daylight is available using a control device or system such as a photoelectric switch, astronomic time switch or equivalent functions from a programmable lighting controller, building automation system or lighting energy management system. All time switches, programmable lighting controller, building automation system or lighting energy management system shall be capable of retaining programming and the time setting during loss of power for a period of at least ten hours. (2) Automatic lighting controls are not required for the following: a. Lighting under canopies. b. Lighting for tunnels, parking garages, garage entrances, and similar conditions. c. Approved emergency outdoor lighting. (d) Automatic lighting reduction requirements. (1) Total outdoor lighting lumens shall be reduced (by at least 30 percent) or extinguished at 11:00 p.m. or 30 minutes after the close of business, whichever is later. (2) Lighting reductions are not required for any of the following: • Approved emergency outdoor lighting • When there is only one luminaire on the property • Code required lighting for steps, stairs, walkways, and building entrances • When in the opinion of the building official, lighting levels must be maintained • Motion activated lighting • Lighting governed by special use permit in which times of operation are specifically identified • Businesses that operate on a 24-hour basis • Approved architectural illumination • Approved flag lighting • Approved signs and billboards • Lighting for single-family dwelling units on commercial properties (e) Emergency outdoor lighting. (1) The lumens allowed for approved emergency outdoor lighting shall be allowed in addition to the total property lumen limit for that property. (2) Approved emergency outdoor lighting shall not be subject to the limits to off-site impacts for that property. (3) Approved emergency outdoor lighting shall not be subject to the automatic lighting reduction requirements. Approved emergency outdoor lighting shall not be subject to the automatic switching requirements. (f) Architectural illumination. (1) A separate allowance of lumens for architectural lighting will be allowed in the amount of ten percent of the calculated total property lumens. (2) This allowance is in addition to the total property lumen limit. (3) The luminaires used for architectural lighting shall be designed, fitted and aimed to shield the lamp and its reflective surfaces from off-site view and to place the light output onto and not beyond the building and shall not be subject to the limits to off-site impacts for that property. (g) Single-family dwelling units on commercial properties. Lighting for a single-family dwelling unit(s) on a commercial property, as allowed by the Las Cruces Zoning Code, shall conform to the requirements for residential lighting and shall be in addition to the total property lumen limit.

(Ord. No. 2781, § I(Exh. A), 5-2-16)

Ask a question about Las Cruces law

Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.