§ 39-8 — Definitions
Municipal Code of the City of Las Cruces, New Mexico (Supp. No. 34: codified through Ordinance No. 3114, adopted June 1, 2026) · Las Cruces Development Code § 39-8
Corpus is an independent public-information project, not the official City of Las Cruces website. Stable reference: corpuslaw.us/code/19cd7a35-5381-4ef7-886b-0a540a0c1def
Sec. 39-8. - Definitions.
This chapter contains only those definitions essential to the proper application of this chapter. It is not intended to include commonly defined general terms or commonly defined technical terms from related codes and standards. [Commonly defined general terms include those terms defined in general English language dictionaries and terms that are not used in a unique or restricted manner in this chapter.] As used in this chapter, the following words and phrases shall have the meanings ascribed to them in this section: Absolute photometry means a photometric measurement (usually of a solid-state luminaire) that directly measures the output of the luminaire. Reference Standard IES LM-79. Addition means an extension or increase in floor area, number of stories, height of a building or structure, or parking spaces. Alteration—Level 1 means an alteration which includes the removal and replacement or the covering of existing materials, elements, equipment, or fixtures using new materials, elements, equipment, or fixtures that serve the same purpose. Alteration—Level 2 means an alteration which includes the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment. Alteration—Level 3 means an alteration in which the work area exceeds 50 percent of the aggregate area of the building. Approved means acceptable to the building official or designee. Architectural lighting means lighting designed to reveal architectural beauty, shape and/or form and for which lighting for any other purpose is incidental. Astronomic time switch means an automatic lighting control device that switches outdoor lighting relative to time of solar day with time of year correction. Backlight means, for an exterior luminaire, flux radiated in the quarter sphere below horizontal and in the opposite direction of the intended orientation of the luminaire. For luminaires with symmetric distribution, backlight will be the same as front light. BUG means a luminaire classification system that evaluates backlight (B), uplight (U) and glare (G). Candela means the basic SI (Systeme International d'Unities) unit of luminous intensity. One candela is one lumen per steradian. Canopy means a covered, unconditioned structure with at least one side open for pedestrian and/or vehicular access. (An unconditioned structure is one that may be open to the elements and has no heat or air conditioning.) Change of occupancy means where the use in a space changes from one group of occupancies to another group of occupancies or changes from one division to another division in the same occupancy group (as defined in the International Building Code). Commercial property means all properties not defined in residential. Curfew means a time defined by this chapter, when outdoor lighting is reduced or extinguished. Electronic variable message display means any sign capable of displaying words, symbols, figures, or images that can be electronically changed by remote or automatic means. Such signs may include the following modes of operations: (1) Static. Signs which include no animation or effects simulating animation. (2) Travel. Signs where the message is changed by the apparent horizontal movement of the letters or graphic elements of the message. (3) Scrolling. Signs where the message is changed by the apparent vertical movement of the letters or graphic elements of the message. Emergency outdoor lighting means generally, lighting that is only energized by an emergency power source; or to illuminate the path of egress solely during a fire or other emergency situation; or, lighting for security purposes used solely during an alarm. Flood lamp means a specific form of lamp designed to direct its output in a specific direction (a beam) with a reflector formed from the glass envelope of the lamp itself, and with a diffusing glass envelope. Such lamps are so designated by the manufacturers and are typically used in residential outdoor area lighting. Fluorescent lamp means a lamp which use fluorescence of a phosphor to produce visible light. Footcandle means a unit of measure expressing the quantity of light received on a surface. One footcandle is the illuminance produced by a candle on a surface one foot square from a distance of one foot. The footcandle is equal to one lumen per square foot. Forward light means, for an exterior luminaire, flux radiated in the quarter sphere below horizontal and in the direction of the intended orientation of the luminaire. Full cutoff luminaire (FCO) means a luminaire where zero candela occur at or above an angle of 90 degrees and a maximum of ten percent candelas at 80 degrees above the nadir of the installed luminaire. This applies to all lateral angles around the luminaire. Such candela information shall be determined by a photometric test report from a nationally recognized independent testing agency and as certified by the manufacturer. Fully shielded means: (1) A luminaire that is certified by the manufacturer as "full cut off" [as defined by IESNA (Illuminating Engineering Society of North America)] and supported by a photometric test report from a third party testing agency and installed according to the manufacturer's instructions. (2) A luminaire approved by the International Dark-Sky Association (IDA) as dark sky friendly and bearing the IDA fixture seal of approval and installed according to the manufacturer's instructions. (3) A luminaire constructed and installed in such a manner that all light emitted by the luminaire, either directly from the lamp or a diffusing element, or indirectly by reflection or refraction from any part of the luminaire, is projected below the horizontal plane through the luminaire's lowest light-emitting part. This can be determined by a photometric test by a design professional. Any structural part of the luminaire providing this shielding must be permanently affixed. (4) A luminaire that is shielded by building canopies, overhangs, roof eaves, and similar types of construction which prevents direct or reflected emission of light above the horizontal. This can be determined by a photometric test by a design professional. Fully shielded residential means a luminaire with opaque top and sides, capable of only emitting light only in the lower photometric hemisphere as installed. Glare means lighting entering the eye directly from luminaires or indirectly from reflective surfaces that causes visual discomfort or reduced visibility. Hardscape means permanent hardscape improvements to the site including parking lots, drives, entrances, curbs, ramps, stairs, steps, medians, walkways and non-vegetated landscaping that is ten feet or less in width. Hardscape area means hardscape area measured in square feet that is used to calculate the total site lumen limit. Refer to hardscape definition. High intensity discharge (HID) lamp means a lamp that produces visible light directly by the electrical heating or excitation of a gas. Examples of such lighting include, but are not limited to: Metal halide, high pressure sodium, and low pressure sodium. For purposes of this chapter, fluorescent lights are not considered HID lighting. Historic building means any building or structure that is listed in the State or National Register of Historic Places; designated as a historic property under local or state designation law or survey; certified as a contributing resource within a National Register listed or locally designated historic district; or with an opinion or certification that the property is eligible to be listed on the National or State Register of Historic Places either individually or as a contributing building to a historic district by the State Historic Preservation Officer or the Keeper of the National Register of Historic Places. Illuminance means the density of luminous flux incident upon a surface. Illuminance is measured in footcandles (lumens/square foot) or lux (lumens/square meter). Incandescent lamp means a lamp which produces light via an electrically heated metallic filament. Initial lumens means a lamps light output, in lumens, at initial installation. The manufacturer usually lists initial lumens. For example, a 100-watt incandescent lamp emits approximately 1,800 lumens. Lamp means a generic term for a source of optical radiation (i.e., "light"), often called a "bulb" or "tube". Examples include incandescent, fluorescent, high-intensity discharge (HID) lamps, and low pressure sodium (LPS) lamps, as well as light-emitting diode (LED) modules and arrays. Landscape lighting means lighting designed specifically for illuminating exterior natural features. Light emitting diode (LED) means a semi-conductor device that emits light when an electrical current is passed through it. Light pollution means any adverse effect of artificial light including, but not limited to, glare, light trespass, skyglow, energy waste, compromised safety or security, and impacts on the nocturnal environment. Light trespass means light that falls beyond the property it is intended to illuminate. Lighting means "electric" or "manmade" or "artificial" lighting. See "Lighting equipment". Lighting equipment means equipment specifically intended to provide gas or electric illumination, including but not limited to, lamp(s), luminaire(s), ballast(s), poles, posts, lens(s), and related structures, electrical wiring, and other necessary or auxiliary components. Lighting system means, on a site, all exterior electric lighting and controls. Lighting zone means an overlay zoning system establishing legal limits for lighting for particular parcels, areas, or districts in a community. Lot means a portion of a subdivision or other parcel of land intended for the purpose, whether immediate or future, for development. It also is a tract of land described by metes and bounds and as shown on the records in the county assessor's office. Used interchangeably with "property". Low voltage landscape lighting means landscape lighting powered at less than 15 volts and limited to luminaires having a rated initial luminaire lumen output of 750 lumens or less. Lumen means the unit of measure used to quantify the amount of light produces by a lamp or emitted from a luminaire (as distinct from "watt", a measure of power consumption). Luminaire means the complete lighting unit (fixture), consisting of a lamp, or lamps and ballast(s) (when applicable), together with the parts designed to distribute the light (reflector, lens, diffuser), to position and protect the lamps, and to connect the lamps to the power supply. Luminaire lumens means the cumulative total of initial lumens emitted by all lamps contained within a single luminaire. For luminaires with relative photometry per Illuminating Engineering Society (IES), it is calculated as the sum of the initial lamp lumens for all lamps within an individual luminaire, multiplied by the luminaire efficiency. If the efficiency is not known for a residential luminaire, assume 70 percent. For luminaires with absolute photometry per Illuminating Engineering Society (IES) LM-79, it is the total luminaire lumens. The lumen rating of a luminaire assumes the lamp or luminaire is new and has not depreciated in light output. Luminance means a measure of the brightness of a surface which is emitting light. The unit of measurement most commonly used is candelas per square meter, often referred to as nits in the U.S. (one nit = one cd/m 2 ). Mounting height means the height of the photometric center of a luminaire above grade level. New lighting means lighting for areas not previously illuminated or newly installed lighting of any type except for replacement lighting or lighting repairs. Outdoor lighting means lighting located exterior to a structure or that illuminates areas exterior to a structure. Outdoor luminaire means any lighting device located exterior to a structure or that illuminates areas exterior to a structure, whether permanently or temporarily installed. This includes, but is not limited to: • Search light • Spotlight • Flood light • Security lighting • Sign and architectural lighting • Lighting for parks, parking lots, roadways • Athletic facility lighting • Building overhang and open canopy lighting • Product display area lighting • Landscape lighting • Signs or billboards whether on-premises or off-premises, including LED, plasma and similar light sources Partially shielded luminaire means a luminaire with opaque top and translucent or perforated sides, designed to emit most light downward. Photoelectric switch means a control device employing a photocell or photodiode to detect daylight and automatically switch lights off when sufficient daylight is available. Property line means the edge of the legally-defined property or lot. Relative photometry means photometric measurements made of the lamp plus luminaire, and adjusted to allow for light loss due to reflection or absorption within the luminaire. Repair(s) means the reconstruction or renewal of any part of an existing luminaire for the purpose of its ongoing operation, other than relamping or replacement of components including capacitor, ballast or photocell. Note that retrofitting a luminaire with new lamp technology or ballast technology is not considered a repair and for the purposes of this chapter the luminaire shall be treated as if new. Replacement lighting means lighting installed specifically to replace existing lighting that is sufficiently broken to be beyond repair. Residential means detached one- and two-family dwellings and townhouses not more than three stories above grade plane with a separate means of egress as defined in the International Residential Code as adopted by the City of Las Cruces. Seasonal lighting means temporary lighting installed and operated in connection with holidays or traditions. Shielded directional luminaire means a luminaire that includes an adjustable mounting device allowing aiming in any direction and contains a shield, louver, or baffle to reduce direct view of the lamp. Sign means advertising, directional or other outdoor promotional display of art, words and/or pictures. Spot lamp means a specific form of lamp designed to direct its output in a specific direction (a beam) with a reflector formed from the glass envelope of the lamp itself, and with a clear or nearly clear glass envelope. Such lamps are so designated by the manufacturers, and typically used in residential outdoor area lighting. Temporary lighting means lighting installed and operated for periods not to exceed 60 days, completely removed and not operated again for at least 30 days. Third party means a party contracted to provide lighting, such as a utility company. Total initial lumens means the sum of the individual initial lumens output for all the luminaires of an installation. For example, six luminaires with 10,000 initial lumens output per luminaire would equal 60,000 total initial lumens. Translucent means a material allowing light to pass through, but obscures or diffuses the image (not transparent or clear). Unshielded luminaire means a luminaire that does not meet the definition of "fully shielded" or "partially shielded". Uplight means, for or an exterior luminaire, flux radiated in the hemisphere at or above the horizontal plane.
(Ord. No. 2781, § I(Exh. A), 5-2-16)
Ask a question about Las Cruces law
Corpus searches the Las Cruces sections it holds and shows the ones that match, with their citations. Free, no sign-in.
