§ 51.08 — SERVICE CONNECTIONS
Municipal Code, City of Rio Rancho, New Mexico (Code 2026-04-23) · Rio Rancho Municipal Code § 51.08
Corpus is an independent public-information project, not the official City of Rio Rancho website. Stable reference: corpuslaw.us/code/aa69c82e-f4c6-41ff-af2b-cd91926a086c
§ 51.08: SERVICE CONNECTIONS.
(A) General. (1) The utility shall determine the point of service to any premises. The customer shall contact the utility for exact information regarding the water and/or sewer service line location before any piping in the interior of the building has been started. If such information is not secured, the utility shall not be held liable in any way, and will not assume any responsibility, for changes in piping installation that may result. (2) No more than one water or sewer service line shall be installed on the premises for any one customer unless agreed to by the utility. If there is more than one water service line on a customer’s premises, each water service line will be separately metered and billed. (3) Water or sewer service connections shall be made only by a licensed contractor working for, or as an agent of, a customer. The utility shall charge a service connection fee to the customer. (4) The city shall install all meter settings and the customer shall be charged an installation fee. (5) All piping and plumbing installations made by the customer, or under responsibility of the customer, shall conform to all applicable codes. (B) Water service connections. (1) No more than one single-family residential customer shall be served through any single water service line connection. In the case of a multi-family residential customer, the water service is rendered by a single connection for more than one dwelling unit. (2) The utility’s water service lines shall terminate at the meter assembly and it shall be the owner’s responsibility, and at the owner’s expense, to install a stop and waste valve and to make the necessary connection from the utility’s water service line to the building or buildings to be served. For those systems providing fire protection, the customer shall install a pressure regulating device and an approved backflow prevention assembly. (3) All meters are installed as close as possible to the property line, provided there is public access to the meter location. All water service will be provided by the utility through an appropriate type and size meter. (4) The customer shall install a shutoff valve or equivalent on a yard line (customer’s line) in an accessible place on the premises. (5) Where the customer’s water pressure requirements are less than the minimum water pressure of 30 p.s.i., or more than the maximum water pressure of 125 p.s.i., then the customer is responsible to provide and install an approved adjustable pressure regulation device at the customer’s expense. Customers shall not connect pumps directly to their water service line. (6) Backflow prevention assemblies shall be required in the construction of all new commercial, industrial, and public authority services where water is used in any process which, in the opinion of the utility, could constitute a cross-connection or health hazard. The type of backflow prevention assembly to be used shall be determined by the utility (Chapter 54, Backflow Prevention and Cross Connection Control Program). (7) The customer shall contact the utility for its determination regarding the location of the backflow prevention assembly and the type of backflow prevention assembly required to be used before the customer installs the water service line. If such determination is not secured, the utility shall not be held liable in any way and will not assume any responsibility for expensive changes in piping installation that may result. (C) Sewer service connections. (1) Only one sewer connection per single-family residential customer is allowed. In the case of multi-family residential customers, sewer service is provided by one or more connections from the dwelling unit. (2) It shall be the customer’s responsibility and expense to connect from the utility’s sewer main line to the building or buildings to be served. (3) The customer shall install a cleanout access or equivalent on a yard line (customer’s line) in an accessible place on their premises. (4) Wastewater discharge monitoring manholes shall be required in the construction of all new nonresidential sewer lateral lines. Such manholes shall be installed at the customer’s expense at a point on the sewer lateral line to be determined by the utility. The customer shall contact the utility for determination regarding the location of the manhole and the type and size of the manhole apparatus to be used before the customer installs the sewer lateral line. If such determination is not secured, the utility shall not be held liable in any way and will not assume any responsibility for expensive changes in piping installation that may result.
(Am. Ord. 04-044 ; Am. Ord. 18-14 )
Ask a question about Rio Rancho law
Corpus searches the Rio Rancho sections it holds and shows the ones that match, with their citations. Free, no sign-in.