§ 51.47: GREASE INTERCEPTORS.
Any establishment determined by the Director to be a FOG-contributor will be required to install a grease interceptor in accordance with the City of Rio Rancho Building Code. Grease interceptors will be installed and adequately designed and sized based on the facility flow and performance expectations and in conformance with the city’s current Uniform Plumbing Code. It is the responsibility of the FOG-contributor to maintain, repair and, if necessary, replace the grease interceptor and all plumbing associated with it. (A) Existing FOG-contributors. (1) Any or all grease interceptors already in place are required to be maintained and cleaned of their entire contents on a routine schedule, at least quarterly, but as often as necessary to keep the sewer system free from FOG. An interceptor may be required at the discretion of the Director for good cause, including, but not limited to, belief that a grease blockage in the collections system was due to or exacerbated by the FOG-contributor. A grease interceptor will also be required at the discretion of the Director if the facility changes ownership or if remodeling or production changes at the facility warrant. Upon notification by the Director that a grease interceptor is required, it will be the responsibility of the FOG-contributor to submit the following information, which shall include at a minimum: (a) The size and type of interceptor to be installed; and (b) Contact information about the contractor. (2) Upon completion of installation, the Director shall confirm the installation. (B) New FOG-contributors. (1) New businesses are required to install a Uniform Plumbing Code sanctioned grease interceptor before discharging to the POTW. Exceptions may be allowed when, in the opinion of the Director, there is minimal grease discharge anticipated. Decisions of the Director are considered final administrative actions for purposes of judicial review. (2) At the discretion of the Director in accord with the City of Rio Rancho Building Code, the size of an existing interceptor will be required to be increased or decreased if required to provide better protection to the sewer system. Upon notification by the Director that a differently sized grease interceptor is required, it will be the responsibility of the FOG-contributor to submit the following information, which shall include at a minimum: (a) The size and type of interceptor to be installed; and (b) Contact information about the contractor. (3) The Director will review all modifications or installations, and notify the FOG-contributor of additional requirements. Upon completion of installations and modifications, the Director, in accord with the City of Rio Rancho Building Inspection Division, shall confirm the installation and modification. (4) All grease interceptors shall be cleaned of their entire contents on a routine schedule, at least quarterly, but as often as necessary to keep the sewer system free from FOG. At no time will the interceptor be more than 30% full with solids, semi-solids, and grease. Interceptor cleaning must be performed by a waste hauler who is registered in the city, as set forth in Section 51.49, who holds a current and valid liquid waste disposal permit from a local facility/agency, and disposed of or recycled properly in accordance with all laws regulating such disposal/recycling. In all circumstances, the user shall be responsible for the proper removal and legal disposal of the grease interceptor/trap waste. All waste removed from each grease interceptor/trap must be disposed of at a facility permitted to receive such waste. In no manner shall any pumped grease interceptor contents be discharged to the city’s sewer system. (5) Maintenance shall include the complete removal of all contents, including floatable materials, wastewater, sludges, and solids. Top skimming of grease interceptors, decanting or back flushing of the grease interceptor or its wastes for the purpose of reducing the volume to be hauled is prohibited. Further, the discharge of liquid, semi-solids, or solids into a grease interceptor/trap from vehicles after servicing is prohibited. It is specifically prohibited to maintain grease traps by enzymatic addition or treatment. (6) The FOG-contributor shall obtain a manifest from the waste hauler and retain it for a period of at least three years as required by law. The original copy or other hard copy or electronic form, as approved by the Director, of the manifests shall be maintained and readily available for inspection and copying by the Director. Manifests must include, at a minimum, the following information: (a) Date; (b) Time; (c) Quantity removed (in pounds or gallons); (d) Quantity of grease trap waste disposed (in pounds or gallons); (e) Name, address, telephone number of the company hauling the waste; (f) Name and signature of the driver; (g) Disposal destination. (7) If any blockage or restriction occurs in the sewer system and if the identified source failed to properly install or maintain a grease interceptor, the city has the right to bill such an establishment for costs incurred by the city to alleviate the blockage or restriction. Any fines or penalties incurred by the city that are related to the blockage or restriction shall also be paid by the responsible establishment. If more than one source is identified, responsible parties will share the cost, as determined by the Director.
( Ord. 06-74 ; Am. Ord. 18-14 . Formerly 51.46 )
Ask a question about Rio Rancho law
Corpus searches the Rio Rancho sections it holds and shows the ones that match, with their citations. Free, no sign-in.