§ 51.75: SAMPLING REQUIREMENTS FOR USERS.
(A) Except as indicated in subsections (B) and (C) of this section, the user must collect wastewater samples using 24-hour composite sampling techniques, unless time-proportional composite sampling or grab sampling is authorized by the Director. Where time-proportional composite sampling or grab sampling is authorized by the city, the samples must be representative of the discharge. Using protocols, including appropriate preservation specified in 40 CFR Part 136 and appropriate EPA guidance, multiple grab samples collected during a 24-hour period may be composited prior to the analysis as follows: for cyanide, total phenol, and sulfides, the samples may be composited in the laboratory or in the field; for volatile organics and oil and grease, the samples may be composited in the laboratory. Composite samples for other parameters unaffected by the compositing procedures as documented in approved EPA methodologies may be authorized by the city, as appropriate. In addition, grab samples may be required to show compliance with instantaneous limits (40 CFR 403.12(g)(3)). (B) Samples for oil and grease, temperature, pH, cyanide, total phenols, sulfides, and volatile organic compounds must be obtained using grab collection techniques. (C) Samples should be taken immediately downstream from pretreatment facilities if such exist or immediately downstream from the regulated or manufacturing process if no pretreatment exists or as determined by the city and contained in the user’s wastewater discharge permit. For CIUs, if other wastewaters are mixed with the regulated wastewater prior to pretreatment, the user must: (1) take the sample directly from the undiluted categorical process, or (2) measure the flows and concentrations necessary to allow use of the combined wastestream formula of 40 CFR 403.6(e) in order to evaluate compliance with the applicable categorical Pretreatment Standards. For other SIUs for which the city has adjusted its local limits to factor out dilution flows, the user should measure the flows and concentrations necessary to evaluate compliance with the adjusted pretreatment standard(s). (D) For sampling required in support of baseline monitoring and 90-day compliance reports, a minimum of four grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfides, and volatile organic compounds for facilities for which historical sampling data do not exist; for facilities for which historical sampling data are available, the Director may authorize a lower minimum. For the reports required in Section 51.65(A) (40 CFR 403.12(e) and 403.12(h)), the user is required to collect the number of grab samples necessary to assess and assure compliance with applicable pretreatment standards and requirements. (E) All sample results shall indicate the time, date and place of sampling and methods of analysis, and shall certify that such sampling and analysis is representative of normal work cycles and expected pollutant discharges from the user. If a user sampled and analyzed more frequently than what was required in its wastewater discharge permit, using methodologies in 40 CFR Part 136, it must submit all results of sampling and analysis of the discharge as part of its self-monitoring report.
( Ord. 06-74 ; Am. Ord. 18-14 . Formerly 51.74 )
Ask a question about Rio Rancho law
Corpus searches the Rio Rancho sections it holds and shows the ones that match, with their citations. Free, no sign-in.