Sec. 7. - Safety precautions.

A. System protection. Wind energy systems shall be constructed to prevent unauthorized persons from climbing onto them. Access to the wind turbines and electrical equipment shall be securely fenced off to prevent unauthorized access, injury, or death from the system components. B. Controls and brakes. All wind energy systems shall be equipped with redundant braking systems. These braking systems shall include aerodynamic over-speed controls which vary the pitch of the blades to slow them down, as well as a fail-safe mechanical braking system, to slow down the rotation speed of the blades at the hub. Stall regulation shall not be considered a sufficient braking system for over-speed protection. C. Wind resistance. Every RAES shall be designed and certified to withstand sustained winds of 90 miles per hour. This is in accordance with the building code requirements adopted and enforced by the city for wind load requirements for exposure-C classifications. D. Batteries. RAES containing batteries for any reason shall comply with all local, state, and federal regulations/guidelines for the safe handling, use, storage and disposal of batteries. E. Clearance. RAES shall be installed on private property, with no part of the system overhanging public rights-of-way. Caution must be taken during the design and planning of the system to ensure the system will interfere with overhead or underground utilities. F. Bottom sweep of propeller. The tips of propellers from a wind energy system at the lowest point in its rotation shall be no closer than ten feet from the existing grade in all installations.

Ask a question about Roswell law

Corpus searches the Roswell sections it holds and shows the ones that match, with their citations. Free, no sign-in.

Use the Roswell code through the API

This call searches the Roswell code. Change jurisdiction to the state's code to search its statutes and its cities, or to US for federal law. A free key gives 1,000 searches a month, and the MCP server works with no key.

curl -H "Authorization: Bearer $CORPUS_API_KEY" \
  "https://corpuslaw.us/api/v1/search?q=Safety+precautions&jurisdiction=NM-ROSWELL"

Law search API · Docs · Get a free key · Connect the MCP server