§ 491-24: Fittings, taps and joints.

A. Fittings. (1) Fittings for assembling copper water tubes shall be cast-bronze flared tube or cast brass or wrought-copper solder type. All such fittings shall be marked with the size and the manufacturer's name or designation. (2) Threaded-type fittings shall be of cast brass or bronze of heavy-beaded steam pattern free from defects and containing the following materials: Material | Minimum(percent) | Maximum(percent) Copper | 80 | 86 Zinc | 4 | 15 Lead | 2 | 6 Tin | 3 | 6 (3) Fittings for wrought-iron galvanized pipe shall be of the threaded type of the same grade material as the pipe. Fittings for cast-iron pipe shall be Class D and shall conform to the latest Specifications for Cast Iron Pressure Fittings (Designation C100) of the American Water Works Association. B. Taps. (1) The maximum size taps permitted for various size water mains shall be as follows: Size of Main(inches) | Size of Tap(inches) 4 | 3/4 6 | 3/4 8 | 1 10 | 1 12 | 1 1/4 16 | 1 1/2 20 | 2 Over 20 | 2 (2) When the condition of the main is such that it will not fully support any of the above sizes or when obstructions prohibit normal installation, then the Commissioner of Public Works may, in his discretion, permit the connection to be made by means of an approved tapping saddle; provided, however, that no taps for domestic or fire supplies shall be installed in thirty-six-inch, forty-eight-inch and sixty-inch transmission mains. (3) Multiple taps for a single service line shall not be permitted. Tapping sleeve and branch valve may be used where a greater volume of water is required than can be obtained through taps above prescribed. Connections to the tapping sleeve and branch valve shall be directed and permitted by the Commissioner of Public Works. (4) At the connection to the corporation cock, a proper regard and allowance for service line flexibility shall be made. Where Type K copper water tube or lead services are installed, an excess of two feet of pipe shall be used for bending of a gooseneck at the water main to provide flexibility. Where SPS copper pipe or SPS eighty-five-percent red brass pipe or extra-heavy wrought-iron galvanized pipe is used, a minimum of three twelve-inch pieces of pipes and fittings shall be used to make a flexible joint at the main. C. Joints. (1) All joints between copper pipe and copper or brass fittings when of solder type only shall be of silver solder or brazed with phoscopper. (2) Caulked joints for cast-iron service pipes shall be made with pure virgin lead free from impurities. The minimum depth of lead for joints up to eight inches in diameter shall be 2 3/8 inches, and for all joints over eight inches in diameter shall be three inches. Approved compounds may be used instead of lead for joining material. The manufacturer's standard recommendations must be followed in using joint compounds. Mechanical joints for cast-iron pipe and fittings shall conform to the latest Specifications for Mechanical Joints for Cast Iron Pressure Pipe and Fittings (designation C111) of the American Water Works Association.

Ask a question about Buffalo law

Corpus searches the Buffalo sections it holds and shows the ones that match, with their citations. Free, no sign-in.