§ 491-32: Safeguarding from freezing.
If there is a vault or area under the sidewalk or in front of any building, service pipe shall run at a sufficient depth below the floor of such vault or area to be secured from freezing. A suitable stop- or waste cock shall be placed in each service directly within the wall of the building and so located as to be secure from freezing and to drain all pipes in the building as a safeguard against freezing and to give the occupant the means of stopping the flow of water in case of leakage or damage to plumbing on the premises.