§ 120-67 — Riverfront District
Municipal Code, City of Rochester, New York (Rochester Municipal Code, City Charter, Zoning Ordinance and Code Tables current through legislation adopted October 20, 2026 (eCode360 publication RO0104, scraped 2026-11-18)) · Rochester Zoning Ordinance § 120-67
Corpus is an independent public-information project, not the official City of Rochester website. Stable reference: corpuslaw.us/code/a31f8f71-0919-4834-aea6-320075abd49d
§ 120-67: Riverfront District.
A. Purpose of the district. The primary purpose of the design criteria for the Riverfront District is to: (1) Preserve the existing character of the riverfront. (2) Promote development compatible with the desirable built character of the riverfront. (3) Improve visual and physical access to the riverfront. (4) Provide uninterrupted public access to the river's edge. (5) Promote the riverfront as a place for public gathering and activity. (6) Reduce the "barrier" effect of the river separating the east and west sides of the Center City; strengthen linkages across the river. B. District boundaries and definition. The boundaries of the Riverfront District were determined by including all areas that had a physical and/or visual connection (literal or implied) to the river. Buildings that expressed character or common design attributes consistent with the character described in "Design Language" were included. The Riverfront District is continuous and uninterrupted along the river corridor within the CCD. [image] C. Design character of the district. The Riverfront District is characterized by pedestrian-scaled buildings with clearly defined bases, midsections and crowns. Buildings range from three to six stories in height and transition upwards as they move away from the water's edge. A thirty-foot buffer is maintained along the river and no structures are allowed in the buffer; pedestrian access to the river is a priority in the district. Buildings are tall, narrow masses with rich materials and colors. Minimum front setbacks create intensified pedestrian-scaled streets with an apparent riverfront theme. D. Design Checklist. The following chart lists the design criteria and the deviations that require major site plan or minor site plan review. Applications that are within acceptable tolerances, and otherwise meet all design criteria, do not require site plan approval unless such approval is required pursuant to the other site plan thresholds as listed in § 120-191 of this chapter. Design Checklist - Riverfront District Design Criteria | Major Deviation | Minor Deviation | Tolerance BUILDINGS Building form and mass | X Minimum lot frontage | X Maximum building length and depth relative to block | | X | 10% Minimum and maximum building height | X Length to height ratio | | X | 20% Orientation to street frontage | X Orientation to river | X Front setback | X Side and rear setback | X Setback at river | X DISTRICT CHARACTER Building maintains horizontal alignment | | X Facade composition | X Equal street/river frontage facades | X Vehicular entry location | | X Vehicular entry door | | X | 20% Facade lighting | | X Window openings | | X Facade window coverage | | X | 10% Window height to width ratio | | X | 20% Windows translucent | | X | 20% Window recess | | X | 30% Entrances on street frontage | X Entrances on riverfront | X Entrance elevation | | X Entrance translucent | | X | 20% Entrance recess | | X | 20% Entrance lighting | | X Roofline | | X Roofline cornice | | X | 20% Rooftop mechanical/telecommunications equipment | | X Primary construction material | | X Percent primary construction material | | X | 20% Number of colors | | X | 50% Location of refuse storage | | X Refuse storage details (enclosures, doors) | | X SIGNAGE Number of building identification signs | | X Location of building identification sign | | X Size of building identification sign | | X | 20% Building identification sign materials | | X Building identification sign luminaries | | X Building identification sign graphics | | X Building identification sign colors | | X | 30% Number of business signs | | X Location of business signs | | X Size of business signs | | X | 20% Projection sign supports | | X Business sign materials, illumination and color | | X | 30% Directory sign location and size | | X | 20% Address sign location | | X Address sign copy raised/recessed | | X Address sign materials | | X Address sign lighting | | X Heritage sign and location | | X Heritage sign material | | X Heritage sign information | | X Heritage sign size | | X | 20% Awning locations | | X Entrance awning size | | X | 10% Window awning size | | X | 10% Awning height | | X | 10% Awning projection | | X | 10% Awning support/attachments | | X Awning material | | X Awning color | | X | 30% Awning equality | | X Awning copy size | | X | 20% Awning lighting | | X SKYWAY Skyway height | | X Interior skyway parallel to exterior facade | | X Skyway width | | X | 10% Skyway nontranslucent walls | | X | 20% Skyway supported from facade | | X Skyway lighting | | X Skyway windows translucent | | X | 10% Skyway entrances direct from building | | X Skyway entrances identified and translucent | | X | 10% Skyway entrance lighting | | X Skyway roofline | | X Skyway material and color | | X Skyway benches quantity | | X Skyway benches size | | X | 20% Skyway interpretive panel size | | X | 20% SITE Building parking location and surfacing | | X Building parking access | | X Building parking lighting | | X Parking lot location | | X Parking lot access | | X Parking lot setback | | X Parking lot setback on river | | X | 10% Parking lot surfacing and curbing | | X Parking lot aisle | | X Parking lot walls setback | | X | 10% Parking lot walls height | | X | 10% Parking lot pedestrian openings | | X | 10% Parking lot landscaping | | X | 20% Parking lot shaded area | | X | 20% Parking lot lighting height | | X | 10% ADDITIONAL AMENITIES Fencing location | | X Fencing/wall setback | | X Fencing height | | X | 10% Fencing material and translucence | | X | 10% Gates equal to fencing | | X Wall location | | X Wall height | | X | 10% Wall materials | | X Riverfront promenade location and width | | X | 10% Riverfront promenade entrance | | X | 10% Riverfront promenade grade elevation | | X Riverfront promenade materials | | X Riverfront promenade benches | | X | 20% Riverfront promenade light level and fixture | | X Riverfront plaza landscaping | | X | 20% Riverfront plaza lighting | | X | 20% E. Design principles for the district. Design principles in the Riverfront District should concentrate on reestablishing the Genesee River as the focus of cultural, social and recreational activity in the Center City. The strengthening of connections both to the riverfront and across the river is essential. The creation of a continuous public space along the riverfront should be promoted in conjunction with human-scaled development along the river. Views and sight lines to the river, from throughout the district, should be enhanced. F. Buildings. (1) District context. (a) Building form and mass. [1] Buildings shall exhibit a tall/narrow mass on the primary street frontage. [image] (b) Lot size and coverage. [1] The minimum lot frontage shall be 30 feet. [image] [2] The maximum building length and depth shall be no more than 25% of the block length and 50% of the block depth. [image] (c) Height. [1] Unless otherwise noted, buildings heights shall include: [a] Main Street: shall be a maximum of six stories in height to a maximum of 72 feet and a minimum of three stories to 30 feet. [b] City street: shall be a maximum of six stories in height to a maximum of 72 feet and a minimum of three stories to 30 feet. [c] District street: shall be a maximum of six stories in height to a maximum of 72 feet and a minimum of three stories to 30 feet. [d] Neighborhood street: shall be a maximum of six stories in height to a maximum of 72 feet and a minimum of three stories to 30 feet. [image] [2] Buildings adjacent to the river shall be set back 30 feet to a maximum of three stories and 60 feet to a maximum of six stories. [image] [3] No building within a three-hundred-foot radius of City Hall shall exceed the height of City Hall, excluding the tower. (d) Length to height ratio. [1] The length to height ratio shall be a maximum 1:2.5 and minimum 1:1 along primary street frontage. [image] (e) Orientation. [1] Buildings shall be parallel to the street frontage property line. [image] [2] Buildings fronting the river shall be parallel to the riverfront. [3] Buildings shall be oriented to preserve and enhance views of the river. (f) Setback. [1] Unless otherwise noted, front yard setback shall be: [a] Main Street: zero feet. [b] City street: zero feet. [c] District street: zero feet. [d] Neighborhood street: zero feet. [image] [2] Side yard setback shall be a maximum of nine feet. [image] [3] Rear yard setback shall be a minimum of nine feet. [image] [4] Street frontage setback shall vary every 30 feet a minimum of two feet and a maximum of four feet. [image] [5] Setback for buildings adjacent to the river shall be a minimum of 30 feet and a maximum of 60 feet from the river's edge. [image] [6] Street frontage setback on streets that cross the river within one block of the river shall be 10 feet. [image] (2) District character. (a) Facade composition. [1] Buildings shall maintain the alignment of horizontal elements of adjacent existing buildings. [image] [2] The facade shall be composed to exhibit a clearly defined base, midsection and crown; the base of the building shall be no higher than the top of the second story. [image] [3] All facades fronting the river, Main Street, or a city, district, or neighborhood street shall conform to the district criteria and be equal. [image] [4] Buildings with river frontage shall be designed with a facade along the river equal in prominence to its primary street facade. [5] All facades higher than adjacent and abutting buildings shall be equal to street facades. [6] Vehicular entrances are permitted on rear and side yards only. Entrances are prohibited on street frontages and along the river. [image] [7] Vehicular entrances shall be enclosed with a garage door, which shall be a minimum of 20% transparent. [image] [8] Facade lighting shall be wall-mounted luminaires historic in character and shall be mounted no higher than the top of the second floor and shall illuminate the sidewalk. No light shall be cast upward. [image] [9] Facade lighting shall conform to Illumination Engineers Society of North America (IESNA) guidelines. No floodlighting is permitted. (b) Window. [1] Windows and window openings shall diminish in size to reinforce the base, midsection and crown. [image] [2] The base shall be a minimum 50% to a maximum 65% window coverage. [image] [3] The midsection shall be a minimum 35% to a maximum 60% window coverage. [image] [4] All other facades and alley street frontages shall be a minimum 25% window coverage. [5] The window height to width ratio shall be 1.5:1 to 2:1 in the midsection. Window openings may be divided with mullions; muntins are permitted. [image] [6] Base windows shall be transparent and shall permit views 10 feet into the building when standing five feet away from the window. [image] [7] Windows shall be recessed three inches to six inches from the facade. [image] (c) Entrance. [1] Entrances into buildings shall be provided on city, district and neighborhood street frontages. Buildings fronting onto Main Street shall have their primary entrance on Main Street. [image] [2] Buildings that face onto the river shall provide a riverfront entrance of equal prominence to the primary facade. [image] [3] Entrances shall be flush with the sidewalk; changes in elevation shall be made internally. [image] [4] Entrances shall be clearly accented and 80% translucent. [image] [5] Entrances shall be recessed from the building face a minimum of three feet. [image] [6] All entrances shall be illuminated and shall conform to facade lighting. [image] (d) Roofline. [1] Rooflines shall be flat. [image] [2] Rooflines shall be delineated with decorative crown cornices a minimum two feet wide. [image] [3] Rooftop mechanical equipment shall be concealed so as to not be visible from the street. [image] (e) Material and color. [1] In addition to the windows, three primary construction materials may be used on a street facade, including clay brick, natural stone, stucco [exterior insulation finish system (EIFS)] or decorative concrete. [image] [2] Excluding windows, a minimum 50% of one primary construction material shall be used. [3] Excluding windows, a maximum of two colors shall be permitted. [image] (f) Refuse storage. [1] Excluding alley streets, refuse storage shall not be located on a street frontage and shall not be visible from the street. [2] Refuse storage areas shall conform to the following: [a] If a loading dock/service bay or vehicular garage is part of the building, refuse storage shall be contained within this area. [image] [b] If there is no loading dock service bay or vehicular garage, refuse storage shall be located within the building, accessible from the exterior and enclosed with a solid metal door. The doors shall be integrated into the facade pattern in a manner consistent with the character of the building. [image] [c] If not located within the building, refuse storage shall be located within a concealed enclosure that includes solid metal doors, is integral to the building, consists of the same materials as the building and is located at the rear of the building. [image] (3) Signage. (a) Building identification signage. [1] One sign shall be allowed on each street frontage. [2] Signs shall not be placed higher than the top of the second floor. [image] [3] Signs shall be integrated into the facade pattern and shall be located above or adjacent to primary building entrances; signs shall be horizontal or vertical and flush mounted. [image] [4] Signs shall be a maximum 2.5 feet high and a maximum 25 square feet. [image] [5] Sign materials shall include any of the district building materials, wood and metal. [6] Sign luminaires shall conform to facade lighting. [7] Sign graphics shall include raised or recessed copy. [8] Signs shall include no more than three colors. (b) Business signage. [1] A maximum of one sign per ground floor commercial user shall be permitted and shall be located no higher than the top of the first floor. [image] [2] Signs shall be integrated into the facade pattern and shall be flush mounted or projecting. [3] Flush-mounted signs shall be a maximum two feet high and a maximum 20 square feet. [image] [4] Projecting signs shall not exceed six square feet in area, shall not project more than four feet from the face of a building and shall be located a minimum of eight feet from the ground. [image] [5] Supports for projecting signs shall be attached to the building facade at no more than two points. [6] Materials, illumination and color shall conform to the criteria for building identification signage. [7] Directory signage shall be allowed at each building entrance, shall be flush mounted and a maximum six square feet. [image] (c) Address signage. [1] One sign shall be located at the primary building entrance no higher than the top of the first floor. [image] [2] Sign graphics shall be raised or recessed copy and shall be a minimum of two inches and a maximum 12 inches in height. [image] [3] Sign materials shall include any of the district building materials and metal. [4] Building lighting shall illuminate the sign. (d) Heritage signage. [1] One sign shall be placed on the primary frontage of each building and shall be located no higher than five feet above finished grade. [2] Signs shall be face mounted to the building facade. [3] Signs shall be made of metal. [4] Signs shall include, at a minimum, the date of construction. [5] The maximum sign area shall be 1.5 square feet. [image] (e) Awnings. [1] Awnings shall be permitted at building entrances and windows no higher than the second floor. [image] [2] At building entrances the maximum width shall be two times the width of the entrance opening. [image] [3] At windows the maximum width shall be the width of the opening. [image] [4] First floor awnings shall be a minimum eight feet and a maximum nine feet above exterior finished elevation at the building. [image] [5] First floor awnings shall project no more than half the width of the sidewalk to a maximum of five feet. [image] [6] Second floor awnings shall project no more than three feet. [image] [7] Awning support shall include building attachments only. [8] Awnings shall be made of flexible woven, natural or synthetic materials. [9] Awning fabric shall include no more than three colors. [10] All window awnings shall be equal in material and color. [11] Awning signage copy shall only include building identification or address located on the valence and shall be a maximum eight inches in height. [12] Awnings shall be illuminated by building lighting only. [image] (4) Skyway. (a) Facade composition. [1] Skyway shall be no higher than the top of the third story. [image] [2] Interior skyway shall run parallel to the exterior building facade. [image] [3] Skyway shall be a minimum 10 feet wide and shall have a minimum seven-foot unobstructed travel width. [image] [4] Skyway nontranslucent walls shall be a maximum two feet high measured from the floor. [image] [5] Skyway shall be supported from the building facade. [6] All light sources shall be concealed and interior. (b) Window. [1] Exterior skyway shall be a minimum 80% translucent. [image] [2] The facade wall of an interior skyway shall be a minimum 50% transparent or as existing. (c) Entrance. [1] Skyway entrances shall provide direct entry from the sidewalk integral to the building. [image] [2] Entrances shall be clearly identified and 80% translucent. [3] All entrances shall be illuminated and shall conform to facade lighting. [image] (d) Roofline. [1] Rooflines shall be pitched or arched. (e) Material and color. [1] Excluding windows, a maximum of two primary construction materials conforming to district building criteria and metal may be used. [image] [2] Excluding windows, a maximum of two colors shall be permitted. [image] G. Site. (1) Parking. (a) Building parking. [1] Building parking shall not be located on the riverfront. [2] Building parking shall not be located at Main Street intersections and at all intersecting city streets. [3] Building parking shall be located in the rear yard and be hard surfaced. [image] [4] Parking shall be accessed from district, neighborhood or alley streets. [image] [5] Light level shall conform to Illumination Engineers Society of North America (IESNA) guidelines and shall be maintained from dusk to dawn. [6] Parking luminaires shall be located on the building and conform to the building lighting criteria. If additional lighting is required, freestanding light fixtures shall conform to parking lot lighting criteria. (b) Parking lot. [1] Parking lots shall not be located on the riverfront. [2] Parking lots shall not be located at Main Street intersections and at all intersecting city streets. [3] Access to parking lots shall be from district, neighborhood or alley streets. [image] [4] Parking lots shall be set back a minimum two feet and a maximum four feet on all streets except alley streets. [image] [5] Front yard setback on streets that cross the river shall be 10 feet. [6] Side yard setback shall be a maximum nine feet. [image] [7] Rear yard setback shall be a minimum of nine feet. [image] [8] Parking lots shall be hard surfaced and concrete or granite curbed. [image] [9] Parking aisles shall be oriented perpendicular to the front yard. [10] Parking lots shall be screened on city, district and neighborhood streets by a wall conforming to district building materials. [image] [11] Wall setback shall vary on street frontages every 30 feet a minimum two feet and a maximum four feet. [image] [12] The wall shall be a minimum three feet high and a maximum four feet high. [image] [13] Walls shall have pedestrian openings a minimum six feet and a maximum eight feet wide aligned with the center line of the parking aisle. Pedestrian walks, the full width of the opening, shall be hard surfaced and equal in material and pattern to the adjacent sidewalk. [image] [14] Setback shall be landscaped with one tree per 250 square feet and continuous ground cover. [image] [15] Parking lots shall be landscaped with trees and continuous ground cover in curbed islands so that the parking lot is shaded to a minimum 40% at tree maturity. [image] [16] Lighting shall conform to Illumination Engineers Society of North America (IESNA) guidelines. [17] Light fixtures shall not exceed 18 feet in height. No light shall cast upwards. [image] (2) Additional amenities. (a) Fencing/wall. [1] Fencing/wall shall conform to all street frontage setbacks. [2] Fencing shall have a maximum height of five feet. [3] Fencing shall be cast or extruded metal with a minimum transparency of 80%. [4] Gates shall be equal to fencing. [5] Walls shall have a maximum height of five feet along side and rear yards and minimum height of 1.5 feet and a maximum height of three feet along street frontage, river frontage and in plaza/forecourt. [image] [6] Walls shall conform to the district building materials. (b) Riverfront promenade/plaza. [1] Promenade shall be adjacent to the river and a minimum 12 feet wide. [image] [2] Entrances from the promenade into a plaza shall be provided and be a minimum 10 feet wide. [image] [3] Plaza shall be at grade with or above the promenade elevation. [image] [4] Promenade/plaza shall be wood, concrete or modular unit paving. [5] Promenade benches shall be provided at a minimum of one bench per 50 feet. Plaza benches shall be provided at a minimum of one bench per 35 feet of street frontage. [6] Plaza shall be landscaped with trees so that the area is shaded to a minimum 50% at tree maturity. [7] Mature plaza planting shall maintain open sight lines to the river between three feet and seven feet high. [image] [8] Plazas shall be illuminated. Lighting level shall conform to Illumination Engineers Society of North America (IESNA) guidelines. [9] Light fixtures shall not exceed 18 feet in height. No light shall be cast upwards. [image] H. [1]District plant materials. The plant materials shall conform to the Forestry Master Plan. Trees shall adhere to the following: (1) Viability: winter hardy, suitable for urban conditions of shade, air quality, desiccation and soil and space limitations as found on the particular site, resistant to blight and pests. (2) Public health and safety: thornless, no tap roots, no weak or brittle wood and no invasive weed species. (3) Design character: mature size and shape suitable for the space available, tall canopy trees for wide streets and large sites, small or columnar trees for narrow streets and small sites, multiple seasons of special interest (in leaf, in blossom, fall color, bark or branching pattern) and/or harmony with the dominant character defining tree association of the area. (4) All proposed street trees and work related to street trees shall conform to the Standards and Specifications for Street Tree and Public Tree Work.
Ask a question about Rochester law
Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.
