§ 120-72 — Cascade-Canal District
Municipal Code, City of Rochester, New York (Rochester Municipal Code, City Charter, Zoning Ordinance and Code Tables current through legislation adopted October 20, 2026 (eCode360 publication RO0104, scraped 2026-11-18)) · Rochester Zoning Ordinance § 120-72
Corpus is an independent public-information project, not the official City of Rochester website. Stable reference: corpuslaw.us/code/3ff2e80e-d520-4458-bde2-333279dbf8c9
§ 120-72: Cascade-Canal District.
A. Purpose of the district. The primary purpose of the design criteria for the Cascade-Canal District is to: (1) Preserve and enhance the existing heritage qualities of the area. (2) Allow existing warehouse and industrial style buildings to adapt to a variety of uses and function. (3) Promote a pedestrian-scaled environment and create well-defined street edges with mid-block connections. (4) Strengthen connections to Main Street and the riverfront. (5) Promote the district as an enclave which expresses an rich warehouse/industrial quality; build upon and draw from the quality of the Cascade redevelopment area. B. District boundaries and definition. The boundaries for the district were determined by identifying the extent of the warehouse/industrial character of the CCD and the practical opportunities for enhancing the area as described above. The district extends north of the Inner Loop to include Frontier Field and surrounding character lands. [image] C. Design character of the district. The design intent for this district preserves and promotes its industrial warehouse character and creates a pedestrian-scaled enclave. The design character is typified by two- to five-story, horizontal box-like buildings with flat rooflines. Facades are composed of dominant vertical columns and strong horizontal bands which divide translucent glass panels. Buildings have zero setback along street frontages to create a strong sense of enclosure and an appropriate pedestrian scale. A pedestrian-oriented alleyway system is created through the district with minimum side and rear yard setbacks. This pedestrian system links streets and allows for integrated connections to adjacent districts. D. Design Checklist. The following chart lists the design criteria and the deviations that require major site plan or minor site plan review. Applications that are within acceptable tolerances, and otherwise meet all design criteria, do not require site plan approval unless such approval is required pursuant to the other site plan thresholds as listed in § 120-191 of this chapter. Design Checklist - Cascade-Canal District Design Criteria | Major Deviation | Minor Deviation | Minor Tolerance BUILDINGS Building form and mass | X Minimum lot frontage | X Maximum building length and depth relative to block | | X | 10% Minimum and maximum building height | X Length to height ratio | | X | 20% Orientation to street frontage | X Front setback | X Side and rear yard setback | X DISTRICT CHARACTER Building maintains horizontal alignment | | X Facade composition | X Equal street frontage facades | X Vehicular entry location and garage door recessed and translucent | | X | 20% Service bay depth | | X Facade lighting | | X Facade window coverage | | X | 10% Window height to width ratio | | X | 20% Divided window openings | | X Window translucency | | X | 20% Window recess | | X | 30% Basement window width | | X Entrances on street frontage | X Entrance elevation | | X Entrance accent and translucency | | X | 20% Entrance lighting | | X Roofline | | X Roofline cornice | | X | 20% Rooftop mechanical/telecommunications equipment | | X Primary construction material of clay brick | | X | 10% Additional construction material | | X Number of colors | | X | 50% Location of refuse storage | | X Refuse storage details (enclosures, doors) | | X SIGNAGE Number of building identification signs | | X Location of building identification sign | | X Size of building identification sign | | X | 20% Building identification sign materials | | X Building identification sign luminaries | | X Building identification sign graphics | | X Building identification sign colors | | X | 30% Business signs on kiosk | | X Address sign location | | X Address sign copy raised/recessed | | X Address sign materials | | X Address sign lighting | | X Heritage sign and location | | X Heritage sign material | | X Heritage sign information | | X Heritage sign size | | X | 20% Awning locations | | X Awning width | | X | 10% Awning height | | X | 10% Awning projection | | X | 10% Awning support/attachments | | X Awning material | | X Awning color | | X | 30% Awning copy size | | X | 20% Awning lighting | | X SITE Building parking location and surfacing | | X Building rear yard parking access | | X Building rear yard parking lighting | | X Parking lot location | | X Parking lot access | | X Parking lot setback | | X Parking lot surfacing and curbing | | X Parking lot aisle orientation | | X Parking lot wall material | | X Parking lot wall height | | X Parking lot wall pedestrian openings | | X | 10% Parking lot landscaping to shade area | | X | 20% Parking lot wall columns | | X | 10% Parking lot wall relief | | X | 20% Parking lot wall column height | | X | 10% Parking lot lighting height | | X | 10% ADDITIONAL AMENITIES Drive-through setback and location | | X | 10% Wall setback | | X Wall height | | X | 10% Wall materials | | X E. Design principles for the district. The design principles for the Cascade-Canal District creates a pedestrian-scaled enclave adaptable to a wide range of uses and functions. The historic character of the district should be enhanced and preserved. Greenway linkages should be established and connections to the riverfront should be strengthened. Impacts of the Inner Loop should be alleviated through design. F. Buildings. (1) District context. (a) Building form and mass. [1] Buildings shall be horizontal and longer in length than depth along the street. (b) Lot size and coverage. [1] The minimum lot frontage shall be 40 feet. [image] [2] The maximum building length and depth shall be no more than 50% of the block length or depth. [image] (c) Height. [1] Unless otherwise noted, buildings heights shall include: [a] Main Street: N/A. [b] City street: a maximum of five stories in height to a maximum of 60 feet and a minimum of two stories. [c] District street: a maximum of five stories in height to a maximum of 60 feet and a minimum of two stories. [d] Neighborhood street: a maximum of five stories in height to a maximum of 60 feet and a minimum of two stories. [image] (d) Length to height ratio. [1] The length to height ratio shall be a maximum 2:1 and minimum 1:1 along primary street frontage. [image] (2) Orientation. (a) Buildings shall be parallel to the street frontage property line. [image] (3) Setback. (a) Unless otherwise noted, front yard setbacks shall include: [1] Main Street: N/A. [2] City street: zero feet. [3] District street: zero feet. [4] Neighborhood street: zero feet. [image] (b) Side and rear yard setback shall be a minimum of 7.5 feet and a maximum nine feet. [image] (4) District character. (a) Facade composition. [1] Buildings shall maintain the alignment of horizontal elements of adjacent existing buildings. [image] [2] The building facade shall be composed to exhibit vertical columns 18 feet to 24 feet on center. Columns shall be two feet to three feet wide and create a relief from the plane of the facade. [image] [3] All facades fronting a street shall conform to the district criteria and be equal. [image] [4] One vehicular entrance is permitted on street frontages provided it is located between columns and is enclosed with a garage door. The garage door shall be recessed from the plane of the facade between 1.5 feet and three feet and shall be a minimum of 30% translucent. [image] [5] The depth of any service bay shall accommodate total vehicle length so as not to interrupt pedestrian circulation on the sidewalk. [image] [6] Facade lighting shall be wall-mounted luminaires historic in character and shall be mounted no higher than the top of the first floor and shall illuminate the sidewalk. No light shall cast upwards. [image] [7] Facade lighting shall conform to Illumination Engineers Society of North America (IESNA) guidelines. No floodlighting is permitted. (b) Window. [1] All street facades shall be a minimum 50% and a maximum 70% window coverage. [image] [2] All alley street facades shall be a minimum 25% window coverage. [image] [3] The window height to width ratio shall be 1:1 to 1:1.5 and shall exhibit regular fenestration. [image] [4] Window openings shall be divided with mullions; muntins are permitted. [image] [5] Windows shall be translucent and shall permit views 10 feet into the building when standing five feet away from window. [image] [6] Windows shall be recessed three inches to six inches from the facade. [image] [7] Basement windows shall maintain the same width as windows directly above. [image] (c) Entrance. [1] Entrance into the buildings shall be provided on city, district and neighborhood street frontages. [image] [2] Entrances shall be flush with the sidewalk; changes in elevation shall be made internally. [image] [3] Entrances shall be clearly accented and 60% translucent. [image] [4] Entrances shall be illuminated and shall conform to facade lighting. [image] (d) Roofline. [1] Rooflines shall be flat. [image] [2] Rooflines shall be delineated with simplified crown cornices a minimum two feet wide to a maximum three feet wide. [image] [3] Rooftop mechanical equipment shall be concealed so as not to be visible from the street. [image] (e) Material and color. [1] Non-glass surfaces on street facades shall be a minimum of 55% to 65% clay brick. [image] [2] In addition to the windows and clay brick, one additional construction material may be used on the street facade including natural stone, stucco [exterior insulation finish system (EIFS)] or decorative concrete. [image] [3] Excluding windows, a maximum of two colors shall be permitted. (f) Refuse storage. [1] Excluding alley streets, refuse storage shall not be located on a street frontage and shall not be visible from the street. [2] Refuse storage areas shall conform to one of the following: [a] If a loading dock/service bay or vehicular garage is part of the building, refuse storage shall be contained within this area. [image] [b] If there is no loading dock/service bay or vehicular garage, refuse storage shall be located within the building, accessible from the exterior and enclosed with a solid metal door. The doors shall be integrated into the facade pattern in a manner consistent with the character of the building. [image] [c] If not located within the building, refuse storage shall be located within a concealed enclosure that includes solid metal doors, is integral to the building, consists of the same materials as the building and is located at the rear of the building. [image] (5) Signage. (a) Building identification signage. [1] One sign shall be allowed on each street frontage. [image] [2] Signs shall not be placed higher than the top of the first floor. [image] [3] Signs shall be integrated into the facade pattern between columns and shall be located above or adjacent to primary building entrances; signs shall be horizontal or vertical and flush mounted. [image] [4] Signs shall not exceed 30 square feet and shall have a maximum width of three feet. [image] [5] Sign materials shall include any of the district building materials, wood and metal. [6] Sign luminaires shall conform to the facade lighting. [7] Sign graphics shall be raised or recessed copy. [8] Signs shall include no more than three colors. [9] Signs may be painted onto facades fronting alley streets. (b) Business signage. [1] Signage shall be placed on a common kiosk at each street building entrance and shall conform to street criteria. (c) Address signage. [1] Signs shall be located at the primary building entrance no higher than top of the first floor. [image] [2] Sign graphics shall be raised or recessed copy and shall be a minimum of two inches and a maximum nine inches in height. [image] [3] Sign materials shall include any of the district building materials and metal. [4] Building lighting shall illuminate the sign. [image] (d) Heritage signage. [1] One sign shall be placed on the primary frontage of each building and shall be located no higher than five feet above finished grade. [image] [2] Signs shall be face mounted to the building facade. [3] Signs shall be made of metal. [4] Signs shall include, at a minimum, the date of construction. [5] The maximum sign area shall be 1.5 square feet. [image] (e) Awning. [1] Awnings shall be permitted at building entrances. [image] [2] The maximum width shall be two times the width of the entrance opening. [image] [3] Awnings shall be a maximum nine feet above the entrance elevation. [image] [4] Awnings shall project no more than half the width of the sidewalk. [image] [5] Awning support shall include building attachments only. [image] [6] Awnings shall be made of flexible woven, natural or synthetic material. [7] Awning fabric shall include no more than three colors. [8] Awning signage copy shall include only building identification or address located on the valance and shall be a maximum eight inches in height. [image] [9] Awnings shall only be illuminated by building lighting. G. Site. (1) Parking. (a) Building parking. [1] Building parking shall not be located at intersecting city streets. [2] Building parking shall be located in the rear yard and be hard surfaced. [image] [3] Parking shall be accessed from alley streets. [image] [4] Lighting shall conform to Illumination Engineers Society of North America (IESNA) guidelines. [5] Parking luminaires shall be located on the building and conform to the building lighting criteria. If additional lighting is required, freestanding light fixtures shall conform to parking lot lighting criteria. (b) Parking lot. [1] Parking lots shall not be located at intersecting city streets. [2] Access to parking lots shall be from alley streets. [image] [3] Parking lots shall have setbacks to accommodate the required wall on all streets except alley streets. [image] [4] Side and rear yard setback shall be a minimum 7.5 feet and a maximum nine feet. [image] [5] Parking lots shall be hard surfaced and concrete or granite curbed. [6] Parking aisles shall be oriented perpendicular to the front yard. [image] [7] Parking lots shall be screened on city, district and neighborhood streets by a wall conforming to district building materials. [image] [8] The wall shall be a minimum three feet high and a maximum four feet high. [image] [9] Walls shall have pedestrian openings eight feet to 10 feet wide aligned with the center line of the parking aisles. Pedestrian walks, the full width of the opening, shall be a hard surfaced and equal in material and pattern to the adjacent sidewalk. [image] [10] Parking lots shall be landscaped with trees and continuous ground cover in curbed islands so that the parking lot is shaded to a minimum 40% at tree maturity. [image] [11] Columns shall be expressed in the wall 18 feet to 24 feet on center. [image] [12] Wall columns shall create a relief from the plane of the wall a minimum four inches. [image] [13] Column width shall be 16 inches to 24 inches. [image] [14] Lighting shall conform to Illumination Engineers Society of North America (IESNA) guidelines and shall be maintained from dusk to dawn. [15] Light fixtures shall not exceed 18 feet in height. No light shall be cast upwards. [image] (2) Additional amenities. (a) Drive-through. [1] Drive-through shall be located on an alley street and set back 60 feet from the front yard. [image] [2] Drive-through shall be integral to the building. (b) Wall. [1] Walls shall conform to all building setbacks. [2] Walls shall have a maximum height of five feet along side and rear yard and a minimum height of 1.5 feet and a maximum height of three feet along street frontages. [image] [3] Walls shall conform to the district building materials. H. [1]District plant materials. The plant materials shall conform to the Forestry Master Plan. Trees shall adhere to the following: (1) Viability: winter hardy, suitable for urban conditions of shade, air quality, desiccation and soil and space limitations as found on the particular site, resistant to blight and pests. (2) Public health and safety: thornless, no tap roots, no weak or brittle wood and no invasive weed species. (3) Design character: mature size and shape suitable for the space available, tall canopy trees for wide streets and large sites, small or columnar trees for narrow streets and small sites, multiple seasons of special interest (in leaf, in blossom, fall color, bark or branching pattern) and/or harmony with the dominant character defining tree association of the area. (4) All proposed street trees and work related to street trees shall conform to the Standards and Specifications for Street Tree and Public Tree Work.
Ask a question about Rochester law
Corpus searches the Rochester sections it holds and shows the ones that match, with their citations. Free, no sign-in.
