Sec. 23-27. - Regulations for stokers (bituminous).

The following regulations shall apply to stokers (bituminous): A. Coal-burning-rate load determination. In the determination of loads for the purpose of selecting coal burning rates of stokers, all heat dissipating devices shall be converted to equivalent direct radiation, btu per hour, or square inches of leader pipe area for gravity warm air systems. B. Measurements—General specifications. (1) One square inch of leader pipe area shall be equivalent to one hundred thirty-six (136) btu per hour. (2) One cubic foot of combustion space will be required for each four (4) pounds of coal burned per hour in all domestic or semi-industrial installations. (3) Five (5) pounds of coal per hour per cubic foot of combustion space will be allowed if overfire air is used. C. Clear height—Underfed stockers. (1) When no obstruction exists over the hearth nor within eighteen (18) inches horizontally in the direction of gas flow from the nearest margin of the tuyeres, the clear height shall be taken to the crown sheet or shell at the center of the furnace. (2) All the tubes of down draft grates in steel boilers shall be removed, except that two (2) tubes on each side of the furnace may be left in place, otherwise, the clear height shall be taken to the bottom of the water grate. (3) Drums in steel down draft boilers from which the tubes have been removed shall not be considered as obstructions; provided that there is an open space across the furnace between the drum and the crown sheet or shell. (4) The clear height shall be measured to the bottom of the water grates for cast iron down draft boilers. (5) Drop arches: Boilers having a drop arch from the top of the furnace and a distance less than eighteen (18) inches in a horizontal direction of gas flow from the nearest margin of the tuyeres shall have a clear height from the top of the tuyeres to the drop arch, which shall not be less than sixty-six and two-thirds (66 2/3) percent of the required clear height in the furnace. (6) Stokers shall be installed with clear heights not less than those shown in the following table. Measurements are from the top of the tuyeres to the center of the crown sheet. D. Table of clear heights. Maximum Burningc;Rate Per Hour | Lbs. per hour Requirements Sq. ft. of Steam Radiation | Minimum Clear Height to Crown-In | Minimum Clear Height to Drop Arch 20 | 444 | 18 | 12 25 | 555 | 19 | 12½ 30 | 666 | 20 | 13½ 35 | 777 | 21½ | 14½ 40 | 888 | 22½ | 15 45 | 1,000 | 23 | 15½ 50 | 1,001 | 24 | 16 60 | 1,200 | 25½ | 17 70 | 1,400 | 26½ | 17½ 75 | 1,500 | 27 | 18 80 | 1,600 | 27½ | 18 90 | 1,800 | 28 | 18½ 100 | 2,000 | 29 | 19½ 125 | 2,500 | 30 | 20 150 | 3,000 | 31 | 20½ 175 | 3,500 | 32 | 21 200 | 4,000 | 33 | 22 250 | 5,000 | 34½ | 23 300 | 6,000 | 36 | 24 350 | 7,000 | 37 | 24½ 400 | 8,000 | 39 | 26 450 | 9,000 | 40 | 27 500 | 10,000 | 41½ | 28 600 | 12,000 | 44 | 29 650 | 13,000 | 45 | 30 700 | 14,000 | 46 | 30½ 750 | 15,000 | 47½ | 31½ 800 | 16,000 | 48 | 32 1,000 | 20,000 | 51½ | 34 1,250 | 25,000 | 54 | 36 1,500 | 30,000 | 56 | 37½ E. Sizing stokers—Bituminous stokers—Steam and hot water heating systems. (1) When the total net load is less than the certified hand fired rating of the boiler and greater than fifty (50) percent thereof, the stoker shall be of sufficient size to burn four and one-half (4½) or five (5) pounds of coal per hour (see paragraph "(4)" of this subdivision "E") for each one hundred (100) square feet of the boiler's certified hand fired rating. (2) When the total net load is less than fifty (50) percent of the certified hand fired rating, the stoker shall be of sufficient size to meet the net load plus seventy (70) percent of the difference between the net load and the certified hand fired rating of the boiler. The stoker shall burn four and one-half (4½) or five (5) pounds of coal per hour (see paragraph "(4)" of this subdivision "E") for each one hundred (100) square feet of load as obtained. (3) When the net load exceeds the certified hand fired rating, and is less than one hundred twenty-five (125) percent thereof, the stoker shall be of sufficient size to burn four and one-half (4½) or five (5) pounds of coal per hour (see paragraph "(4)" of this subdivision "E") for each one hundred (100) square feet of net load. Permits will not be issued for stoker installations in standard or conventional heating boilers where the net load exceeds one hundred twenty-five (125) percent of the certified hand fired rating. (4) Domestic stokers shall be sized on the basis of four and one-half (4½) pounds of coal per one hundred (100) square feet of steam radiation for low pressure heating installations of not to exceed one thousand (1,000) square feet of steam radiation as determined by paragraphs "(1)," "(2)" and "(3)" of this subdivision "E." Stokers shall be sized on the basis of five (5) pounds of coal per hour per one hundred (100) square feet of steam radiation for all heating installations of over one thousand (1,000) square feet of steam radiation as determined by paragraphs "(1)," "(2)" and "(3)" of this subdivision "E." (5) If the boiler is of a type designed exclusively for mechanical firing and has no hand fired rating, the stoker shall be sized on the total net load, provided this load is between eighty (80) percent and one hundred (100) percent of the mechanically fired rating, and on eighty (80) percent of the mechanically fired rating if the total net load is less than this amount. Permits will not be issued for the installation of stokers in boilers of this type if the total net load exceeds the mechanically fired rating. F. Sizing stokers—Bituminous stokers—Warm air heating systems. (1) Stoker sizes for installation in warm air furnaces shall be determined as follows: (a) Loads not greater than one thousand seven hundred sixty-five (1,765) square inches of leader pipe area or 240,000 btu at registers. Gravity warm air: Stoker pounds per hour = 2.92 L Stoker pounds per hour = 0.214 H Mechanical warm air: Stoker pounds per hour = 0.189 H (b) Loads greater than one thousand seven hundred sixty-five (1,765) square inches of leader pipe area or 240,000 btu at registers. Gravity warm air: Stoker pounds per hour = 3.22 L Stoker pounds per hour = 0.236 H Mechanical warm air: Stoker pounds per hour = 0.208 H In the above formulae "L" is the total load in 100 square inches of leader pipe area and "H" is the total load in 1,000 btu's determined as indicated in paragraph "(2)" of this subdivision "F." (2) The total load shall be determined as follows: (a) If the requirements of the building to be heated, plus any indirect load such as domestic hot water, are equal to or greater than eighty-five (85) percent of the hand fired rating of the furnace, these requirements shall be used for "L" or "H." (b) If the requirements as computed above are less than eighty-five (85) percent of the hand fired rating of the furnace, "H" and "L" shall be taken to be eighty-five (85) percent of the hand fired rating of the furnace. (3) Permits will not be issued for the installation of mechanical firing in existing warm air heating systems in which the requirements of the building as computed above are greater than the mechanically fired rating of the furnace or greater than the capacity of the existing individual or trunk line supply system. G. Off period smoke prevention. (1) Dead plate type stokers having a burning rate of one hundred (100) pounds of coal per hour or over shall not be installed without some approved method or device for eliminating off period smoke. All stokers over two hundred (200) pounds per hour shall be so equipped. (2) Applications for such installations shall be submitted on the regular application blank, supplied by the division, accompanied by a supplemental application which shall describe in detail the method or devices used for eliminating off period smoke. H. Special boilers and furnaces. (1) The following equipment shall be installed only on the condition that low volatile coal is used, unless equipped with a mechanical fuel burning device and furnace especially designed for smokeless combustion of high volatile coal: Vertical Boilers, Water Tube Boilers, Portable Boilers, Contractor's Equipment and Incinerators. All such equipment shall be designed with special attention given to elimination of causes or possibilities of emission of dense smoke. Installation of same shall include all servicing necessary for the proper regulation of smoke to comply with all provisions of this chapter. (2) Steel boilers: Applications for permits involving steel boilers which are not listed and rated in manufacturers' catalogues must show the diameter of the boiler shall and the number, diameter and length of the boiler tubes. A description such as "H.R.T.—150 hp" or "30 hp vertical tubular" will not be accepted unless the above data are also given. (3) Combustion arches: A combustion arch is a long rear arch extending forward from the bridge wall over the stoker. Stokers equipped with combustion arches shall have a clear passage between the arch and the crown sheet equal in area to at least one hundred twenty-five (125) percent of the entrance area of the flues or tubes. Such arches are not subject to the clear height restrictions, but the combustion volume allowed shall be that over the hearth only, figuring the height from grate to crown. I. General. (1) Controls: The type and installation of stoker controls shall be in accordance with all ordinances of the city applying thereto. All bituminous stokers installed in the heating plants of commercial or industrial buildings, including apartments housing three (3) or more families, shall be equipped with a control or system of controls by means of which fire may be maintained in the fuel bed of the stoker for extended idle periods (such as overnight and week-end banking) and which will automatically start the stoker at any predetermined time without manual aid on the part of the attendant. (2) Ledge distance: A minimum ledge distance of four (4) inches from inner edge of tuyere is required on all sides of a standard underfeed retort stoker, provided that this ledge is in a horizontal plane or sloping downward towards the furnace wall. (3) Chimney size: The chimney shall be of such cross sectional area and height as to produce a minimum draft of 0.04 inches of water above the fuel bed when the equipment is operating at rated load. Manufacturers' ratings may be used when available. (4) Fly ash collectors: All boilers, furnaces or combustion devices for the burning of fuel, fully or partly in suspension, shall be equipped with an approved fly ash collector. (5) Ventilation: Plans and specifications submitted with each installation shall also contain a statement of the amount and kind of fuel or refuse proposed to be used. Said plans and specifications shall also show that the room or premises, in which fuel or refuse burning plants shall be located, is provided with doors, windows, air shafts, fans and other means of ventilation sufficient to provide that the atmosphere of any such room, basement or other part of the building wherein such fuel or refuse burning apparatus may be located, may be changed every ten (10) minutes. (6) Cleanout doors: Cleanout doors shall be of sufficient size and so located that ash and clinker can be easily removed. It is recommended that on all stoker installations, a cleanout door be provided in the breeching and at the base of the stack. (7) Fuel recommendations: The installer of fuel burning equipment shall specify on the application for permit the kind, type or size of fuel recommended for use with such fuel burning equipment.

Ask a question about Syracuse law

Corpus searches the Syracuse sections it holds and shows the ones that match, with their citations. Free, no sign-in.