Sec. 23-29. - Regulations for over-fire air systems.

The regulations in this section shall apply to over-fire air systems. These regulations are intended to standardize the installation of over-fire air systems which are used to control the emission of off period smoke. When so used, it is necessary that he system be in operation only during the stoker off periods for a sufficient length of time to prevent smoking. Systems designed and installed according to these regulations may also be used to provide over-fire air for stoker installations in which the furnace volume is limited and it is necessary or desirable to take advantage of subdivision B(3) of section 23-27 (stoker regulations). In installations of this type, the over-fire air system must operate at all times while the stoker is running. A. Number and size of jets. The minimum number and size of jets shall be determined from the following table. The installer may employ more or larger jets if desired. Jet sizes shown in the table are nominal diameters of standard iron pipe. Stoker Size Lbs./Hr. | Minimum Number and Size of Jets 100— 300 | 3—¾" 301— 500 | 4—¾" 501— 800 | 4—1" 801—1,000 | 5—1" or 4—1¼" 1,001—1,250 | 5—1¼" or 4—1½" 1,251—1,500 | 5—1½" or 6—1¼" B. Spacing of jets. Jets which are directed from front to rear of firebox, or vice versa, shall be located symetrically with respect to a vertical plane drawn longitudinally through the center of the stoker retort. Jets located six (6) inches or less from the side wall of the boiler firebox shall be directed away from the wall at an angle of six (6) to eight (8) degrees. C. Height of jets above tuyeres. The height of the port openings above the top of the stoker tuyeres shall be not less than sixty (60) percent of the required stoker clear height as specified in subdivision D of section 23-27. D. Port openings. Port sizes specified in subdivision A hereof and plate I refer to I.P. sizes. Iron pipe ports shall be reamed at both ends. E. Duct work. Ducts connecting the fan with the jet header shall be smooth iron or steel pipe having a cross sectional area not less than that of the outlet of the blower housing. All pipe ends shall be reamed. It is recommended that long radius ells be used where bends in the duct line are necessary and all other precautions be employed to keep friction loss at a minimum. A capped one-eighth inch I.P. connection to the header, or a tapped one-eighth inch opening with plug in the duct line as close to the header as possible, shall be provided in order that the static pressure may be checked after installation. Pressure loss in the duct line will be computed from Plate II as explained in subdivision F(2) of this section. To find the equivalent length of duct for this purpose, proceed as follows: Determine the actual length of straight duct without fittings between the fan and the header. To this add the lengths shown in the following table for each fitting in the line: Pipe Size | Valves | Fittings* 2" | 7 ft. | 4½ ft. 3" | 13 ft. | 8 ft. 4" | 20 ft. | 13 ft. 5" | 28 ft. | 18½ ft. 6" | 36 ft. | 24 ft. 8" | 53 ft. | 35 ft. *Equivalent lengths given under "Fittings" may be used for standard ells, tees and crosses. For long-radius and forty-five (45) degree ells, use one-half of these amounts. F. Capacity of fan or blower. (1) The minimum required capacity of the fan in cubic feet per minute (cfm) and the static pressure in inches of water (sp) required at the jets shall be determined from Plate I as follows: Take two-thirds of the length of the firebox and locate this dimension on the bottom horizontal line. Draw a line vertically upward until it intersects the sloping straight line which represents the size of air ports to be used. The static pressure required at the jets will be read from this point by its relation to the curved static pressure lines. From the point of intersection, draw a line horizontally to the left and read the cfm per port on the vertical scale. Multiply this figure by the number of ports to be employed to give the required cfm of the blower. (2) To obtain the static pressure required at the fan or blower, add to the static pressure at the jets (found in paragraph "(1)" above) the pressure loss in the duct line between the fan and the header determined from Plate II as follows: On the left hand vertical scale, locate the cfm of the fan (determined in paragraph "(1)" above) and draw a line horizontally to the right until it intersects the sloping line representing the size of the duct pipe. From this point, extend a line vertically downward and read the pressure loss per hundred feet of pipe on the bottom scale. Multiply this figure by the equivalent length of duct (as determined by subdivision "E" hereof) and divide by one hundred (100).

Ask a question about Syracuse law

Corpus searches the Syracuse sections it holds and shows the ones that match, with their citations. Free, no sign-in.