§ 9-4-6 — Final construction plan
Municipal Code of the City of White Plains, New York (Codified through Ordinance of October 5, 2026. (Supp. No. 79, Update 2)) · White Plains City Code § 9-4-6
Corpus is an independent public-information project, not the official City of White Plains website. Stable reference: corpuslaw.us/code/ec3371f3-a46c-4b0d-aa90-70d7f1f8086a
Sec. 9-4-6. - Final construction plan.
The applicant shall submit one (1) suitable mylar transparency and/or equivalent reproducible and two (2) lithoprints on cloth showing street[s], structures and all other proposed improvements at an overall scale not to exceed forty (40) feet to one (1) inch, and containing appropriately scaled exploded detail drawings where necessary shall be filed with the board and shall show: 6.1 Map title and other requirements: The construction plan shall show the title by which the proposed subdivision is to be recorded, the name(s) of the owner(s) and engineer(s) and the New York State professional engineer's registration number, the date of submittal, legend, north point, and graphic scale. 6.2 Location of monuments: The location and coordinates of all monuments shall be shown with said coordinates referenced to the nearest approved base line of the Westchester County Control System, or City of White Plains datum, as shall be directed by the commissioner of public works. In the absence of such base line within one thousand (1,000) feet of the proposed subdivision, the method of referencing shall be determined by the commissioner of public works. 6.3 General base data: The location of proposed property lines, streets, pavements, sidewalks, easements, building lines, alleys, cul-de-sacs, parks and other open spaces, sanitary sewer system, water supply system and collection basins, and means of discharging surface drainage shall be shown. 6.4 Base data—Streets: The proposed street layout, location and type of sidewalks, final street grades at the centerline, street lighting standards locations, street name sign and utility pole location, location and species of street trees, location of curbs, gutters, catch basins, manholes, sanitary sewers, storm drains, water mains, fire alarm ducts, and their sizes and types, within the rights-of-way shall be shown. In addition, a typical cross-section showing all details of the width and depth of pavements and sub-base, and any cut and fill between property lines shall be shown. Said section drawing shall be made at a minimum scale of not more than one (1) inch equals four (4) feet. 6.5 Street details: The subdivider shall submit as part of, or appended to the construction plans, profiles of proposed streets or other public ways on a suitable mylar transparency and/or equivalent reproducible and two (2) lithoprints on cloth. Said profiles shall show the centerlines and both property lines (right-of-way lines) elevations or profiles, proposed curb grades and point of intersection, point of curvature, point of tangency, and the breaks in grade, stations and elevations for a pavement at least thirty (30) feet wide, the proposed sewer, drain, water main and underground utility elevations; the stationing, elevation, etc., of all existing monuments, water tables at buildings, drains, sewers, culverts, hydrants and manholes (both rim and invert), at a scale of one (1) inch equals four (4) feet vertical and one (1) inch equals twenty (20) feet horizontal. All stationing shall show accurate centerline distances. Elevations of the ground surfaces shall be shown to the nearest one-tenth of a foot while all fixed points shall be shown to the nearest one-hundredth of a foot, using city datum. 6.6 Construction standards: In developing the construction plan, the subdivider shall adhere to the following construction standards: For purposes of obtaining proper procedures of subdivision review, it is requested that the subdivider submit two (2) blue line paper prints of the construction plans to the commissioner of public works in order to establish conformance to all requirements of this section prior to the submittal of the construction plan. 6.6-1 Specifications approved by commissioner of public works: All material, structures, manholes, pipe types and sizes, depths and grades, design and workmanship must meet specifications established below by the commissioner of public works. 6.6-2 Municipal utilities: All municipal utilities proposed and/or constructed in any existing or proposed right-of-way or utility easement to be dedicated to the city shall be subject to inspection and approval during construction by the commissioner of public works. Final approval and acceptance of such utilities shall be exclusively within the jurisdiction of the department of public works. 6.6-3 Street grading: All streets to be graded from property line to approved final grade and cross-section as approved by the commissioner of public works. 6.6-4 Curbs: Curbs shall be required in all streets and shall be of fieldstone or granite, meeting the approved specifications of the commissioner of public works. 6.6-5 Sidewalks: Sidewalks shall be provided where required by the planning board. Sidewalk design and construction shall be as approved by the commissioner of public works. 6.6-6 Street pavement width: Street pavement shall be at least thirty (30) feet (which could provide for two-way traffic and parking on one side of the street) except where a greater width is determined by the commissioner of public works and the deputy commissioner of parking responsible for transportation engineering. 6.6-7 Pavement: Pavement shall be three-inch hot-mix bituminous surfacing on five-inch plant mix macadam base, or eight-inch reinforced concrete pavement, all measurements being compacted measure. (See 9.3-1. [9-4-11.3-1].) 6.6-8 Sewers: Sewers shall meet the standards and design requirements of the commissioner of public works and the New York State Department of Health. (See page [section] 9.3. [9-4-11.3].) 6.6-9 Storm drains: Storm drains shall meet the standards and design requirements of the commissioner of public works. (See 9.3. [9-4-11.3].) 6.6-10 Water mains: Water mains shall meet the standards and design requirements of the commissioner of public works and the New York State department of health. Water mains shall be not less than eight-inch ductile iron, except where larger pipe may be required to provide an adequate distribution system as determined by the commissioner of public works. The top of the pipe to be at least four and one-half (4½) feet below the top of the pavement or other ground, so as to provide a maximum cover of four and one-half (4½) feet between finished grade and top of pipe. 6.6-11 Fire hydrants: Fire hydrants shall be provided for purposes of fire protection and shall be spaced not more than three hundred fifty (350) feet apart and near property corners. Hydrant types and connections shall be the approved standard of the department of public works. All standards shall be as approved by the commissioner of public works and all hydrants shall be tested after placement. 6.6-12 Gas mains: Gas mains shall be at a location and depth approved by the commissioner of public works and in all cases shall be laid in a separate trench which shall not be used by any other type of conduit or pipe. 6.6-13 Street lighting: Poles, brackets and lights shall be of a type, size and location determined by the commissioner of public works. Light installation shall be complete and fully energized. 6.6-14 Electrical, telephone, cable TV and other communications technology services: Shall hereafter be placed underground where required by the commissioner of public works. Said underground utilities to be of approved trench-lay cable and conduit per specifications as established by the commissioner of public works in conjunction with accepted engineering practice standards of the appropriate power, telephone, cable TV and other communications technology utilities. 6.6-15 Street trees: Shall be of Pin Oak, Norway Maple, Crimson King, Redspire Pear or other species approved by the commissioner of public works. Minimum caliper shall be two and one half (2½) to three (3) inches. 6.6-16 Fire alarm system: Cable ducts shall be provided for fire alarm systems according to the standards and specifications of the commissioners of public safety and public works. Fire alarm systems may not be required, in whole or in part, where deemed unnecessary by the commissioners of public safety and public works. If required, signal boxes shall be of standard approved type as determined by the commissioner;i§ .....i; of public safety and public works. 6.6-17 Street name signs: Shall be furnished and installed by the subdivider according to the standards and specifications of the commissioner of public works and/or the deputy commissioner of parking responsible for transportation engineering, in regard to number, size, location, height and type of sign. 6.6-18 Street names: Shall be subject to approval by the commissioner of public safety and the commissioner of public works. In choosing street names, the proposed name shall avoid potential confusion with existing street names. 6.6-19 Traffic controls: Shall be determined by the department of parking, and any modifications of intersection design, curb cuts, etc., based on sight distance hazards or like traffic safety engineering concerns, shall be made by the subdivider. Traffic control devices and signs as required, once installed by the subdivider, shall be the responsibility of the city only after final acceptance of the completed street. All corners shall be subject to meeting the minimum standards of the sight module requirements established by the zoning ordinance of the city.
(L.L. No. 4-2012, § 2)
Ask a question about White Plains law
Corpus searches the White Plains sections it holds and shows the ones that match, with their citations. Free, no sign-in.
