For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 1105.1203 — General requirements

Toledo Municipal Code (2026 S-105: complete to June 30, 2026) · Toledo Municipal Code § 1105.1203

Corpus is an independent public-information project, not the official City of Toledo website. Stable reference: corpuslaw.us/code/1ac2e8f0-4887-4ab0-bb22-ca9d1f757801

1105.1203 General requirements.

A. Meteorological Towers shall not be allowed for time periods in excess of twelve (12) months and shall be removed prior to the installation of the wind energy system for which they are measuring. A request to install a meteorological tower shall be included in the application to install either a Micro Wind System or a Small Wind Energy System. B. Building-mounted micro wind systems shall be regulated by applicable building and electrical codes, and system height shall not exceed the maximum permitted building height by more than thirty (30%) percent. Any building mounted micro wind system that exceeds the maximum permitted building height by more than thirty (30%) percent shall be subject to review by the Toledo City Plan Commission as a major site plan review unless a Special Use Permit (SUP) is required. C. Maximum System Height - Freestanding Small Wind Energy Systems shall not exceed the maximum height requirement in residentially zoned districts, subject to TMC 1106.0100 - Intensity and Dimensional Standards. These systems shall not exceed sixty-five (65) feet for commercial and one hundred and twenty (120') feet for industrial and institutional zoned districts. A SUP is required in an IC District if the system height exceeds the maximum height as shown on the approved Master Plan. In multi- dwelling residential, commercial and industrial zoning districts, a wind energy system that exceeds these height limits may be allowed with a SUP. D. Setbacks - Small Wind Energy Systems shall be set back from all property lines a distance equal to one hundred twenty (120%) percent of the height of the structure including the blades to maintain an adequate fall zone. Micro Wind Energy Systems shall be set back from all property lines a distance equal to fifty (50%) percent of height of the structure including the blades to maintain an adequate fall zone. No part of the Small Wind Energy System or micro wind system structure, including, but not limited to, guy wire anchors, may extend closer than ten feet (10') to the property line. E. Sound - Micro Wind Systems and Small Wind Energy Systems shall not exceed thirty (30) dbA, measured from the closest property line (four feet (4') or five feet (5') above grade) in residentially zoning district and fifty-five (55) dbA in non-residential zoned district and enforced by either Toledo Police Department per TMC 507 or Environmental Services. The facility owner and operator shall make reasonable efforts to minimize shadow flicker to any proposed wind energy system. F. Turbine Clearance - No portion of any turbine shall extend within twenty feet (20') of the ground, overhead utility lines, parking areas, driveways and sidewalks. G. Automatic Over-Speed Controls - All Micro Wind Systems and Small Wind Energy Systems shall be equipped with manual (electronic or mechanical) and automatic over-speed controls to limit the blade rotation speed to within the design limits of the Micro Wind System or Small Wind Energy System. H. Tower color - Tower colors shall be off-white, gray, or neutral subdued tones, such as earth tones of green or brown. Towers shall not be finished in bright or vivid colors, nor shall the tower be used for advertising of any kind. I. Lighting - Micro Wind Systems and Small Wind Energy Systems shall not be artificially lighted, except as required by the FAA. J. Climb prevention - Small Wind Energy Systems shall not be climbable up to fifteen feet (15') above the ground surface. K. Wind Energy Systems on residentially zoned properties shall have a nameplate capacity of ten (10) kilowatts or less. In multi-dwelling residential, commercial, industrial, and institutional campus zoning districts, a wind energy system with more than ten (10) kilowatts may be allowed with a SUP. L. Wind Energy Systems shall not be permitted in any front yard. M. No more than one (1) Wind Energy System shall be permitted per parcel. More than one (1) wind energy system may be allowed on a parcel in an IC District if shown in the approved Master Plan or with a SUP, and in multi-dwelling residential, commercial and industrial zoning districts with a SUP. N. Wind energy system proposed for location in a designated historic district shall be subject to TMC 1103.0300 and TMC 1111.1109. (Ord. 96-10. Passed 3-2-10; Ord. 164-11. Passed 4-5-11.)

Ask a question about Toledo law

Corpus searches the Toledo sections it holds and shows the ones that match, with their citations. Free, no sign-in.