1105.1204 Application requirements.

Application to construct new or alter an existing wind energy system facility shall be submitted to the Division of Building Inspection. The Division of Building Inspection and Plan Commission staff shall determine if the application conforms to the requirements of this ordinance and other applicable regulations of the City of Toledo. Application: The following materials shall be provided as part of the application process: A. Property lines and dimensions of the applicant's property. B. Location, dimensions, and use of existing structures on the property. C. Location of the proposed small wind energy system, foundations, guy anchors and associated equipment. D. Setback requirements as outlined in this ordinance. E. The right-of-way of any public road that is contiguous with the property. F. Any overhead utility lines. G. Small wind energy system specifications, including manufacturer, model, rotor diameter, tower height, tower type, and kilowatt rating. H. Foundation and anchoring details sealed by an architect or engineer registered in the State of Ohio. I. Small wind energy systems that will be connected to the power grid shall include a copy of the application for interconnection with their electric utility provider and application for a City of Toledo electrical permit. J. Sound level analysis prepared by the wind generator manufacturer or qualified engineer. K. A maintenance schedule and a clear fall zone shall be shown on the site plan. L. Certification that the design is in compliance with the current National Electric Code and local electrical code. Building permit applications for Micro Wind Systems and Small Wind Energy Systems shall be accompanied by a line drawing of the electrical components in sufficient detail to allow for a determination that the manner of the installation conforms to the National Electrical Code and local electrical codes. M. Evidence satisfactory to the Director of the Toledo-Lucas County Plan Commissions that the proposed system meets the following standards: 1. That the Micro Wind System or Small Wind Energy System is Under Writers Laboratory (UL) listed, and/or meets the Institute of Electrical and Electronic Engineers (IEEE) standards, or other Nationally Recognized Testing Lab (NRTL); 2. Information demonstrating that the wind turbine is approved under an emerging technology program, such as International Electrotechnical Commission (IEC) or any other small wind certification program recognized by the American Wind Energy Association (AWEA) or the U.S. Department of Energy. Non-certified wind turbines must submit a description of the safety features of the turbine prepared by a professional mechanical engineer. N. Equipment Replacement - Any major replacement such as the turbine blades, generator, main gear-box or the entire wind energy system shall comply with the current ordinance. (Ord. 96-10. Passed 3-2-10.)

Ask a question about Toledo law

Corpus searches the Toledo sections it holds and shows the ones that match, with their citations. Free, no sign-in.