§ 17.04.560 — Access Standards for Security Gates

Code of Ordinances of the City of Edmond, Oklahoma (Codified through Ordinance No. 4097, enacted August 10, 2026 (Supp. No. 40)) · Edmond Code of Ordinances tit. 17, § 17.04.560

Corpus is an independent public-information project, not the official City of Edmond website. Stable reference: corpuslaw.us/code/7ad1e704-1d8f-45c4-920c-8084cc8fd48c

17.04.560 - Access Standards for Security Gates.

IFC Section 503.6 is hereby amended to read as follows: 503.6 Security Gates. The installation of security gates across fire apparatus access roads or single-family residential property drives shall be approved by the fire code official and meet the following: 1. A permit shall be obtained for installation of all automatic gates. Plans for automatic gates shall be reviewed and approved by the fire code official and a permit issued before installation begins. All gate installations shall be inspected and tested by the fire code official before they are put into operation. 2. No public street shall be obstructed. All preliminary or final plats submitted with private streets and gated access shall be subject to approval of the Planning Commission and/or City Council. 3. The gate shall be located a sufficient distance from a public street to allow four cars to line up at the gate without interfering with vehicles utilizing the public street. The minimum acceptable distance from the gate opening device or pedestal to the public street shall be no less than 80 feet (24 384 mm). Exception: Gates installed on single-family residential property. 4. A turn around lane shall be provided for vehicles unable to enter the gated development. Exception: Gates installed on single-family residential property. 5. The design of all culs-de-sac, dead-ends, turn-arounds, and entry or median street curb lines on private drives or gated developments shall be subject to the approval of the fire code official. 6. Road spikes, barbs, or other tire damaging devices shall not be allowed at any gate. 7. All circulation plans for gated developments shall be subject to City Council approval and may require multiple entrances. 8. Adopted City of Edmond standards for streets, sidewalks, fire lanes, fire hydrants, and other engineering requirements shall apply to gated developments. 9. In gated developments the homeowner's association shall be responsible for the following: 9.1. Maintenance and repairs of the private streets and/or fire lanes, and to provide the funds thereof, for the maintenance and repairs through the use of assessments. 9.2. Maintaining a service agreement with a qualified contractor to insure year round maintenance. Contractor is responsible to schedule an annual inspection with the fire code official. 10. The gate opening for a single road used for entrance and exit shall have a clear opening width of not less than 20 feet (6069 mm). Exceptions: 1. The gate openings for dual roads used for separated entrance and exit lanes shall have a clear opening width of not less than 15 feet (4572 mm) on each lane. 2. The gate opening for single-family residential property shall have a clear opening width of not less than 15 feet (4572 mm). 11. An entry keypad shall be located on a pedestal near the normal access route. The access code for non-emergency access shall be given to the Edmond Fire Department. Any change in the code must be reported to the Edmond Fire Department and an acceptance test must be conducted. Exceptions: 1. Manual gates constructed on single-family residential property. 2. Manual gates used for emergency vehicle access. 3. Where approved by the fire code official. 12. A Knox Rapid Entry key switch for emergency access shall be provided at all automatic gates. The switch shall be located in plain view of emergency vehicles and approved by the fire code official. When activated, the switch shall cause all gates to open and stay open until the emergency system is reset by a responsible person. 13. An emergency release hitch pin, shall be installed on the control arm. This hitch pin, when removed, will detach the control arm from the gate(s) and allow the gate(s) to swing open freely to the clear opening width with manual intervention. Exceptions: 1. A Knox Rapid Entry Padlock may be used in lieu of the hitch pin with approval of the fire code official. 2. Emergency release is not required on single-family residential property. 14. A battery back-up system shall be provided for all automatic gates. These batteries shall be trickle charged to maintain electrical energy, and in the event of loss of normal electrical current cause all gates to open and remain open until reset by a responsible person or the return of electrical power. 15. The location of all entrance pedestals, Knox Rapid Entry switches, key pads, hitch pins, related equipment, signage, and the opening design, swinging or sliding operation of the gate or any other design specification shall be constructed and installed in accordance with the plans approved by the fire code official. 16. Electric gate operators, where provided, shall be listed in accordance with UL 325. Exception: Gates constructed on single-family residential property. 17. Gates intended for automatic operation shall be designed, constructed and installed to comply with the requirements of ASTM F2200. Exception: Gates constructed on single-family residential property. 18. The minimum paving width for all lanes entering and exiting any development shall be not less than 20 feet (6096 mm) in width. There shall be no parking on said 20 foot (6096 mm) roadway, and appropriate signage shall be provided. If parking is requested on the roadway the minimum width shall be 26 feet (7925 mm). 19. Should any problem occur in the operation of the gate or any violation of any section of this code should occur, the gate shall remain open and accessible until the problem is resolved and/or the gate is repaired and tested. 20. An access agreement between the developer, homeowner's association or other responsible property owner and the City of Edmond shall be approved by the fire code official. A copy of this agreement shall be kept on file with the Edmond Fire Department. The agreement shall contain the installation contractor's name, address and 24-hour-a-day contact information. The agreement shall also contain the name of the developer, homeowner's association representative or other responsible property owner, address, and 24-hour-a-day contact information.

(Ord. 3365, § 2, December 10, 2012).

Ask a question about Edmond law

Corpus searches the Edmond sections it holds and shows the ones that match, with their citations. Free, no sign-in.