Sec. 43-194. - Cleaning schedule.

Grease interceptors, oil/water separators, grit traps, and grinder pumps shall be cleaned as often as necessary to ensure that sedimentation and floating debris does not accumulate to impair the efficiency of the grease interceptor, oil/water separator, grit trap, and grinder pump, and to ensure that the discharge is in compliance with local discharge limits and no visible grease or debris larger than one-half (½) inch is observable in the discharge. (1) All in use grease interceptors shall be serviced and completely pumped of accumulated waste content when the twenty-five (25) percent rule is reached. The twenty-five (25) percent rule shall be the primary method used to determine cleaning schedules. However, a minimum service schedule for grease interceptors less than one thousand (1,000) gallons or engineer approved equivalent shall not exceed ninety (90) calendar days. For grease interceptors greater than or equal to one thousand (1,000) gallons or engineer approved equivalent, the minimum service schedule shall not exceed one hundred eighty (180) calendar days. At any point in time if solidification occurs, the twenty-five (25) percent rule is met or exceeded, or waste backs up into the grease interceptor occurs, servicing of the interceptor is to be conducted immediately at the facilities expense. All devices shall be inspected for damages by the transporter/self-cleaner every time they are serviced. (2) At the discretion of the public works director or designee, grease interceptors that will be out of use for longer than thirty (30) days will not be required to be cleaned again until placed back into service. Prior to being taken out of service, interceptors shall be pumped dry of all contents, and refilled with clean water. Once placed back in service, the interceptor is subject to the above schedule. Generators shall receive written permission from line maintenance, prior to removing the interceptor from service and its regular cleaning schedule. (3) Grease interceptors shall be kept free of inorganic solid materials such as grit, rocks, gravel, sand, eating utensils, straws, sauce packages, cigarettes, shells, towels, rags, etc., which could thereby reduce the effective volume of the device. (4) Oil/water separators shall be serviced and completely pumped of accumulated waste content when the twenty-five (25) percent rule is reached or at a minimum of three hundred sixty five (365) calendar days, whichever first occurs. If a car wash has a water reclamation system in use, the first two (2) to three (3) compartments shall be completely pumped of accumulated waste when the twenty-five (25) percent rule is reached or every six (6) months, whichever first occurs. All of the chambers shall be completely emptied and cleaned at a minimum of three hundred sixty-five (365) calendar days. (5) The public works director or designee has the authority to increase the cleaning schedules as necessary.

(Ord. No. 3150, §§ 1, 2, 7-12-11; Ord. No. 3402, § 1, 2-11-20)

Ask a question about Midwest City law

Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.