§ 43-421 — Existing facilities required to obtain permit
Code of Ordinances of the City of Midwest City, Oklahoma (Codified through Ordinance No. 3615, enacted November 13, 2025. (Supp. No. 21)) · Midwest City Code of Ordinances § 43-421
Corpus is an independent public-information project, not the official City of Midwest City website. Stable reference: corpuslaw.us/code/ddbc5999-f544-4c1e-bb05-9caad0eb16ac
Sec. 43-421. - Existing facilities required to obtain permit.
(a) Any existing industrial, commercial, institutional or multifamily or group residential facilities that discharge stormwater into the MS4 or community waters and have been issued any of the Standard Industrial Classification codes listed will be required to develop a pollution prevention plan and apply for an industrial stormwater discharge permit. The industrial stormwater discharge permit shall be required in addition to any permits required by EPA, state, or city. SIC Code | Title 10 | Metal Mining 12 | Coal Mining 13 | Oil & Gas Extraction 14 | Nonmetallic Minerals, Except Fuels 20 | Food and Kindred Products 21 | Tobacco Products 22 | Textile Mill Products 23 | Apparel and Other Textile Products 24 | Lumber and Wood Products 25 | Furniture and Fixtures 26 | Paper and Allied Products 27 | Printing and Publishing 28 | Chemicals and Allied Products 29 | Petroleum and Coal Products 30 | Rubber and Miscellaneous Plastic Products 31 | Leather and Leather Products (except 311) 32 | Stone, Clay, and Glass Products 33 | Primary Metal Industries 34 | Fabricated Metal Products 35 | Industrial Machinery and Equipment 36 | Electronic and Other Electric Equipment 37 | Transportation Equipment 38 | Instruments and Related Products 39 | Miscellaneous Manufacturing Industries 40 | Railroad Transportation 41 | Local and Interurban Passenger Transit 42 | Trucking and Warehousing 43 | United States Postal Service 44 | Water Transportation 45 | Transportation by Air 5015 | Motor Vehicle Parts, Used 5093 | Scrap and Waste Materials 5171 | Petroleum Bulk Stations and Terminals 55 | Automotive Dealers and Gasoline Service Stations 58 | Eating and Drinking Places 75 | Automotive Repair, Services and Parking 82 | Educational Services A request for a no exposure certification (NEC) may be made in lieu of an industrial stormwater discharge permit. Upon request for a NEC, an inspection of the facility will be performed by the manager. If a NEC is issued, the facility will be exempt from requirements of the industrial stormwater discharge permit for a period of five (5) years from date of issue. All facilities that have been issued a NEC will be subject to an annual compliance inspection. If during the annual inspection it is determined, the facility no longer qualifies for a NEC, then an application for an industrial stormwater discharge permit must be submitted. (b) An application, including a pollution prevention plan, shall be submitted to the manager. Upon approval, an industrial stormwater discharge permit shall be issued within six (6) months of the submittal of the pollution prevention plan. Any approved pollution prevention plan shall be incorporated into the industrial stormwater discharge permit. The industrial stormwater discharge permit may require the facility to implement structural and nonstructural best management practices to reduce pollution discharge. If the application is not approved, the manager shall notify the applicant of the deficiencies. The applicant shall have ninety (90) days to revise and re-submit the application. If the deficiencies noted by the manager are not corrected and the application re-submitted for approval within the ninety (90) days or, if after being re-submitted, is disapproved, any discharge of stormwater after that date into waters of the community shall be unlawful. Once issued, an industrial stormwater discharge permit shall be valid for five (5) years, unless sooner revoked for violations of permit conditions, changes in applicable law, changes in discharge or other good cause. (c) The application for an industrial stormwater discharge permit for an existing facility shall include the following: (1) Site map of facility showing buildings, parking, drives, materials loading and access areas, type of each impervious surface, ditches, pipes, catch basins, drainage basin limits, area of facility, acreage of off-site water draining into facility, discharge points to waters of the state or community waters with name of the water or drainage basin. This map will be a minimum of scale of 1" = 100′; (2) Description of facility including the nature of work performed and type of facility; (3) Narrative description of significant materials (as defined at 40 CFR § 122.26) that are currently or in the past have been treated, stored or disposed of at the facility; method of on-site storage or disposal; materials management practices used to minimize contact of these materials with stormwater runoff currently and for the past three (3) years; materials loading and access area; the location and description of existing structural and nonstructural control measures to reduce pollutants in stormwater runoff; and a description of any treatment the stormwater receives; (4) Cleanup schedule for debris, material storage areas, garbage storage or disposal areas, or other areas that have the potential to pollute stormwater; (5) Description of plan of instruction to employees at all levels in ways to prevent pollution and spill response. The plan shall identify periodic dates for such training; (6) Name of contact person for permit compliance, including job title, address and phone number; (7) Maintenance schedule of sweeping or vacuuming of facility to prevent washout of a build-up of emissions laden with hydrocarbons, oxides, salts, metals, worn pavement particulates, hydrocarbons for leaks and spills, trash, debris, garbage, metals, tire particles, brake lining particles and various chemicals from the wear, deterioration and deposition of vehicles; (8) Description of other ways the facility plans to implement programs to reduce the discharge of pollutants through stormwater flow. For each area of the facility that generates stormwater discharges associated with an activity with a reasonable potential for containing significant amounts of pollutants, a prediction of the direction of flow and an estimate of the types of pollutants which are likely to be present in stormwater discharges associated with industrial activity; (9) Plans showing the construction of an appropriately sized grit sediment basin and oil skimmer structure for discharge outfalls into community waters in accordance with detailed drawings of these structures which are shown in the Stormwater Management Section Best Management Practices Manual; (10) A record of available sampling data describing pollutants in stormwater discharges; (11) A preventative maintenance program that includes regular inspection and maintenance of stormwater management devices (e.g., cleaning grit chambers, catch basins) as well as inspecting and testing plant equipment and systems to uncover conditions that could cause breakdowns or failures resulting in discharges of pollutants to surface waters; and (12) Designation of a person to keep a record of incidents such as significant spills or other discharges that materially affect stormwater, along with other information describing the quality and quantity of stormwater discharges. Inspections and maintenance activities shall be documented and recorded.
(Ord. No. 2842, § 4, 5-28-02; Ord. No. 3186, § 3, 1-8-13)
Ask a question about Midwest City law
Corpus searches the Midwest City sections it holds and shows the ones that match, with their citations. Free, no sign-in.