§ 2.4.90 — General Land Division Standards
Municipal Code of the City of Corvallis, Oregon (Codified through Ordinance No. 2026-31, enacted October 19, 2026. (Supp. No. 70, Update 2)) · Corvallis Land Development Code § 2.4.90
Corpus is an independent public-information project, not the official City of Corvallis website. Stable reference: corpuslaw.us/code/043515cf-82b8-4205-8a1a-90a66e934be5
Section 2.4.90 - General Land Division Standards.
2.4.90.01 Applicability. In addition to the review criteria in Section 2.4.60.06, all Tentative Plats must comply with the following standards. 2.4.90.02 General Requirements. a. All subdivision and partition proposals must comply with state regulations in Oregon Revised Statute (ORS) Chapter 92 Subdivisions and Partitions. b. Plat Boundary and Remaining Units of Land - Land divisions must include the entire parent unit of land in the surveyed boundary of the Subdivision or Partition. Each unit of land created must be a Lot, Parcel or Tract. Remaining portions of the parent unit of land that extend outside the surveyed boundary are not allowed. c. Urban Conversion Plan For Large Lots - The Applicant is required to provide an urban conversion plan when dividing land into large lots, parcels or tracts that have potential for future further Subdivision or Partition based on density allowances of the zone. The conversion plan must show street extensions, utility extensions, and lot/parcel patterns to indicate how the property may be developed to Comprehensive Plan densities and to demonstrate that the proposal will not inhibit development of adjacent lands. The conversion plan must also demonstrate consistency with the following: 1. block perimeter requirements of Sections 4.0.30.b (Pedestrian Block Perimeter) and 4.0.60.o (Vehicle Block Perimeter) of Chapter 4.0 - Improvements Required with Development, if the parent unit of land is greater than two acres in size; 2. housing type variation requirements of Section 4.9.80 if the parent unit of land is five acres or greater in size; and 3. Minimum Assured Development Area provisions in Section 4.11.30 for sites containing Natural Hazards and Natural Resources An urban conversion plan is necessary to demonstrate that the tentative plat, in combination with potential future land divisions, complies with the minimum density requirements of the Zone(s) and other standards applicable at time of land division. However, future land divisions on the subject property are not bound to the layout presented with the Urban Conversion Plan, with the exception that Minimum Assured Development Area may not be re-used as described in Section 4.11.30.c. 2.4.90.03 Block Standards. a. General - Length, width, and shape of blocks are based on the minimum lot area requirements of the zone and street width and circulation standards in Chapter 4.0 Improvements Required with Development. b. Size - Blocks will be sized in accordance with the standards in Sections 4.0.30.b (Pedestrian Block Perimeter) and 4.0.60.o (Vehicle Block Perimeter) of Chapter 4.0 - Improvements Required with Development. c. Public Access Easements for Pedestrian Facilities - The applicant must grant a public access easement on the Final Plat consistent with the pedestrian facility requirements in Section 4.0.30.b and 4.0.30.c. 2.4.90.04 Lot and Parcel Standards. The Applicant must number each Lot and Parcel consecutively. Lots and Parcels must meet the requirements of the applicable Zone as follows: a. Width - The minimum Lot width will be as required by the applicable zone. b. Area - 1. Partitions - each Parcel must comply with the Minimum Lot Area, if specified in the Zone. Exception: For Flag Parcels, the area will be as required by the applicable Zone and must be provided entirely within the buildable site area, exclusive of any Accessway. See Figure 2.4-2 Lot Area Exclusive of Accessway, below. [image omitted; see the official code] Figure 2.4-2 - Lot Area Exclusive of Accessway 2. Subdivisions - each Lot must comply with the Minimum Lot Area, if specified in the Zone. c. Side Lot Lines - Side Lot and Parcel lines must be at right angles to the street the Lots and Parcels face when possible. d. Any opposing or parallel Lot/Parcel lines must be separated by a minimum distance of 15 feet. For opposing or parallel Lot/Parcel lines that form the boundaries of a Flag Parcel accessway, the distance must be increased or decreased as specified in Section 2.4.90.08. e. Existing Structures: The boundary of each newly created Lot and Parcel must be placed to avoid creating a Nonconforming Structure. See Chapter 1.4. 2.4.90.05 Through Lots. Applicants must avoid creating Through Lots through a Land Division process except where essential to overcome specific disadvantages of topography and orientation. When Through Lots in low density residential zones are created through a Land Division process, the Applicant must comply with the following standards: a. A 1-feet wide Vehicular Non-Access Easement area must be provided along the full length of the lot's frontage abutting the higher classification street, and shown on the plat. If both frontages abut the same classification of street, the location of the Vehicular Non-Access Easement will be as determined by the City Engineer. b. No vehicular access will be permitted within or through the Vehicular Non-Access Easement area. 2.4.90.06 Tracts. When provided, the applicant must identify each Tract with a letter (example: Tract A). The plat must clearly identify the purpose(s) for the Tract and the party or parties responsible for maintaining the Tract. See definition of Tract in Section 1.6.30. The boundary of each newly created Tract must be placed to avoid creating a Nonconforming Structure. See Chapter 1.4. 2.4.90.07 Access and Minimum Street Frontage. a. To ensure sufficient space is provided for required pedestrian facilities, utilities, street trees, emergency vehicle access, and (where applicable) on-street vehicle parking, each lot and parcel must abut a street for a distance of at least 20-ft. unless it complies with the exceptions listed in "1" or "2" below. 1. On a lot or parcel zoned RS-6 or RS-9 and existing prior to December 31, 2006, an Applicant may use a Partition to create Flag Parcels that satisfy all of the following criteria: a) Each resulting parcel must contain an area equal to no more than 175 percent of the zone's minimum lot area for a Single Detached dwelling; b) No provision of the Code requires a street through any part of the site per Section 4.0.60; and c) The Applicant must provide Accessways that satisfy Section 2.4.90.08 requirements, below. 2. The lot or parcel adjoins a public or private alley. The alley must comply with Section 4.0.60.j and be installed or financially secured by the applicant prior to final plat. b. For lots and parcels within the Climate-Friendly Areas (CFA) Overlay having a front lot line with a dimension less than 50 feet, direct vehicular access is limited to alleys in accordance with "1" below. For lots and parcels outside of the CFA Overlay having a front lot line with a dimension less than 50 feet, proposed off-street vehicle parking must comply with one of the following options: 1. Alley Access: Vehicular access is limited to a public or private alley adjoining the side or rear property line. The alley must comply with Section 4.0.60.j and be installed or financially secured by the applicant prior to final plat. Additionally, the applicant provides a deed restriction that applies to the lot or parcel, limiting vehicular access to the adjoining alley. The Applicant must record the deed restriction concurrently with the final plat. 2. Shared Driveway: Vehicular access is shared between two adjoining lots or parcels. The width of the shared driveway may not exceed 20 feet, for that portion between the street and five feet interior to the front property line. The applicant must grant a reciprocal access and utility easement as part of the land division. The Applicant must provide deed restrictions that apply to the lots or parcels, noting the requirement for shared access and limit on driveway pavement width. The Applicant must record the deed restriction concurrently with the Final Plat. Additionally, the shared driveway and easement is placed to allow a minimum of 20 feet of uninterrupted curb along the frontage of the adjoining lots or parcels. 3. Shared Parking Area: Vehicle parking is provided in a shared common area Tract containing up to eight spaces. The shared parking area must not be placed between buildings and the streets to which those buildings are primarily oriented. The Tract must abut one or more of the lots or parcels it serves and must be located interior to the Block. c. Vehicular access is not required to a lot, parcel, or tract, except where the Fire Code requires it. 1. For each proposed lot, parcel, and tract where vehicle Access is proposed, the Access must comply with the standards in Sections 4.0.60.q, 4.1.30, 4.2.30.b.3, City Site Development Design Standards, Engineering Standards, and the Transportation System Plan. Where necessary to comply, driveway locations must be consolidated and the Applicant must grant reciprocal access easements for shared driveways consistent with Section 2.4.90.10. See definition of Access and Frontage in Section 1.6.30. 2. For each proposed lot, parcel, and tract where vehicle Access is not proposed, a 1 foot-wide Vehicular Non-Access Easement area must be provided along the full length of the frontage, and shown on the plat. 2.4.90.08 Accessways for Flag Parcels. a. For Partitions containing Flag Parcels, an Applicant may reduce and combine access requirements of Section 2.4.90.07 to provide an Accessway or combination of Accessways, in accordance with the standards in Table 2.4-1. See definition of Accessway in Section 1.6.30. Table 2.4-1 Accessway Width Requirements Number of Parcels Served | Minimum Combined Width of Reciprocal Access and Utility Easement | Minimum Accessway Width Per Parcel 1 | n/a | 17 feet 2 (Accessway connecting to Local Street) | 23 feet | 11.5 feet 2 (Accessway connecting to Neighborhood Collector, Collector or Arterial Street) | 25 feet | 12.5 feet 3 | 25 feet | 8.33 feet When combined, Accessways and the associated Reciprocal Access and Utility Easement may not serve more than three parcels. Combined Accessways that provide fire access must be a minimum of 25 feet wide. If a fire hydrant is required to be located along the Accessway, the minimum width must be 31 feet. Accessways are not required to contain a paved vehicular access, unless required for emergency access. b. Accessways must connect to a public or private street. The Director may allow an exception to the paving requirements for the existing dedicated right-of-way if the proposed Partition meets all of the following conditions: 1. The Accessway connects to a paved street that is a minimum of 20 feet wide; 2. The Accessway serves a single parcel and not more than four dwelling units; 3. The property owner signs an irrevocable petition for public street improvements and records it with the property through the Benton County Recorder's Office; and 4. The property owner demonstrates that the grade of the property will allow foundation drainage to be carried by gravity, without pumping, to a public storm drain or other drainage facility approved by the City Engineer. 2.4.90.09 Public, Private, and Franchise Utilities. The Applicant must provide public and franchise utilities per Chapter 4.0. Private utilities such as sewer, water and stormwater laterals that cross property lines must be contained within private easements declared with the Final Plat. 2.4.90.10 Reciprocal Access and Utility Easements. If an Accessway or common driveway serves more than one lot or parcel, the applicant must grant for the benefit of the owners of the created parcels or lots, a reciprocal access and utility easement to ensure access rights for ingress, egress, and private utility maintenance. The width of the reciprocal access and utility easement for an Accessway must comply with the dimensional standards in Section 2.4.90.08 and Table 2.4-1. The width of the reciprocal access and utility easement for a common driveway not located within a Flag Parcel Accessway must comply with the minimum driveway paving width and vehicle maneuvering standards contained in the City's Site Development Design Standards. 2.4.90.11 Preservation of Natural Features and Site Development Prior to Final Plat. Construction of public and private infrastructure necessary to serve lots or parcels created through a Land Division often occurs prior to recording the Final Plat. For properties with Natural Resources or Natural Hazards, site development activities that occur prior to recording the Final Plat must comply with the provisions associated with preservation or protection of Natural Features contained in Article IV of this Code. Additionally: a. Excavation and grading must conform to Chapter 4.14 - Landslide Hazard and Hillside Development Provisions; and the City's Erosion Prevention and Sediment Control Manual. b. For Development Sites containing mapped or unmapped Special Flood Hazard Area as described in Section 4.5.20.01, the applicant must obtain approval of a Floodplain Development Permit, prior to Final Plat. c. Minimum Assured Development Area - For property with Natural Resources or Natural Hazards, proposed Land Divisions must demonstrate compliance with the Minimum Assured Development Area (MADA) provisions of Section 4.11.30. d. Where required by the provisions of Chapter 4.5 - Floodplain Provisions, Chapter 4.12 - Significant Vegetation Protection Provisions, Chapter 4.13 - Riparian Corridor and Wetland Provisions, or Chapter 4.14 - Landslide Hazard and Hillside Development Provisions; the applicant must grant on the Final Plat, Tracts or Conservation Easements delineating Protected and Preserved Areas.
(Ord. No. 2022-12, eff. 6-1-2022; Ord. No. 2023-19, §§ 6, 7(Exh. A), eff. 6-30-2023; Ord. No. 2023-27, 3(Exh. A), eff. 2-28-2024; Ord. No. 2025-25, § 5(Exh. A), eff. 6-12-2025; Ord. No. 2025-31, § 5(Exh. A), 7-21-2025)
Ask a question about Corvallis law
Corpus searches the Corvallis sections it holds and shows the ones that match, with their citations. Free, no sign-in.